Changes for page MTCA ADCs

Last modified by sndueste on 2024/07/08 09:50

From version 5.1
edited by sndueste
on 2019/08/22 15:52
Change comment: There is no comment for this version
To version 1.1
edited by sendels
on 2019/05/09 14:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.sndueste
1 +XWiki.sendels
Content
... ... @@ -1,147 +1,0 @@
1 -=== General info ===
2 -
3 -\\
4 -
5 -* [[ADQ412 server description~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/FLASHWiki/Wiki.jsp?page=SPdevicesDMA%20ADQ||shape="rect"]]
6 -* [[more ADC server descriptions~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp#section-C_2B_2B+Server+Interface-D_ADCscope?page=C%2B%2B%20Server%20Interface||shape="rect"]]
7 -* [[Description of the DAQ properties related to the ADCs~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp#section-C_2B_2B+Server+Interface-DaqfedConfiguration.?page=C%2B%2B%20Server%20Interface||shape="rect"]]
8 -* [[ a collection of usefull things related to the OPIS ADCs>>doc:FLASH.OPIS ADC related things]]
9 -
10 -\\
11 -
12 -=== Our ADC cards ===
13 -
14 -\\
15 -
16 -==== SP-Devices ADQ412AC ====
17 -
18 -We have ADQ412AC-4G-MTCA digitizer cards for the experiment crates (Exp1, Exp2 and FL2Exp1):
19 -[[ADQ412_datasheet.pdf>>attach:10-0494_C_ADQ412_datasheet.pdf]] ( [[new version>>attach:10-0494-adq412_datasheet.pdf]], [[sampling rates table>>attach:Clocking_AppNote.pdf]])
20 -The cards are connected via Patch panels to the Experimental endstations.
21 -
22 -\\
23 -
24 -* **NOTE: between ADC and Patch panel we have installed an [[EMP protector>>attach:EMP_protector.pdf]] and an additional 1dB attenuator**
25 -* for the influence of the Patch cable and the EMP protector see also [[this logbook entry~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://ttfinfo.desy.de/ExpHallelog/show.jsp?dir=/2016/27/08.07&pos=2016-07-08T17:41:07||shape="rect"]]
26 -* we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs. The available ADCs
27 -* 5x, 10x, 20 x 50x and 100x
28 -* And the  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
29 -
30 -\\
31 -
32 -(% class="wrapped" %)
33 -|(((
34 -Impedance AC
35 -)))|(((
36 -50 OHM
37 -)))
38 -|(((
39 -Input voltage range
40 -)))|=(((
41 -800 mV pp!!!!!!!!!!!!!!!!
42 -)))
43 -|(((
44 -Digitizer resolution
45 -)))|(((
46 -12 bit
47 -)))
48 -
49 -4 CHANNELS MODE
50 -
51 -(% class="wrapped" %)
52 -|(((
53 -Sampling rate
54 -)))|(((
55 -2
56 -)))|(((
57 -GSPS
58 -)))
59 -|(((
60 -Analog bandwidth
61 -)))|(((
62 -2
63 -)))|(((
64 -GHz
65 -)))
66 -
67 -2 CHANNELS MODE
68 -
69 -(% class="wrapped" %)
70 -|(((
71 -Sampling rate
72 -)))|(((
73 -4
74 -)))|(((
75 -GSPS
76 -)))
77 -|(((
78 -Analog bandwidth
79 -)))|(((
80 -1.3
81 -)))|(((
82 -GHz
83 -)))
84 -
85 -\\
86 -
87 -===== ADC and DOOCS / DAQ =====
88 -
89 -The HDF5 names for the ADC traces are depending on the beamline :
90 -\\PG Beamline:
91 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH00/TD{{/code}}
92 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH01/TD{{/code}}
93 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH02/TD{{/code}}
94 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH03/TD{{/code}}
95 -
96 -BL Beamlines:
97 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH00/TD{{/code}}
98 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH01/TD{{/code}}
99 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH02/TD{{/code}}
100 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH03/TD{{/code}}
101 -\\{{code language="none"}}/FL1/Experiment/BL2/ADQ412 GHz ADC/CH00/TD{{/code}}
102 -{{code language="none"}}/FL1/Experiment/BL2/ADQ412 GHz ADC/CH01/TD{{/code}}
103 -\\{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH02/TD{{/code}}
104 -{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH03/TD{{/code}}
105 -
106 -DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
107 -here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is actvated the {{code language="none"}}CH00.DAQ.TD{{/code}} contins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ...
108 -DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}}
109 -
110 -in addition there are also additional parameters saved like:
111 -
112 -* sample frequency (in MHz)
113 -* error (state)
114 -* offset
115 -
116 -\\
117 -
118 -==== Struck SIS8300-L2D ====
119 -
120 -There is one in each of the MTCAs in the hall: MTCA-EXP1 at PG/BL1, the other at BL2 and BL3.
121 -
122 -They are 16 bit, 10 channel, 125 MS/s ADCs.
123 -
124 -\\
125 -
126 -* [[User Manual SIS8300-L2 ADC ACM>>attach:sis8300l2-m-x009-1-v101.pdf]]
127 -* [[User Manual SIS8900 RTM>>attach:sis8900-m-1-1-v104.pdf]]
128 -
129 -50 Ohm input impedance, -1 V,...,+1 V default input range, analog signals can be routed to AC and DC input stage. The coupling is DC via op-amp (switching to AC transformer involves resoldering of SMD solder bridges).
130 -
131 -Here is a trace of the first signal, a 1 MHz trigger connected from the x2timer board in the same MTCA:
132 -
133 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/adc_mhz.jpg~|~|alt="adc_mhz.jpg" width="550" height="500"~]~]>>attach:adc_mhz.jpg]]
134 -
135 -\\
136 -
137 -==== Using the Struck SIS8300-L2D to detect only integrated values of pulses ====
138 -
139 -FS-LA (Falko Peters) programmed a pulse detection server that automatically detects peaks in the signel and integrates the samples around the peak. <\br> things to set:
140 -
141 -* Peak height: from what signal on (incounts) is the signal to be counted as peak
142 -* pre and post peak integration time: how much ns to be integrated before and after the peak sample that are taken into account for the peak
143 -* pre and post peak noise time: before and after the samples that are taken for the actual signal these samples are used as background ( they also can be used to define the "deadtime" of the detector before it searches for new peaks.
144 -
145 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" width="400" height="300"~]~]>>attach:pulse_energy_server.jpg]]
146 -
147 -\\