Changes for page MTCA ADCs

Last modified by sndueste on 2024/07/08 09:50

From version 5.1
edited by sndueste
on 2019/08/22 15:52
Change comment: There is no comment for this version
To version 9.1
edited by sndueste
on 2019/10/21 15:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,13 @@
1 -=== General info ===
1 +Content:
2 2  
3 -\\
4 4  
4 +
5 +{{toc/}}
6 +
7 +----
8 +
9 += General info =
10 +
5 5  * [[ADQ412 server description~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/FLASHWiki/Wiki.jsp?page=SPdevicesDMA%20ADQ||shape="rect"]]
6 6  * [[more ADC server descriptions~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp#section-C_2B_2B+Server+Interface-D_ADCscope?page=C%2B%2B%20Server%20Interface||shape="rect"]]
7 7  * [[Description of the DAQ properties related to the ADCs~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp#section-C_2B_2B+Server+Interface-DaqfedConfiguration.?page=C%2B%2B%20Server%20Interface||shape="rect"]]
... ... @@ -9,23 +9,22 @@
9 9  
10 10  \\
11 11  
12 -=== Our ADC cards ===
18 += Our ADC cards =
13 13  
14 -\\
20 +== GHz ADCs: SP-Devices ADQ412AC ==
15 15  
16 -==== SP-Devices ADQ412AC ====
17 -
18 18  We have ADQ412AC-4G-MTCA digitizer cards for the experiment crates (Exp1, Exp2 and FL2Exp1):
19 19  [[ADQ412_datasheet.pdf>>attach:10-0494_C_ADQ412_datasheet.pdf]] ( [[new version>>attach:10-0494-adq412_datasheet.pdf]], [[sampling rates table>>attach:Clocking_AppNote.pdf]])
20 -The cards are connected via Patch panels to the Experimental endstations.
24 +The cards are connected via Patch panels to the Experimental endstations and can be operated with a jddd panel:
21 21  
26 +[[image:attach:image2019-10-21_15-21-23.png||width="800"]]
27 +
22 22  \\
23 23  
30 +\\
31 +
24 24  * **NOTE: between ADC and Patch panel we have installed an [[EMP protector>>attach:EMP_protector.pdf]] and an additional 1dB attenuator**
25 25  * for the influence of the Patch cable and the EMP protector see also [[this logbook entry~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://ttfinfo.desy.de/ExpHallelog/show.jsp?dir=/2016/27/08.07&pos=2016-07-08T17:41:07||shape="rect"]]
26 -* we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs. The available ADCs
27 -* 5x, 10x, 20 x 50x and 100x
28 -* And the  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
29 29  
30 30  \\
31 31  
... ... @@ -115,8 +115,17 @@
115 115  
116 116  \\
117 117  
118 -==== Struck SIS8300-L2D ====
123 +== Amplifiers for the GHZ ADCs ==
119 119  
125 +* **we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers** to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs.
126 +* The available ADCs 5x, 10x, 20 x 50x and 100x
127 +* The ADCs can be borrowed from Markus Braune
128 +* The Amplifiers fot perfectly to the dynamic range of the GHz ADCs - here a  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
129 +
130 +\\
131 +
132 +== 108 MHz ADCs:  Struck SIS8300-L2D ==
133 +
120 120  There is one in each of the MTCAs in the hall: MTCA-EXP1 at PG/BL1, the other at BL2 and BL3.
121 121  
122 122  They are 16 bit, 10 channel, 125 MS/s ADCs.
... ... @@ -134,7 +134,7 @@
134 134  
135 135  \\
136 136  
137 -==== Using the Struck SIS8300-L2D to detect only integrated values of pulses ====
151 +== Pulse energy server: Using the Struck SIS8300-L2D to detect only integrated values of pulses ==
138 138  
139 139  FS-LA (Falko Peters) programmed a pulse detection server that automatically detects peaks in the signel and integrates the samples around the peak. <\br> things to set:
140 140