Changes for page Trigger Howto

Last modified by sndueste on 2023/07/07 11:28

From version 19.1
edited by sndueste
on 2020/01/23 09:29
Change comment: There is no comment for this version
To version 20.1
edited by sndueste
on 2020/01/23 12:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -25,7 +25,7 @@
25 25  
26 26  \\
27 27  
28 -\\
28 +[[image:attach:image2020-1-23_12-10-59.png||width="700"]]
29 29  
30 30  \\
31 31  
... ... @@ -35,78 +35,8 @@
35 35  
36 36  \\
37 37  
38 -= Different trigger events (starting points) =
39 -
40 -one can configure each channel for an individual trigger event
41 -
42 -**FLASH1**
43 -
44 -(% class="wrapped" %)
45 -|(((
46 -trigger No
47 -)))|(((
48 -function
49 -)))
50 -|(((
51 -16
52 -)))|(((
53 -the MCA trigger 3.11 ms before the Flash1 pulses (same as A6 but more stable)
54 -)))
55 -|(((
56 -166
57 -)))|(((
58 -A6 event. still possible to use but less precise than 16
59 -)))
60 -|(((
61 -162
62 -)))|(((
63 -A2 event as earliest ( 24 ms before the FEL)
64 -)))
65 -|(((
66 -224
67 -)))|(((
68 -E0 event of the BL fast shutter ( 19 ms before the FEL)
69 -)))
70 -|(((
71 -225
72 -)))|(((
73 -E1 event of the PG fast shutter ( 19 ms before the FEL)
74 -)))
75 -|(((
76 -21
77 -)))|(((
78 -Trig16 + first bunch of FLASH1 - this trigger is shifted when FL1 starts later than "700"
79 -)))
80 -
81 81  \\
82 82  
83 -\\
84 -
85 -**FLASH2**
86 -
87 -(% class="wrapped" %)
88 -|(((
89 -trigger No
90 -)))|(((
91 -function
92 -)))
93 -|(((
94 -22
95 -)))|(((
96 -Trig116 + first bunch of FLASH2 - this trigger is shifted when FL2 starts at a different start time
97 -)))
98 -|(((
99 -181
100 -)))|(((
101 -shifts with the start time of FLASH2 as event 22 but comes 22 ms ! before the FEL
102 -)))
103 -
104 -from this trigger as starting point one can shift the timing in 9 ns steps first and finally in 0.9 ns steps for fine adjustment.
105 -
106 -\\
107 -
108 -\\
109 -
110 110  = Expert panels =
111 111  
112 112  \\
... ... @@ -279,10 +279,77 @@
279 279  
280 280  \\
281 281  
212 += Different trigger events (starting points) =
213 +
214 +one can configure each channel for an individual trigger event
215 +
216 +**FLASH1**
217 +
218 +|(((
219 +trigger No
220 +)))|(((
221 +function
222 +)))
223 +|(% colspan="1" %)(((
224 +21
225 +)))|(% colspan="1" %)(((
226 +Trig16 + first bunch of FLASH1 - this trigger is shifted when FL1 starts later than "700"
227 +)))
228 +|(% colspan="1" %)(((
229 +180
230 +)))|(% colspan="1" %)(((
231 +shifts with the start time of FLASH1 as event 21 but comes 23 ms  before the FEL
232 +)))
233 +|(((
234 +16
235 +)))|(((
236 +the MCA trigger 3.11 ms before the Flash1 pulses (same as A6 but more stable)
237 +)))
238 +|(((
239 +166
240 +)))|(((
241 +A6 event. still possible to use but less precise than 16
242 +)))
243 +|(((
244 +162
245 +)))|(((
246 +A2 event as earliest ( 24 ms before the FEL)
247 +)))
248 +|(((
249 +224
250 +)))|(((
251 +E0 event of the BL fast shutter ( 19 ms before the FEL) - to be switched off in 2020
252 +)))
253 +|(((
254 +225
255 +)))|(((
256 +E1 event of the PG fast shutter ( 19 ms before the FEL) - to be switched off in 2020
257 +)))
258 +
282 282  \\
283 283  
284 284  \\
285 285  
263 +**FLASH2**
264 +
265 +|(((
266 +trigger No
267 +)))|(((
268 +function
269 +)))
270 +|(((
271 +22
272 +)))|(((
273 +Trig116 + first bunch of FLASH2 - this trigger is shifted when FL2 starts at a different start time
274 +)))
275 +|(((
276 +181
277 +)))|(((
278 +shifts with the start time of FLASH2 as event 22 but comes 23 ms  before the FEL
279 +)))
280 +
281 +from this trigger as starting point one can shift the timing in 9 ns steps first and finally in 0.9 ns steps for fine adjustment.
282 +
286 286  \\
287 287  
288 288  \\
... ... @@ -290,3 +290,13 @@
290 290  \\
291 291  
292 292  \\
290 +
291 +\\
292 +
293 +\\
294 +
295 +\\
296 +
297 +\\
298 +
299 +\\