Changes for page Trigger Howto
Last modified by sndueste on 2023/07/07 11:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,31 +25,93 @@ 25 25 26 26 \\ 27 27 28 - [[image:attach:image2020-1-23_12-10-59.png||width="700"]]28 +\\ 29 29 30 30 \\ 31 31 32 32 \\ 33 33 34 - Choosing a FLASH1 trigger there are 2 options to be synchronized with the BL and the PG shutter :34 +\\ 35 35 36 - [[image:attach:image2020-1-23_12-29-40.png||height="250"]]36 +\\ 37 37 38 - Ayellow background indicatesthat the triggeris synchronizedtoa fasthutter:38 += Different trigger events (starting points) = 39 39 40 - [[image:attach:image2020-1-23_12-31-41.png||height="250"]]:[[image:attach:image2020-1-23_12-32-20.png||height="250"]]40 +one can configure each channel for an individual trigger event 41 41 42 +**FLASH1** 43 + 44 +(% class="wrapped" %) 45 +|((( 46 +trigger No 47 +)))|((( 48 +function 49 +))) 50 +|((( 51 +16 52 +)))|((( 53 +the MCA trigger 3.11 ms before the Flash1 pulses (same as A6 but more stable) 54 +))) 55 +|((( 56 +166 57 +)))|((( 58 +A6 event. still possible to use but less precise than 16 59 +))) 60 +|((( 61 +162 62 +)))|((( 63 +A2 event as earliest ( 24 ms before the FEL) 64 +))) 65 +|((( 66 +224 67 +)))|((( 68 +E0 event of the BL fast shutter ( 19 ms before the FEL) 69 +))) 70 +|((( 71 +225 72 +)))|((( 73 +E1 event of the PG fast shutter ( 19 ms before the FEL) 74 +))) 75 +|((( 76 +21 77 +)))|((( 78 +Trig16 + first bunch of FLASH1 - this trigger is shifted when FL1 starts later than "700" 79 +))) 80 + 42 42 \\ 43 43 44 44 \\ 45 45 85 +**FLASH2** 86 + 87 +(% class="wrapped" %) 88 +|((( 89 +trigger No 90 +)))|((( 91 +function 92 +))) 93 +|((( 94 +22 95 +)))|((( 96 +Trig116 + first bunch of FLASH2 - this trigger is shifted when FL2 starts at a different start time 97 +))) 98 +|((( 99 +181 100 +)))|((( 101 +shifts with the start time of FLASH2 as event 22 but comes 22 ms ! before the FEL 102 +))) 103 + 104 +from this trigger as starting point one can shift the timing in 9 ns steps first and finally in 0.9 ns steps for fine adjustment. 105 + 46 46 \\ 47 47 108 +\\ 109 + 48 48 = Expert panels = 49 49 50 50 \\ 51 51 52 -[[image:attach:image20 20-1-23_12-28-6.png||height="250"]] [[image:attach:image2019-9-17_13-8-46.png||height="400"]]114 +[[image:attach:image2019-9-17_13-10-56.png||height="250"]] [[image:attach:image2019-9-17_13-8-46.png||height="400"]] 53 53 54 54 With the **"Expert overview"** one gets the overview over all channels available on the timing card and can configure the card. This is useful to look what channels are using clock settings or burst mode settings that one wants to change ... and using the other tabs one can set parameters for clocks and bursts (see below) 55 55 ... ... @@ -57,7 +57,7 @@ 57 57 58 58 For each trigger channel there is in addition an **"Expert panel"** to set the properties of THIS channel 59 59 60 -[[image:attach:image20 20-1-23_12-28-46.png||height="250"]] [[image:attach:image2019-9-17_13-15-38.png||width="550"]]122 +[[image:attach:image2019-9-17_13-14-52.png||height="250"]] [[image:attach:image2019-9-17_13-15-38.png||width="550"]] 61 61 62 62 \\ 63 63 ... ... @@ -217,79 +217,10 @@ 217 217 218 218 \\ 219 219 220 -= Different trigger events (starting points) = 221 - 222 -one can configure each channel for an individual trigger event 223 - 224 -**FLASH1** 225 - 226 -(% class="wrapped" %) 227 -|((( 228 -trigger No 229 -)))|((( 230 -function 231 -))) 232 -|(% colspan="1" %)((( 233 -21 234 -)))|(% colspan="1" %)((( 235 -Trig16 + first bunch of FLASH1 - this trigger is shifted when FL1 starts later than "700" 236 -))) 237 -|(% colspan="1" %)((( 238 -180 239 -)))|(% colspan="1" %)((( 240 -shifts with the start time of FLASH1 as event 21 but comes 23 ms before the FEL 241 -))) 242 -|((( 243 -16 244 -)))|((( 245 -the MCA trigger 3.11 ms before the Flash1 pulses (same as A6 but more stable) 246 -))) 247 -|((( 248 -166 249 -)))|((( 250 -A6 event. still possible to use but less precise than 16 251 -))) 252 -|((( 253 -162 254 -)))|((( 255 -A2 event as earliest ( 24 ms before the FEL) 256 -))) 257 -|((( 258 -224 259 -)))|((( 260 -E0 event of the BL fast shutter ( 19 ms before the FEL) - to be switched off in 2020 261 -))) 262 -|((( 263 -225 264 -)))|((( 265 -E1 event of the PG fast shutter ( 19 ms before the FEL) - to be switched off in 2020 266 -))) 267 - 268 268 \\ 269 269 270 270 \\ 271 271 272 -**FLASH2** 273 - 274 -(% class="wrapped" %) 275 -|((( 276 -trigger No 277 -)))|((( 278 -function 279 -))) 280 -|((( 281 -22 282 -)))|((( 283 -Trig116 + first bunch of FLASH2 - this trigger is shifted when FL2 starts at a different start time 284 -))) 285 -|((( 286 -181 287 -)))|((( 288 -shifts with the start time of FLASH2 as event 22 but comes 23 ms before the FEL 289 -))) 290 - 291 -from this trigger as starting point one can shift the timing in 9 ns steps first and finally in 0.9 ns steps for fine adjustment. 292 - 293 293 \\ 294 294 295 295 \\ ... ... @@ -297,13 +297,3 @@ 297 297 \\ 298 298 299 299 \\ 300 - 301 -\\ 302 - 303 -\\ 304 - 305 -\\ 306 - 307 -\\ 308 - 309 -\\