... ... @@ -13,6 +13,7 @@
13 13  * signal level is:
14 14  ** + 3 V to + 4.5V  for high (actual trigger)  and  0V for low (baseline) at 50 Ohm
15 15  ** + 6 V to + 9V  for high  and  0V for low at 1 MOhm
16 +** the different trigger levels come from different hardware versions of the trigger hardware ... (4.5 V new, 3 V old)
16 16  ** one can also invert the signal in the expert panel ( thus the base line is + (3-5) V and the actual trigger signal is  0V)
17 17  * The trigger are send to the MTCA several ms before the first FEL pulse (3.1 ms for the "standard" trigger, 21.5 ms for the "early" trigger).
18 18  * The timer card can delay the trigger in 9 ns  steps for more than 100 ms (an option to shift the trigger in 1 ns steps is available in the expert panel)
... ... @@ -325,6 +325,12 @@
325 325  
326 326  \\
327 327  
329 += Some expert infos =
330 +
331 +== how to find details (age ...) of the timer cards / RTMs ==
332 +
333 +[[image:attach:Capture.PNG||height="250"]][[image:attach:Capture1.PNG||height="250"]][[image:attach:Capture2.PNG||thumbnail="true" height="250"]]
334 +
328 328  \\
329 329  
330 330  \\
... ... @@ -332,3 +332,7 @@
332 332  \\
333 333  
334 334  \\
342 +
343 +\\
344 +
345 +\\