Changes for page Trigger Howto
Last modified by sndueste on 2023/07/07 11:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,8 @@ 1 -The MTCA based triggers have a jitter in the few ps range, the delay can be shifted in 1 ns steps (over many ms), one can choose between 10 Hz triggers, frequencies locked to the pulses (e.g. 1MHz) and the actual bunch patterns. A detail led description can be found in [[x2Timer manual>>attach:FLASH.TriggerHowTo@x2Timer.pdf]].And here is the [[little talk>>attach:FLASH.TriggerHowTo@mtca_trigger.pdf]] that was given in the group meeting Oct 20141 +The MTCA based triggers have a jitter in the few ps range, the delay can be shifted in 1 ns steps (over many ms), one can choose between 10 Hz triggers, frequencies locked to the pulses (e.g. 1MHz) and the actual bunch patterns. A detailed description can be found in [[x2Timer manual>>attach:x2Timer.pdf]]. 2 2 3 -in short: the triggers are for low impedance (~~50 OHM terminated ?? ), 5V triggers with an adjustable width. The main controlpan nel for the x2 timer has the control options for the 3 front modules (connected with a RJ45 cable - connecting to a "trigger box" with 2 trigger exits (Lemo) each) and 8 Lemo exits at the back of the crate. in the BL-beamline case these triggers are connected to the BNC (patch pannel) ports at the rack.3 +in short: the triggers are for low impedance (~~50 OHM terminated ?? ), 5V triggers with an adjustable width. The main control panel for the x2 timer has the control options for the 3 front modules (connected with a RJ45 cable - connecting to a "trigger box" with 2 trigger exits (Lemo) each) and 8 Lemo exits at the back of the crate. in the BL-beamline case these triggers are connected to the BNC (patch panel) ports at the rack. 4 4 5 -The main control can be done with a simplified user panel which can hand el the timing in respect to the FEL pulses and not in respect to some (arbitrary) reference time ( Event)[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/TriggerHowto/Trigger_scheme.gif~|~|alt="Trigger_scheme.gif" width="800"~]~]>>attach:Trigger_scheme.gif]]5 +The main control can be done with a simplified user panel which can handle the timing in respect to the FEL pulses and not in respect to some (arbitrary) reference time ( Event)[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/TriggerHowto/Trigger_scheme.gif~|~|alt="Trigger_scheme.gif" width="800"~]~]>>attach:Trigger_scheme.gif]] 6 6 7 7 8 8 \\ ... ... @@ -81,7 +81,7 @@ 81 81 shifts with thestart time of FLASH2 as event 22 but comes 22 ms ! before the FEL 82 82 ))) 83 83 84 -from this trigger as starting point one can shift the timing in 9 ns steps f orst and finally in 0.9 ns steps for fine adjustment.84 +from this trigger as starting point one can shift the timing in 9 ns steps first and finally in 0.9 ns steps for fine adjustment. 85 85 86 86 87 87 [[~[~[image:url:http://hasfweb.desy.de/pub/Setup/TriggerHowto/mtcatrigger1.png~|~|alt="mtcatrigger1.png" width="811" height="532"~]~]>>attach:mtcatrigger1.png]]