Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -140,7 +140,7 @@ 140 140 141 141 \\ 142 142 143 -==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]])/Spectrometer (FLASH1) ====143 +==== Photon Diagnostics SASE / Spectrometer (FLASH1) ==== 144 144 145 145 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 146 146 //always saved (PBD)// ... ... @@ -564,13 +564,15 @@ 564 564 565 565 \\ 566 566 567 - ==== Photon Diagnostics SASE ([[XGMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]] - FLASH2) ====567 +\\ 568 568 569 +==== Photon Diagnostics SASE (XGMD) ==== 570 + 569 569 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 570 570 //always saved (PBD2)// 571 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}}572 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}}573 -desc : calibrated average ( ~~ 20 sec averaging time )SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)573 +DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ 574 +DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ 575 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current) 574 574 units : microJ 575 575 576 576 \\ ... ... @@ -577,12 +577,12 @@ 577 577 578 578 (% style="color: rgb(255,204,0);" %)average Sigma to be included in 579 579 580 - (% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}}(%%)581 - (% style="color: rgb(193,199,208);" %)//always saved (PBD2)//(%%)582 - (% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA(%%)583 - (% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA(%%)584 - (% style="color: rgb(193,199,208);" %)desc :This parameter gives an indicationof the error of the measurement of the average pulse energy. This takes signal to noise, detector resolution, uncertainties in crossectionetc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)585 - (% style="color: rgb(193,199,208);" %)units : microJ582 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} 583 +//always saved (PBD2)// 584 +DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA 585 +DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA 586 +desc : (ion current) 587 +units : microJ 586 586 587 587 \\ 588 588 ... ... @@ -589,10 +589,10 @@ 589 589 \\ 590 590 591 591 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 592 -//always saved (PBD 2)//593 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}594 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}595 -desc : measured in theTunnelinfromtofthegas attenuatorandtheapertures in theHall)594 +//always saved (PBD)// 595 +DOOCS prop : FLASH.FEL/XGM.INTENSITY/FL2.HALL/INTENSITY.TD 596 +DAQ channel: FLASH.FEL/XGM.INTENSITY/FL2.HALL/INTENSITY.TD 597 +desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL 596 596 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 597 597 598 598 \\ ... ... @@ -599,38 +599,60 @@ 599 599 600 600 \\ 601 601 602 -{{code language="none"}}/FL 2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunneluncertainty (sigma){{/code}}603 -//always saved (PBD 2)//604 -DOOCS prop : LASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}}605 -DAQ channel: {{code language="none"}} FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}}606 -desc : (% style="color: rgb(0,0,0);"%)Thisparametergivesanindication of theerrorof themeasurementof thepulseenergy. Thistakessignalto noise, detectorresolution, uncertaintiesin crossectionetcintoaccount. (it is NOT themeasurementofthestatisticalfluctuation of the SASE pulses)(%%)607 -units : a.u. (more or less µJ -related tothe value of the pulse energy)604 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel (raw){{/code}} 605 +//always saved (PBD)// 606 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT14/VAL{{/code}} 607 +DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.FF{{/code}} 608 +desc :Energy per pulse Tunnel (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 609 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 608 608 611 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}} 612 +//always saved (PBD)// 613 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}} 614 +DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}} 615 +desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current) 616 +units : microJ 609 609 610 -{{code language="none"}}{{/code}} 618 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}} 619 +//always saved (PBD)// 620 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}} 621 +DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}} 622 +desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL 623 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 611 611 612 -All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall ! 625 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA (raw){{/code}} 626 +//always saved (PBD)// 627 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT15/VAL{{/code}} 628 +DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}} 629 +desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 630 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 613 613 614 -\\ 632 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}} 633 +//always saved (PBD)// 634 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} 635 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} 636 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, x=horizontal) 637 +units : mm 615 615 616 -Besides pulse energy the GMD also provides information about the beam position 639 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA vertical{{/code}} 640 +//always saved (PBD)// 641 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}} 642 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}} 643 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, y=vertical) 644 +units : mm 617 617 618 -\\ 619 - 620 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel horizontal{{/code}} 621 -//always saved (PBD2)// 622 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}} 623 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}} 624 -desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (tunnel, x=horizontal) 646 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel horizontal{{/code}} 647 +//always saved (PBD)// 648 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}} 649 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}} 650 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, x=horizontal) 625 625 units : mm 626 626 627 -\\ 628 - 629 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel vertical{{/code}} 630 -//always saved (PBD2)// 631 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}} 632 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}} 633 -desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (tunnel, x=horizontal) 653 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel vertical{{/code}} 654 +//always saved (PBD)// 655 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}} 656 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}} 657 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, y=vertical) 634 634 units : mm 635 635 636 636 \\ ... ... @@ -637,70 +637,8 @@ 637 637 638 638 \\ 639 639 640 - 641 -//always saved (PBD2)// 642 -\\\\{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel x DOOCS prop : FLASH.FEL/XGM.BPM/FL2.HALL/X.TDDAQ channel: FLASH.FEL/XGM.BPM/FL2.HALL:2 desc: {{/code}}Besides the well calibrated averaged beam position information there is also the option 643 -{{code language="none"}}to measure the beam position on a single bunch level. HOWEVER this methide needs a perfectly adjusted signal level (talk to your local contact !!) and also then the signal to noise is rather small and one needs some averaging ... BUT with this option one can determine if there was a spatial slope on a burst (say forst bunches were lower than the last ones or so ...)units : mm {{/code}} 644 - 645 -{{code language="none"}}(x=horizontal, y = vertial){{/code}} 646 - 647 -again the same parameter set is available for the **HALL GMD** 648 - 649 649 \\ 650 650 651 -\\ 652 - 653 -==== Photon Diagnostics OPIS[[ >>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]](FLASH2) ==== 654 - 655 -for more info see: [[ OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]] 656 - 657 -(The OPIS hall is not installed yet ...) 658 - 659 -\\ 660 - 661 -{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean photon energy{{/code}} 662 -// saved opon request (PBD2)// 663 -DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}} 664 -DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}} 665 -desc : mean photon energy ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy) 666 -units : eV 667 - 668 -\\ 669 - 670 -{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean wavelength{{/code}} 671 -// saved opon request (PBD2)// 672 -DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}} 673 -DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}} 674 -desc : meanwavelength ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy) 675 -units : nm 676 - 677 -\\ 678 - 679 -{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/number of analyzed bunch (in older version this can be found in OPIS tunnel/Expert stuff/General operation parameters/){{/code}} 680 -// saved opon request (PBD2)// 681 -DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}} 682 -DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}} 683 -desc : The bunch number of the bunch used for the wavelength calculation 684 -units : 685 - 686 -\\ 687 - 688 -If Opis is running typically on the the averaged data is saved. For several experiments it may make sense to save the information for each single bunch. This is up to now done by savng the compleate ADC trace of the TOF setup. This is a huge amount of data and needs processing. This has to be performed after the beamtime in close contact to [[Markus Braune>>mailto:markus.braune@desy.de||shape="rect"]] ( respobsible for [[OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]) 689 - 690 -\\ 691 - 692 -\\ 693 - 694 -\\ 695 - 696 -\\ 697 - 698 -\\ 699 - 700 -\\ 701 - 702 -\\ 703 - 704 704 (% class="wrapped" %) 705 705 |=((( 706 706 DAQ name