Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 18.1
edited by sndueste
on 2019/09/18 10:09
Change comment: There is no comment for this version
To version 23.1
edited by sndueste
on 2019/09/18 16:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -79,7 +79,7 @@
79 79  //always saved (PBD)//
80 80  DOOCS prop : {{code language="none"}}TTF2.FEL/BLFILTERS1/FILTER1/FW.MOTOR.POS{{/code}}
81 81  DAQ channel: {{code language="none"}}TTF2.FEL/BLFILTERS1/FILTER1/FW.MOTOR.POS{{/code}}
82 -desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]]
82 +desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASHUSER.Filter history (BL filterwheel 12)]]
83 83  units: degree
84 84  \\
85 85  
... ... @@ -87,7 +87,7 @@
87 87  //always saved (PBD)//
88 88  DOOCS prop : {{code language="none"}}TTF2.FEL/BLFILTERS2/FILTER2/FW.MOTOR.POS{{/code}}
89 89  DAQ channel: {{code language="none"}}TTF2.FEL/BLFILTERS2/FILTER2/FW.MOTOR.POS{{/code}}
90 -desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]]
90 +desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASHUSER.Filter history (BL filterwheel 12)]]
91 91  units: degree
92 92  \\
93 93  
... ... @@ -137,7 +137,7 @@
137 137  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}}
138 138  DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}}
139 139  desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL
140 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]]
140 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
141 141  
142 142  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel (raw){{/code}}
143 143  //always saved (PBD)//
... ... @@ -144,7 +144,7 @@
144 144  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT14/VAL{{/code}}
145 145  DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.FF{{/code}}
146 146  desc :Energy per pulse Tunnel (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
147 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]]
147 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
148 148  
149 149  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}}
150 150  //always saved (PBD)//
... ... @@ -158,7 +158,7 @@
158 158  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}}
159 159  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}}
160 160  desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL
161 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]]
161 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
162 162  
163 163  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA (raw){{/code}}
164 164  //always saved (PBD)//
... ... @@ -165,13 +165,13 @@
165 165  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT15/VAL{{/code}}
166 166  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}}
167 167  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
168 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]]
168 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
169 169  
170 170  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}}
171 171  //always saved (PBD)//
172 172  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
173 173  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
174 -desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, x=horizontal)
174 +desc :Beam position of the photon Beam determined by the GMD (BDA, x=horizontal)
175 175  units : mm
176 176  
177 177  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA vertical{{/code}}
... ... @@ -178,7 +178,7 @@
178 178  //always saved (PBD)//
179 179  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}}
180 180  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}}
181 -desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, y=vertical)
181 +desc :Beam position of the photon Beam determined by the GMD (BDA, y=vertical)
182 182  units : mm
183 183  
184 184  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel horizontal{{/code}}
... ... @@ -185,7 +185,7 @@
185 185  //always saved (PBD)//
186 186  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}}
187 187  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}}
188 -desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, x=horizontal)
188 +desc :Beam position of the photon Beam determined by the GMD (TUNNEL, x=horizontal)
189 189  units : mm
190 190  
191 191  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel vertical{{/code}}
... ... @@ -192,7 +192,7 @@
192 192  //always saved (PBD)//
193 193  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}}
194 194  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}}
195 -desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, y=vertical)
195 +desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical)
196 196  units : mm
197 197  
198 198  {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}}
... ... @@ -541,13 +541,13 @@
541 541  //always saved (PBD2)//
542 542  DOOCS prop : {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS{{/code}}
543 543  DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS
544 -desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]]
544 +desc: Position of the BL filter wheel 1 - to correlate with the filter material please look **[[here>>doc:FLASHUSER.Filter history (BL filterwheel 12)]]**
545 545  units: degree
546 546  \\
547 547  
548 548  
549 549  //always saved (PBD2)//
550 -\\\\[[here>>doc:FLASH.Filter history (BL filterwheel 12)]]
550 +\\\\**[[here>>doc:FLASHUSER.Filter history (BL filterwheel 12)]]**
551 551  {{code language="none"}}/FL2/Beamlines/Filter wheel/position wheel 2 DOOCS prop : FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS desc: Position of the BL filter wheel 2 - to correlate with the filter material please look units: degree{{/code}}
552 552  
553 553  \\
... ... @@ -589,7 +589,7 @@
589 589  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
590 590  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
591 591  desc : Energy per pulse measured in the Tunnel  (in fromt of the gas attenuator and the apertures in the Hall)
592 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]]
592 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
593 593  
594 594  \\
595 595  
... ... @@ -617,7 +617,7 @@
617 617  //always saved (PBD2)//
618 618  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}}
619 619  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}}
620 -desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (tunnel, x=horizontal)
620 +desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the GMD (tunnel, x=horizontal)
621 621  units : mm
622 622  
623 623  \\
... ... @@ -626,7 +626,7 @@
626 626  //always saved (PBD2)//
627 627  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}}
628 628  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}}
629 -desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (tunnel, x=horizontal)
629 +desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the GMD (tunnel, x=horizontal)
630 630  units : mm
631 631  
632 632  \\
... ... @@ -646,7 +646,7 @@
646 646  
647 647  ==== Photon Diagnostics OPIS[[ >>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]](FLASH2) ====
648 648  
649 -for more info see: [[ OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]
649 +for more info see:** [[ OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]**
650 650  
651 651  (The OPIS hall is not installed yet ...)
652 652  
... ... @@ -810,32 +810,28 @@
810 810  
811 811  \\
812 812  
813 -==== User Data (FLASH1) ====
813 +==== User Data (FLASH2) ====
814 814  
815 +The data saved specifically for detectors at an experiment will show up in /Experiment/ there is a large number of options for cameras or monitoring pslow properties (motor positons etc) for user experiments. For details please ask your local contact.
816 +
817 +NOTE: If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with the DOOCS names
818 +
819 +The most common and permanently installed device used by experiment are our ADCs:
820 +
815 815  ===== GHz ADCs =====
816 816  
817 -ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found [[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]]
823 +ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found** [[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]]**
818 818  //saved on DEMAND in the user DAQ//
819 -\\The HDF5 names for the ADC traces are depending on the beamline :
820 -\\PG Beamline:
821 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH00/TD{{/code}}
822 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH01/TD{{/code}}
823 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH02/TD{{/code}}
824 -{{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH03/TD{{/code}}
825 +\\Up to now there are 4 channels available at FL24
826 +\\\\{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD{{/code}}
827 +{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH01/TD{{/code}}
828 +\\{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH02/TD{{/code}}{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH03/TD{{/code}}
825 825  
826 -BL Beamlines:
827 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH00/TD{{/code}}
828 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH01/TD{{/code}}
829 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH02/TD{{/code}}
830 -{{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH03/TD{{/code}}
831 -\\{{code language="none"}}/FL1/Experiment/BL2/ADQ412 GHz ADC/CH00/TD{{/code}}
832 -{{code language="none"}}/FL1/Experiment/BL2/ADQ412 GHz ADC/CH01/TD{{/code}}
833 -\\{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH02/TD{{/code}}
834 -{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH03/TD{{/code}}
830 +\\
835 835  
836 -DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
832 +DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
837 837  here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} conatins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is used preferablly.
838 -DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}}
834 +DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00{{/code}}
839 839  
840 840  In addition there are also additional parameters saved like:
841 841  
... ... @@ -847,9 +847,9 @@
847 847  ===== MHz ADCs =====
848 848  
849 849  similar to the GHz ADCs the MHz ADCs are saved with HDF5 names like:
850 -{{code language="none"}}/FL1/Experiment/BL1/SIS8300 100MHz ADC/CH2/TD{{/code}}
851 -DOOCS prop : FLASH.FEL/ADC.SIS.BL1/EXP1.CH02/CH00.TD
852 -DAQ channel: : FLASH.FEL/ADC.SIS.BL1/EXP1.CH02
846 +{{code language="none"}}/FL2/Experiment/MTCA-EXP1/SIS8300 100MHz ADC/CH2/TD{{/code}}
847 +DOOCS prop : FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH02/CH00.TD
848 +DAQ channel: : FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH02
853 853  
854 854  In addition there are also additional parameters saved like:
855 855  
... ... @@ -862,207 +862,54 @@
862 862  
863 863  \\
864 864  
865 -\\
861 +==== Pump Probe Laser (FLASH2) ====
866 866  
867 -\\
863 +There may be more information available from the "Laser DAQ". laese contact your Laser Local Contact.
868 868  
869 -\\
870 870  
866 +{{code language="none"}}/FL2/Experiment/Pump probe laser/FL24/attenuator position{{/code}}//always saved (PBD2)//
867 +DOOCS prop : {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS{{/code}}
868 +DAQ channel: {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS{{/code}}
869 +desc: attenuation of the PPLaser in the FL24 hutch (rotation of a waveplate)
870 +units : deg.
871 +
871 871  \\
872 872  
874 +
875 +{{code language="none"}}/FL2/Experiment/Pump probe laser/FL24/polarization position{{/code}}//always saved (PBD2)//
876 +DOOCS prop : {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/FPOS{{/code}}
877 +DAQ channel: {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/FPOS{{/code}}
878 +desc: attenuation of the PPLaser in the FL24 hutch (rotation of a waveplate)
879 +units : deg.
880 +
873 873  \\
874 874  
875 -(% class="wrapped" %)
876 -|=(((
877 -DAQ name
878 -)))|=(((
879 -HDF5 name
880 -)))
881 -|(((
882 -FLASH.UTIL/FL2.UND.MOTOR/FL2SASE3/GAP
883 -)))|(((
884 -/FL2/Electron Diagnostic/Undulator setting/SASE03 gap
885 -)))
886 -|(((
887 -FLASH.UTIL/FL2.UND.MOTOR/FL2SASE14/GAP
888 -)))|(((
889 -/FL2/Electron Diagnostic/Undulator setting/SASE14 gap
890 -)))
891 -|(((
892 -TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH
893 -)))|(((
894 -/FL2/Electron Diagnostic/Undulator setting/set wavelength
895 -)))
896 -|(((
897 -FLASH.FEL/XGM.PHOTONFLUX/FL2.HALL/PHOTONFLUX.UJ
898 -)))|(((
899 -/FL2/Photon Diagnostic/GMD/Average energy/hall
900 -)))
901 -|(((
902 -FLASH.FEL/XGM.PHOTONFLUX/FL2.HALL/PHOTONFLUX
903 -)))|(((
904 -/FL2/Photon Diagnostic/GMD/Average energy/hall (raw)
905 -)))
906 -|(((
907 -FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ
908 -)))|(((
909 -/FL2/Photon Diagnostic/GMD/Average energy/tunnel
910 -)))
911 -|(((
912 -FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX
913 -)))|(((
914 -/FL2/Photon Diagnostic/GMD/Average energy/tunnel (raw)
915 -)))
916 -|(((
917 -FLASH.FEL/XGM.POSMON/FL2.HALL/IX.POS
918 -)))|(((
919 -/FL2/Photon Diagnostic/GMD/Average beam position/position hall horizontal
920 -)))
921 -|(((
922 -FLASH.FEL/XGM.POSMON/FL2.HALL/IY.POS
923 -)))|(((
924 -/FL2/Photon Diagnostic/GMD/Average beam position/position hall vertical
925 -)))
926 -|(((
927 -FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS
928 -)))|(((
929 -/FL2/Photon Diagnostic/GMD/Average beam position/position tunnel horizontal
930 -)))
931 -|(((
932 -FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS
933 -)))|(((
934 -/FL2/Photon Diagnostic/GMD/Average beam position/position tunnel vertical
935 -)))
936 -|(((
937 -FLASH.FEL/XGM.BPM/FL2.HALL:0
938 -)))|(((
939 -/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position hall horizontal
940 -)))
941 -|(((
942 -FLASH.FEL/XGM.BPM/FL2.HALL:1
943 -)))|(((
944 -/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position hall vertical
945 -)))
946 -|(((
947 -FLASH.FEL/XGM.BPM/FL2.TUNNEL:0
948 -)))|(((
949 -/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel horizontal
950 -)))
951 -|(((
952 -FLASH.FEL/XGM.BPM/FL2.TUNNEL:1
953 -)))|(((
954 -/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel vertical
955 -)))
956 -|(((
957 -FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:1
958 -)))|(((
959 -/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy aux tunnel
960 -)))
961 -|(((
962 -FLASH.FEL/XGM.INTENSITY/FL2.HALL
963 -)))|(((
964 -/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy hall
965 -)))
966 -|(((
967 -FLASH.FEL/XGM.INTENSITY/FL2.HALL:0
968 -)))|(((
969 -/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy hall
970 -)))
971 -|(((
972 -FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL
973 -)))|(((
974 -/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel
975 -)))
976 -|(((
977 -FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:0
978 -)))|(((
979 -/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel
980 -)))
981 -|(((
982 -FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042
983 -)))|(((
984 -/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean phtoton energy
985 -)))
986 -|(((
987 -FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040
988 -)))|(((
989 -/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean wavelengt
990 -)))
991 -|(((
992 -FLASH.FEL/ADC.ADQ/OPIS1.CH02
993 -)))|(((
994 -/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Raw data/CH02
995 -)))
996 -|(((
997 -FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN/CHARGE.FLASH2
998 -)))|(((
999 -/FL2/Electron Diagnostic/Bunch charge/after undulator
1000 -)))
1001 -|(((
1002 -FLASH.DIAG/PBD2.TOROID.ML/3GUN/CHARGE.FLASH2
1003 -)))|(((
1004 -/FL2/Electron Diagnostic/Bunch charge/at gun
1005 -)))
1006 -|(((
1007 -FLASH.FEL/FL20T.PH.MOTOR/MOTOR1.MOT1/FPOS
1008 -)))|(((
1009 -/FL2/Beamlines/Tunnel Apertures/position aperture1 horizontal
1010 -)))
1011 -|(((
1012 -FLASH.FEL/FL20T.PH.MOTOR/MOTOR2.MOT1/FPOS
1013 -)))|(((
1014 -/FL2/Beamlines/Tunnel Apertures/position aperture1 vertical
1015 -)))
1016 -|(((
1017 -FLASH.FEL/ADC.SIS.FL2FS/FL20.SHUTTER
1018 -)))|(((
1019 -/FL2/Beamlines/FL20/Shutter/channel 0
1020 -)))
1021 -|(((
1022 -FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00
1023 -)))|(((
1024 -/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD
1025 -)))
1026 -|(((
1027 -FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH00
1028 -)))|(((
1029 -/FL2/Experiment/MTCA-EXP1/SIS8300 100MHz ADC/CH0/TD
1030 -)))
1031 -|(((
1032 -FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD
1033 -)))|(((
1034 -/FL2/Experiment/Pump probe laser/Synchronization/timing jitter RMS
1035 -)))
1036 -|(((
1037 -FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/LOCK_STATUS.VALUE.RD
1038 -)))|(((
1039 -/FL2/Experiment/Pump probe laser/Synchronization/timing jitter RMS GECCO
1040 -)))
1041 -|(((
1042 -FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD
1043 -)))|(((
1044 -/FL2/Experiment/Pump probe laser/laser delay readback
1045 -)))
1046 -|(((
1047 -FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION_SET.WR
1048 -)))|(((
1049 -/FL2/Experiment/Pump probe laser/laser delay set value
1050 -)))
1051 -|(((
1052 -FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS
1053 -)))|(((
1054 -/FL2/Experiment/Pump probe laser/FL24/attenuator position
1055 -)))
1056 -|(((
1057 -FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/POS
1058 -)))|(((
1059 -/FL2/Experiment/Pump probe laser/FL24/polarization position
1060 -)))
883 +{{code language="none"}}/FL1/Experiment/Pump probe laser/laser delay readback{{/code}}
884 +//always saved (PBD2)//
885 +DOOCS prop : {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD{{/code}}
886 +DAQ channel: {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD{{/code}}
887 +desc: delay of the Pump probe laser - measured by the read back position of the motor. There is also the set value available ( upto now these values are only updating every 1-2 seconds. There is no fast encoder property as on FLASH1 available)
888 +units : ps )
1061 1061  
1062 1062  \\
1063 1063  
892 +{{code language="none"}}/FL1/Experiment/Pump probe laser/Synchronization/timing jitter RMS{{/code}}
893 +//always saved (PBD)//
894 +DOOCS prop : {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD{{/code}}
895 +DAQ channel: {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD{{/code}}
896 +desc: rms jitter of the fs-Oscillator
897 +units: fs
898 +
1064 1064  [[Contents>>doc:||anchor="Contents"]]
1065 1065  
901 +\\
902 +
903 +=== "/uncategorized/" ===
904 +
905 + If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with their DOOCS names
906 +
907 +\\
908 +
1066 1066  === HDF5 structure revisions ===
1067 1067  
1068 1068  Starting with Beamblock 4, August 2018, the hierarchy of the HDF group names have been adapted to reflect the new situation at FLASH. FLASH2 is operating for users quite some time now. Therefore, both accelerators appear equally in their respective HDF groups, namely "/FL1" and "/FL2". The root group of proper, by run organised HDF files have an attribute called "version". This version attribute has changed from "0.2.x" to "0.3.x". The changes in detail: