Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,25 @@ 1 1 == Contents == 2 2 3 +\\ 3 3 5 +* [[General information about HDF5>>doc:||anchor="General information about HDF5"]] 6 +* [[FLASH HDF5 structure>>doc:||anchor="FLASH HDF5 structure"]] 7 +* [[Most popular FLASH parameters and their names in HDF5>>doc:||anchor="Most popular FLASH parameters and their names in HDF5"]] 8 +** [[FLASH1>>doc:||anchor="FLASH1"]] 9 +*** [[Beamline info (FLASH1)>>doc:||anchor="Beamline info (FLASH1)"]] 10 +*** [[Photon Diagnostics SASE / Spectrometer (FLASH1)>>doc:||anchor="Photon Diagnostics SASE / Spectrometer (FLASH1)"]] 11 +*** [[Electron Beam properties (FLASH1)>>doc:||anchor="Electron Beam properties (FLASH1)"]] 12 +*** [[Timing information, rep rate etc.(FLASH1)>>doc:||anchor="Timing information, rep rate etc.(FLASH1)"]] 13 +*** [[Pump Probe Laser (FLASH1)>>doc:||anchor="Pump Probe Laser (FLASH1)"]] 14 +*** [[User Data (FLASH1)>>doc:||anchor="User Data (FLASH1)"]] 15 +** [[FLASH2>>doc:||anchor="FLASH2"]] 16 +** [[HDF5 structure revisions>>doc:||anchor="HDF5 structure revisions"]] 17 +* [[Example code showing how to access HDF5 files>>doc:||anchor="Example code showing how to access HDF5 files"]] 18 +** [[Samples how to read HDF5 with Matlab>>doc:||anchor="Samples how to read HDF5 with Matlab"]] 19 +** [[How to read HDF5 with Python via FLASHH5>>doc:||anchor="How to read HDF5 with Python via FLASHH5"]] 20 +* [[HDF5 and DOOCS>>doc:||anchor="HDF5 and DOOCS"]] 4 4 5 - {{toc/}}22 +\\ 6 6 7 7 \\ 8 8 ... ... @@ -36,7 +36,7 @@ 36 36 37 37 \\ 38 38 39 -== Most popular FLASH parameters and their names in HDF5 ,DOOCS and (raw) DAQ==56 +== Most popular FLASH parameters and their names in HDF5 == 40 40 41 41 The complete list for the relation between DOOCS names and HDF5 names for the recordable parameters can be found in [[DESY's Repository~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://stash.desy.de/projects/CS/repos/pah/browse/src/camp/data/channel2HdfName.dat||shape="rect"]]. 42 42 The most common and often used ones are summarized below: ... ... @@ -79,7 +79,7 @@ 79 79 //always saved (PBD)// 80 80 DOOCS prop : {{code language="none"}}TTF2.FEL/BLFILTERS1/FILTER1/FW.MOTOR.POS{{/code}} 81 81 DAQ channel: {{code language="none"}}TTF2.FEL/BLFILTERS1/FILTER1/FW.MOTOR.POS{{/code}} 82 -desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASH USER.jddd-linked help pages.Filter-Units.Filtersin FLASH1and FLASH2.WebHome]]99 +desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]] 83 83 units: degree 84 84 \\ 85 85 ... ... @@ -87,7 +87,7 @@ 87 87 //always saved (PBD)// 88 88 DOOCS prop : {{code language="none"}}TTF2.FEL/BLFILTERS2/FILTER2/FW.MOTOR.POS{{/code}} 89 89 DAQ channel: {{code language="none"}}TTF2.FEL/BLFILTERS2/FILTER2/FW.MOTOR.POS{{/code}} 90 -desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASH USER.jddd-linked help pages.Filter-Units.Filtersin FLASH1and FLASH2.WebHome]]107 +desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]] 91 91 units: degree 92 92 \\ 93 93 ... ... @@ -123,7 +123,7 @@ 123 123 124 124 \\ 125 125 126 -==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]])/Spectrometer (FLASH1) ====143 +==== Photon Diagnostics SASE / Spectrometer (FLASH1) ==== 127 127 128 128 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 129 129 //always saved (PBD)// ... ... @@ -137,7 +137,7 @@ 137 137 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}} 138 138 DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}} 139 139 desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL 140 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**157 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 141 141 142 142 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel (raw){{/code}} 143 143 //always saved (PBD)// ... ... @@ -144,7 +144,7 @@ 144 144 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT14/VAL{{/code}} 145 145 DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.FF{{/code}} 146 146 desc :Energy per pulse Tunnel (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 147 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**164 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 148 148 149 149 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}} 150 150 //always saved (PBD)// ... ... @@ -158,7 +158,7 @@ 158 158 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}} 159 159 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}} 160 160 desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL 161 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**178 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 162 162 163 163 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA (raw){{/code}} 164 164 //always saved (PBD)// ... ... @@ -165,13 +165,13 @@ 165 165 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT15/VAL{{/code}} 166 166 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}} 167 167 desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 168 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**185 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 169 169 170 170 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}} 171 171 //always saved (PBD)// 172 172 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} 173 173 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} 174 -desc :Beam position of the photon Beam determined by the GMD (BDA, x=horizontal) 191 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, x=horizontal) 175 175 units : mm 176 176 177 177 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA vertical{{/code}} ... ... @@ -178,7 +178,7 @@ 178 178 //always saved (PBD)// 179 179 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}} 180 180 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}} 181 -desc :Beam position of the photon Beam determined by the GMD (BDA, y=vertical) 198 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, y=vertical) 182 182 units : mm 183 183 184 184 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel horizontal{{/code}} ... ... @@ -185,7 +185,7 @@ 185 185 //always saved (PBD)// 186 186 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}} 187 187 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}} 188 -desc :Beam position of the photon Beam determined by the GMD (TUNNEL, x=horizontal) 205 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, x=horizontal) 189 189 units : mm 190 190 191 191 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel vertical{{/code}} ... ... @@ -192,7 +192,7 @@ 192 192 //always saved (PBD)// 193 193 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}} 194 194 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}} 195 -desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical) 212 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, y=vertical) 196 196 units : mm 197 197 198 198 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}} ... ... @@ -280,7 +280,7 @@ 280 280 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}} 281 281 desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data) 282 282 units: ps (bigger numbers indicate later arrivaltime of the electrons) 283 -note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach :BAM-basics300 +note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>url:https://confluence.desy.de/download/attachments/134216957/BAM-basics_and_outlook-2018_DESY-template_16-9Format.pdf?version=1&modificationDate=1565162143328&api=v2||shape="rect"]] 284 284 285 285 ===== electron beam profile ===== 286 286 ... ... @@ -385,7 +385,7 @@ 385 385 //always saved (PBD)// 386 386 DOOCS prop : {{code language="none"}}none{{/code}} 387 387 DAQ channel: {{code language="none"}}none{{/code}} 388 -desc: Each 10 Hz burst has its unique train ID. For the HDF5 data 405 +desc: Each 10 Hz burst has its unique train ID. For the HDF5 dataset the ID is the same for all parameters with the same index (note camera images may be shifted by 1 ID - talk to the experts !) 389 389 units: 390 390 \\ 391 391 ... ... @@ -392,7 +392,7 @@ 392 392 ===== Train time ===== 393 393 394 394 {{code language="none"}}/Timing/train time{{/code}} 395 -desc:Local time as array of day, hour, minute, second, and centisecond. This data zation purposes only. For correlations use the train ID or the Unix time of the time stamp412 +desc:Local time as array of day, hour, minute, second, and centisecond. This dataset is meant for visualisation purposes only. For correlations use the train ID or the Unix time of the time stamp 396 396 units: d h min s cs 397 397 \\ 398 398 ... ... @@ -458,15 +458,9 @@ 458 458 459 459 ==== User Data (FLASH1) ==== 460 460 461 -The data saved specifically for detectors at an experiment will show up in /Experiment/ there is a large number of options for cameras or monitoring pslow properties (motor positons etc) for user experiments. For details please ask your local contact. 462 - 463 -NOTE: If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with the DOOCS names 464 - 465 -The most common and permanently installed device used by experiment are our ADCs: 466 - 467 467 ===== GHz ADCs ===== 468 468 469 -ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found **[[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]]**480 +ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found [[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]] 470 470 //saved on DEMAND in the user DAQ// 471 471 \\The HDF5 names for the ADC traces are depending on the beamline : 472 472 \\PG Beamline: ... ... @@ -489,12 +489,14 @@ 489 489 here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} conatins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is used preferablly. 490 490 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}} 491 491 492 - In addition there are also additional parameters saved like:503 +in addition there are also additional parameters saved like: 493 493 494 -* {{code language="none"}}sample frequency{{/code}}:it shows the sample frequencyinMHz(number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains.495 -* {{codelanguage="none"}}numberofsamples{{/code}}:total number of samoles recorded for each 10 Hztrigger496 -* {{code language="none"}}error (ADC):{{/code}} 0 indicatesthat there was no error505 +* sample frequency (in MHz) 506 +* error (state) 507 +* offset 497 497 509 +~| 510 + 498 498 ===== MHz ADCs ===== 499 499 500 500 similar to the GHz ADCs the MHz ADCs are saved with HDF5 names like: ... ... @@ -502,19 +502,10 @@ 502 502 DOOCS prop : FLASH.FEL/ADC.SIS.BL1/EXP1.CH02/CH00.TD 503 503 DAQ channel: : FLASH.FEL/ADC.SIS.BL1/EXP1.CH02 504 504 505 - In addition there are also additional parameters saved like:518 +\\ 506 506 507 -* {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains. 508 -* {{code language="none"}}number of samples{{/code}}: total number of samoles recorded for each 10 Hz trigger 509 - 510 510 [[Contents>>doc:||anchor="Contents"]] 511 511 512 -\\ 513 - 514 -\\ 515 - 516 -\\ 517 - 518 518 === FLASH2 === 519 519 520 520 There is analog to FLASH1 a permanently running "PhotonDagnostic DAQ FLASH2" (PBD2) and 2 User DAQs ... ... @@ -522,11 +522,11 @@ 522 522 ==== Beamline info (FLASH2) ==== 523 523 524 524 (% style="color: rgb(255,153,0);" %)(not yet available){{code language="none"}}/FL2/Beamlines/Attenuator/pressure {{/code}}(%%) 525 - (% style="color: rgb(193,199,208);" %)//always saved (PBD2)//(%%)526 - (% style="color: rgb(193,199,208);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}}(%%)527 - (% style="color: rgb(193,199,208);" %)DAQ channel: {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}}(%%)528 - (% style="color: rgb(193,199,208);" %)desc: set pressure in the gas attenuator(%%)529 - (% style="color: rgb(193,199,208);" %)units: mbar(%%)529 +//always saved (PBD2)// 530 +DOOCS prop : {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} 531 +DAQ channel: {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} 532 +desc: set pressure in the gas attenuator 533 +units: mbar 530 530 \\ 531 531 532 532 {{code language="none"}}/FL2/Beamlines/FL20/Shutter/open{{/code}} ... ... @@ -541,13 +541,13 @@ 541 541 //always saved (PBD2)// 542 542 DOOCS prop : {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS{{/code}} 543 543 DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS 544 -desc: Position of the BL filter wheel 1 - to correlate with the filter material please look **[[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filtersin FLASH1and FLASH2.WebHome]]**548 +desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]] 545 545 units: degree 546 546 \\ 547 547 548 548 549 549 //always saved (PBD2)// 550 -\\\\ **[[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filtersin FLASH1and FLASH2.WebHome]]**554 +\\\\[[here>>doc:FLASH.Filter history (BL filterwheel 12)]] 551 551 {{code language="none"}}/FL2/Beamlines/Filter wheel/position wheel 2 DOOCS prop : FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS desc: Position of the BL filter wheel 2 - to correlate with the filter material please look units: degree{{/code}} 552 552 553 553 \\ ... ... @@ -560,13 +560,15 @@ 560 560 561 561 \\ 562 562 563 - ==== Photon Diagnostics SASE ([[XGMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]] - FLASH2) ====567 +\\ 564 564 569 +==== Photon Diagnostics SASE (XGMD) ==== 570 + 565 565 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 566 566 //always saved (PBD2)// 567 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}}568 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}}569 -desc : calibrated average ( ~~ 20 sec averaging time )SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)573 +DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ 574 +DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ 575 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current) 570 570 units : microJ 571 571 572 572 \\ ... ... @@ -573,12 +573,12 @@ 573 573 574 574 (% style="color: rgb(255,204,0);" %)average Sigma to be included in 575 575 576 - (% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}}(%%)577 - (% style="color: rgb(193,199,208);" %)//always saved (PBD2)//(%%)578 - (% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA(%%)579 - (% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA(%%)580 - (% style="color: rgb(193,199,208);" %)desc :This parameter gives an indicationof the error of the measurement of the average pulse energy. This takes signal to noise, detector resolution, uncertainties in crossectionetc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)581 - (% style="color: rgb(193,199,208);" %)units : microJ582 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} 583 +//always saved (PBD2)// 584 +DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA 585 +DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA 586 +desc : (ion current) 587 +units : microJ 582 582 583 583 \\ 584 584 ... ... @@ -585,327 +585,269 @@ 585 585 \\ 586 586 587 587 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 588 -//always saved (PBD 2)//589 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}590 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}591 -desc : measured in theTunnelinfromtofthegas attenuatorandtheapertures in theHall)592 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**594 +//always saved (PBD)// 595 +DOOCS prop : FLASH.FEL/XGM.INTENSITY/FL2.HALL/INTENSITY.TD 596 +DAQ channel: FLASH.FEL/XGM.INTENSITY/FL2.HALL/INTENSITY.TD 597 +desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL 598 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 593 593 594 594 \\ 595 595 596 596 \\ 597 597 598 -{{code language="none"}}/FL 2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunneluncertainty (sigma){{/code}}599 -//always saved (PBD 2)//600 -DOOCS prop : LASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}}601 -DAQ channel: {{code language="none"}} FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}}602 -desc : (% style="color: rgb(0,0,0);"%)Thisparametergivesanindication of theerrorof themeasurementof thepulseenergy. Thistakessignalto noise, detectorresolution, uncertaintiesin crossectionetcintoaccount. (it is NOT themeasurementofthestatisticalfluctuation of the SASE pulses)(%%)603 -units : a.u. (more or less µJ -related tothe value of the pulse energy)604 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel (raw){{/code}} 605 +//always saved (PBD)// 606 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT14/VAL{{/code}} 607 +DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.FF{{/code}} 608 +desc :Energy per pulse Tunnel (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 609 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 604 604 611 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}} 612 +//always saved (PBD)// 613 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}} 614 +DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}} 615 +desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current) 616 +units : microJ 605 605 606 -{{code language="none"}}{{/code}} 618 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}} 619 +//always saved (PBD)// 620 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}} 621 +DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}} 622 +desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL 623 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 607 607 608 -All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall ! 625 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA (raw){{/code}} 626 +//always saved (PBD)// 627 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT15/VAL{{/code}} 628 +DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}} 629 +desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 630 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 609 609 610 -\\ 632 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}} 633 +//always saved (PBD)// 634 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} 635 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} 636 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, x=horizontal) 637 +units : mm 611 611 612 -Besides pulse energy the GMD also provides information about the beam position 639 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA vertical{{/code}} 640 +//always saved (PBD)// 641 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}} 642 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}} 643 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (BDA, y=vertical) 644 +units : mm 613 613 614 -\\ 615 - 616 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel horizontal{{/code}} 617 -//always saved (PBD2)// 618 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}} 619 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}} 620 -desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the GMD (tunnel, x=horizontal) 646 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel horizontal{{/code}} 647 +//always saved (PBD)// 648 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}} 649 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}} 650 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, x=horizontal) 621 621 units : mm 622 622 623 -\\ 624 - 625 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel vertical{{/code}} 626 -//always saved (PBD2)// 627 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}} 628 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}} 629 -desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the GMD (tunnel, x=horizontal) 653 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel vertical{{/code}} 654 +//always saved (PBD)// 655 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}} 656 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}} 657 +desc :Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (TUNNEL, y=vertical) 630 630 units : mm 631 631 632 632 \\ 633 633 634 - 635 -//always saved (PBD2)// 636 -\\\\{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel x DOOCS prop : FLASH.FEL/XGM.BPM/FL2.HALL/X.TDDAQ channel: FLASH.FEL/XGM.BPM/FL2.HALL:2 desc: {{/code}}Besides the well calibrated averaged beam position information there is also the option 637 -{{code language="none"}}to measure the beam position on a single bunch level. HOWEVER this methide needs a perfectly adjusted signal level (talk to your local contact !!) and also then the signal to noise is rather small and one needs some averaging ... BUT with this option one can determine if there was a spatial slope on a burst (say forst bunches were lower than the last ones or so ...)units : mm {{/code}} 638 - 639 -{{code language="none"}}(x=horizontal, y = vertial){{/code}} 640 - 641 -again the same parameter set is available for the **HALL GMD** 642 - 643 643 \\ 644 644 645 645 \\ 646 646 647 -==== Photon Diagnostics OPIS[[ >>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]](FLASH2) ==== 666 +(% class="wrapped" %) 667 +|=((( 668 +DAQ name 669 +)))|=((( 670 +HDF5 name 671 +))) 672 +|((( 673 +FLASH.UTIL/FL2.UND.MOTOR/FL2SASE3/GAP 674 +)))|((( 675 +/FL2/Electron Diagnostic/Undulator setting/SASE03 gap 676 +))) 677 +|((( 678 +FLASH.UTIL/FL2.UND.MOTOR/FL2SASE14/GAP 679 +)))|((( 680 +/FL2/Electron Diagnostic/Undulator setting/SASE14 gap 681 +))) 682 +|((( 683 +TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH 684 +)))|((( 685 +/FL2/Electron Diagnostic/Undulator setting/set wavelength 686 +))) 687 +|((( 688 +FLASH.FEL/XGM.PHOTONFLUX/FL2.HALL/PHOTONFLUX.UJ 689 +)))|((( 690 +/FL2/Photon Diagnostic/GMD/Average energy/hall 691 +))) 692 +|((( 693 +FLASH.FEL/XGM.PHOTONFLUX/FL2.HALL/PHOTONFLUX 694 +)))|((( 695 +/FL2/Photon Diagnostic/GMD/Average energy/hall (raw) 696 +))) 697 +|((( 698 +FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ 699 +)))|((( 700 +/FL2/Photon Diagnostic/GMD/Average energy/tunnel 701 +))) 702 +|((( 703 +FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX 704 +)))|((( 705 +/FL2/Photon Diagnostic/GMD/Average energy/tunnel (raw) 706 +))) 707 +|((( 708 +FLASH.FEL/XGM.POSMON/FL2.HALL/IX.POS 709 +)))|((( 710 +/FL2/Photon Diagnostic/GMD/Average beam position/position hall horizontal 711 +))) 712 +|((( 713 +FLASH.FEL/XGM.POSMON/FL2.HALL/IY.POS 714 +)))|((( 715 +/FL2/Photon Diagnostic/GMD/Average beam position/position hall vertical 716 +))) 717 +|((( 718 +FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS 719 +)))|((( 720 +/FL2/Photon Diagnostic/GMD/Average beam position/position tunnel horizontal 721 +))) 722 +|((( 723 +FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS 724 +)))|((( 725 +/FL2/Photon Diagnostic/GMD/Average beam position/position tunnel vertical 726 +))) 727 +|((( 728 +FLASH.FEL/XGM.BPM/FL2.HALL:0 729 +)))|((( 730 +/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position hall horizontal 731 +))) 732 +|((( 733 +FLASH.FEL/XGM.BPM/FL2.HALL:1 734 +)))|((( 735 +/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position hall vertical 736 +))) 737 +|((( 738 +FLASH.FEL/XGM.BPM/FL2.TUNNEL:0 739 +)))|((( 740 +/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel horizontal 741 +))) 742 +|((( 743 +FLASH.FEL/XGM.BPM/FL2.TUNNEL:1 744 +)))|((( 745 +/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel vertical 746 +))) 747 +|((( 748 +FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:1 749 +)))|((( 750 +/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy aux tunnel 751 +))) 752 +|((( 753 +FLASH.FEL/XGM.INTENSITY/FL2.HALL 754 +)))|((( 755 +/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy hall 756 +))) 757 +|((( 758 +FLASH.FEL/XGM.INTENSITY/FL2.HALL:0 759 +)))|((( 760 +/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy hall 761 +))) 762 +|((( 763 +FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL 764 +)))|((( 765 +/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel 766 +))) 767 +|((( 768 +FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:0 769 +)))|((( 770 +/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel 771 +))) 772 +|((( 773 +FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042 774 +)))|((( 775 +/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean phtoton energy 776 +))) 777 +|((( 778 +FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040 779 +)))|((( 780 +/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean wavelengt 781 +))) 782 +|((( 783 +FLASH.FEL/ADC.ADQ/OPIS1.CH02 784 +)))|((( 785 +/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Raw data/CH02 786 +))) 787 +|((( 788 +FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN/CHARGE.FLASH2 789 +)))|((( 790 +/FL2/Electron Diagnostic/Bunch charge/after undulator 791 +))) 792 +|((( 793 +FLASH.DIAG/PBD2.TOROID.ML/3GUN/CHARGE.FLASH2 794 +)))|((( 795 +/FL2/Electron Diagnostic/Bunch charge/at gun 796 +))) 797 +|((( 798 +FLASH.FEL/FL20T.PH.MOTOR/MOTOR1.MOT1/FPOS 799 +)))|((( 800 +/FL2/Beamlines/Tunnel Apertures/position aperture1 horizontal 801 +))) 802 +|((( 803 +FLASH.FEL/FL20T.PH.MOTOR/MOTOR2.MOT1/FPOS 804 +)))|((( 805 +/FL2/Beamlines/Tunnel Apertures/position aperture1 vertical 806 +))) 807 +|((( 808 +FLASH.FEL/ADC.SIS.FL2FS/FL20.SHUTTER 809 +)))|((( 810 +/FL2/Beamlines/FL20/Shutter/channel 0 811 +))) 812 +|((( 813 +FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00 814 +)))|((( 815 +/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD 816 +))) 817 +|((( 818 +FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH00 819 +)))|((( 820 +/FL2/Experiment/MTCA-EXP1/SIS8300 100MHz ADC/CH0/TD 821 +))) 822 +|((( 823 +FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD 824 +)))|((( 825 +/FL2/Experiment/Pump probe laser/Synchronization/timing jitter RMS 826 +))) 827 +|((( 828 +FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/LOCK_STATUS.VALUE.RD 829 +)))|((( 830 +/FL2/Experiment/Pump probe laser/Synchronization/timing jitter RMS GECCO 831 +))) 832 +|((( 833 +FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD 834 +)))|((( 835 +/FL2/Experiment/Pump probe laser/laser delay readback 836 +))) 837 +|((( 838 +FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION_SET.WR 839 +)))|((( 840 +/FL2/Experiment/Pump probe laser/laser delay set value 841 +))) 842 +|((( 843 +FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS 844 +)))|((( 845 +/FL2/Experiment/Pump probe laser/FL24/attenuator position 846 +))) 847 +|((( 848 +FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/POS 849 +)))|((( 850 +/FL2/Experiment/Pump probe laser/FL24/polarization position 851 +))) 648 648 649 -for more info see:** [[ OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]** 650 - 651 -(The OPIS hall is not installed yet ...) 652 - 653 653 \\ 654 654 655 -{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean photon energy{{/code}} 656 -// saved opon request (PBD2)// 657 -DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}} 658 -DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}} 659 -desc : mean photon energy ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy) 660 -units : eV 661 - 662 -\\ 663 - 664 -{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean wavelength{{/code}} 665 -// saved opon request (PBD2)// 666 -DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}} 667 -DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}} 668 -desc : meanwavelength ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy) 669 -units : nm 670 - 671 -\\ 672 - 673 -{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/number of analyzed bunch (in older version this can be found in OPIS tunnel/Expert stuff/General operation parameters/){{/code}} 674 -// saved opon request (PBD2)// 675 -DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}} 676 -DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}} 677 -desc : The bunch number of the bunch used for the wavelength calculation 678 -units : 679 - 680 -\\ 681 - 682 -If Opis is running typically on the the averaged data is saved. For several experiments it may make sense to save the information for each single bunch. This is up to now done by savng the compleate ADC trace of the TOF setup. This is a huge amount of data and needs processing. This has to be performed after the beamtime in close contact to [[Markus Braune>>mailto:markus.braune@desy.de||shape="rect"]] ( respobsible for [[OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]) 683 - 684 -\\ 685 - 686 -In case OPIS was not operating there is still informaton about the **set wavelength** for the undulators (see below) which may differ by up to 5 % from the actual wavelength due to different settings in the FEL ... 687 - 688 -\\ 689 - 690 -\\ 691 - 692 -==== Electron Beam properties (FLASH2) ==== 693 - 694 -===== bunch charge ===== 695 - 696 -{{code language="none"}}/FL2/Electron Diagnostic/Bunch charge/after undulator{{/code}} 697 -//always saved (PBD2)// 698 -DOOCS prop : {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN/CHARGE.FLASH2{{/code}} 699 -DAQ channel: {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN/CHARGE.FLASH2{{/code}} 700 -desc: electron bunch charge FLASH2 (average value for each bunchtrain). 701 -units: nC 702 - 703 -\\ 704 - 705 -===== undulator settings ===== 706 - 707 -{{code language="none"}}/FL2/Electron Diagnostic/Undulator setting/set wavelength{{/code}} 708 -//always saved (PBD2)// 709 -DOOCS prop : {{code language="none"}}TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH{{/code}} 710 -DAQ channel: {{code language="none"}}TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH{{/code}} 711 -desc: Set value for the anticipated wavelength . This parameter is used to set the undulator gap. It may however deviate from the actual wavelength by several % ... 712 -units: nm 713 - 714 -{{code language="none"}}/FL2/Electron Diagnostic/Undulator setting/SASE14 gap{{/code}} 715 -//always saved (PBD2)// 716 -DOOCS prop : {{code language="none"}}FLASH.UTIL/FL2.UND.MOTOR/FL2SASE14/GAP{{/code}} 717 -DAQ channel: {{code language="none"}}FLASH.UTIL/FL2.UND.MOTOR/FL2SASE14/GAP{{/code}} 718 -desc: gap value of the undulators. This can be used to follow up how many undulators were closed and if there was a taper 719 -units: mm 720 - 721 -The gap values are saved for all 12 undulators (Nr 3 to 14). Undulator 14 is the one closest to the experimental hall. 722 - 723 -===== 724 -arrival time ===== 725 - 726 -**FL1**{{code language="none"}}//Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}} 727 -//always saved (PBD2)// 728 -DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}} 729 -DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}} 730 -desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data) 731 -units: ps (bigger numbers indicate later arrivaltime of the electrons) 732 - 733 -The BAM measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !). The first values are for FLASH1 bunches. 734 -After a gap of about 70 micros ( 70 colums) with as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start. The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... 735 - 736 -Docu for BAM: [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]] 737 - 738 - 739 739 [[Contents>>doc:||anchor="Contents"]] 740 740 741 -\\ 742 - 743 -==== Timing information, rep rate etc. (FLASH2) ==== 744 - 745 -===== start time of FLASH2 ===== 746 - 747 -{{code language="none"}}/FL2/Timing/start time flash2{{/code}} 748 -//always saved (PBD2)// 749 -DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/BUNCH_POSITION.2{{/code}} 750 -DAQ channel: {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/BUNCH_POSITION.2{{/code}} 751 -desc: The max 600 µs acceleration time of FLASH is devided between FLASH1 and FLASH2. This 600 µs window starts with FLASH1 (up to now) at a time"label" of 700 µs (for historic reasons). Thus the first bunch of FLASH 1 comes at "700" and the last possibel bunch comes at 1300 (700+600). After FLASH1 train is over ther is a about 70µs switching time with no bunches. Then comes the first FLASH2 bunch. Thus if e.g. the start time of FLASH2 is 1200 it means that FLASH2 starts at column 500 (1200-700) in the HDF5 files. (However for yet unknown reasons this may change by 2-3 colums ...) 752 -units: µs 753 - 754 -===== bunch repetition rate ===== 755 - 756 -{{code language="none"}}/FL2/Timing/repetition rate{{/code}} 757 -//always saved (PBD2)// 758 -DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/REP_RATE_KHZ.2{{/code}} 759 -DAQ channel: {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/REP_RATE_KHZ.2{{/code}} 760 -desc: repetition rate of the bunches / pulses within the burst (FLASH2) 761 -units: kHz 762 - 763 -===== actual number of pulses ===== 764 - 765 -{{code language="none"}}/FL1/Timing/actual number of bunches{{/code}} 766 -//always saved (PBD2)// 767 -DOOCS prop : {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/3GUN/NUMBEROFBUNCHES.FLASH2{{/code}} 768 -DAQ channel: {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/3GUN/NUMBEROFBUNCHES.FLASH2{{/code}} 769 -desc: Number of bunches measured BEHIND the undulator. If pulses are used for diagnostic of the protection system of the accelerator limits the number of bunches to be accelerated this is the actual number that created XUV radiation.The number is calculated by the DAQ middle layer server, (FLASH2) 770 -units: 771 -\\ 772 - 773 -===== actual pulse pattern recorded after the undulator ===== 774 - 775 -{{code language="none"}}/FL1/Timing/Bunch pattern/pattern after undulator{{/code}} 776 -//always saved (PBD2)// 777 -DOOCS prop : {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN.PULSEPATTERN{{/code}} 778 -DAQ channel: {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN.PULSEPATTERN{{/code}} 779 -desc: The bunch pattern as function of time in a burst recorded by toroide diagnostic BEHIND the undulator. (FLASH2) 780 -units: 781 -\\ 782 - 783 -===== Train ID ===== 784 - 785 -{{code language="none"}}/Timing/train ID{{/code}} 786 -//always saved (PBD2)// 787 -DOOCS prop : {{code language="none"}}none{{/code}} 788 -DAQ channel: {{code language="none"}}none{{/code}} 789 -desc: Each 10 Hz burst has its unique train ID. For the HDF5 dataset the ID is the same for all parameters with the same index (note camera images may be shifted by 1 ID - talk to the experts !) 790 -units: 791 -\\ 792 - 793 -===== Train time ===== 794 - 795 -//always saved (PBD2) 796 -//{{code language="none"}}/Timing/train time{{/code}} 797 -desc:Local time as array of day, hour, minute, second, and centisecond. This dataset is meant for visualisation purposes only. For correlations use the train ID or the Unix time of the time stamp 798 -units: d h min s cs 799 -\\ 800 - 801 -{{code language="none"}}/Timing/time stamp{{/code}} 802 - 803 -//always saved (PBD2)// 804 -desc: first column: Local time in unix time. To get day, hour, minute, second you can use unix: e.g. date ~-~-date='@1553617729' or matlab, python etc 805 -second column: microseconds 806 -third column: Train ID of FLASH 807 -\\ 808 - 809 -[[Contents>>doc:||anchor="Contents"]] 810 - 811 -\\ 812 - 813 -==== User Data (FLASH2) ==== 814 - 815 -The data saved specifically for detectors at an experiment will show up in /Experiment/ there is a large number of options for cameras or monitoring pslow properties (motor positons etc) for user experiments. For details please ask your local contact. 816 - 817 -NOTE: If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with the DOOCS names 818 - 819 -The most common and permanently installed device used by experiment are our ADCs: 820 - 821 -===== GHz ADCs ===== 822 - 823 -ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found** [[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]]** 824 -//saved on DEMAND in the user DAQ// 825 -\\Up to now there are 4 channels available at FL24 826 -\\\\{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD{{/code}} 827 -{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH01/TD{{/code}} 828 -\\{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH02/TD{{/code}}{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH03/TD{{/code}} 829 - 830 -\\ 831 - 832 -DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00/CH00.TD or CH00.DAQ.TD{{/code}} 833 -here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} conatins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is used preferablly. 834 -DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00{{/code}} 835 - 836 -In addition there are also additional parameters saved like: 837 - 838 -* {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains. 839 -* {{code language="none"}}number of samples{{/code}}: total number of samoles recorded for each 10 Hz trigger 840 -* {{code language="none"}}error (ADC):{{/code}} 0 indicates that there was no error 841 -* {{code language="none"}}/CH0-CH3/offset{{/code}}: To use the full dynamic range of the ADC one can shift the base line . This offset is saved here. 842 - 843 -===== MHz ADCs ===== 844 - 845 -similar to the GHz ADCs the MHz ADCs are saved with HDF5 names like: 846 -{{code language="none"}}/FL2/Experiment/MTCA-EXP1/SIS8300 100MHz ADC/CH2/TD{{/code}} 847 -DOOCS prop : FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH02/CH00.TD 848 -DAQ channel: : FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH02 849 - 850 -In addition there are also additional parameters saved like: 851 - 852 -* {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains. 853 -* {{code language="none"}}number of samples{{/code}}: total number of samoles recorded for each 10 Hz trigger 854 - 855 -[[Contents>>doc:||anchor="Contents"]] 856 - 857 -\\ 858 - 859 -\\ 860 - 861 -==== Pump Probe Laser (FLASH2) ==== 862 - 863 -There may be more information available from the "Laser DAQ". laese contact your Laser Local Contact. 864 - 865 - 866 -{{code language="none"}}/FL2/Experiment/Pump probe laser/FL24/attenuator position{{/code}}//always saved (PBD2)// 867 -DOOCS prop : {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS{{/code}} 868 -DAQ channel: {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS{{/code}} 869 -desc: attenuation of the PPLaser in the FL24 hutch (rotation of a waveplate) 870 -units : deg. 871 - 872 -\\ 873 - 874 - 875 -{{code language="none"}}/FL2/Experiment/Pump probe laser/FL24/polarization position{{/code}}//always saved (PBD2)// 876 -DOOCS prop : {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/FPOS{{/code}} 877 -DAQ channel: {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/FPOS{{/code}} 878 -desc: attenuation of the PPLaser in the FL24 hutch (rotation of a waveplate) 879 -units : deg. 880 - 881 -\\ 882 - 883 -{{code language="none"}}/FL1/Experiment/Pump probe laser/laser delay readback{{/code}} 884 -//always saved (PBD2)// 885 -DOOCS prop : {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD{{/code}} 886 -DAQ channel: {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD{{/code}} 887 -desc: delay of the Pump probe laser - measured by the read back position of the motor. There is also the set value available ( upto now these values are only updating every 1-2 seconds. There is no fast encoder property as on FLASH1 available) 888 -units : ps ) 889 - 890 -\\ 891 - 892 -{{code language="none"}}/FL1/Experiment/Pump probe laser/Synchronization/timing jitter RMS{{/code}} 893 -//always saved (PBD)// 894 -DOOCS prop : {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD{{/code}} 895 -DAQ channel: {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD{{/code}} 896 -desc: rms jitter of the fs-Oscillator 897 -units: fs 898 - 899 -[[Contents>>doc:||anchor="Contents"]] 900 - 901 -\\ 902 - 903 -=== "/uncategorized/" === 904 - 905 - If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with their DOOCS names 906 - 907 -\\ 908 - 909 909 === HDF5 structure revisions === 910 910 911 911 Starting with Beamblock 4, August 2018, the hierarchy of the HDF group names have been adapted to reflect the new situation at FLASH. FLASH2 is operating for users quite some time now. Therefore, both accelerators appear equally in their respective HDF groups, namely "/FL1" and "/FL2". The root group of proper, by run organised HDF files have an attribute called "version". This version attribute has changed from "0.2.x" to "0.3.x". The changes in detail: