Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 28.1
edited by sndueste
on 2019/10/22 08:53
Change comment: There is no comment for this version
To version 40.1
edited by sndueste
on 2021/02/09 14:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,9 +8,9 @@
8 8  
9 9  == General information about HDF5 ==
10 10  
11 -HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://www.hdfgroup.org/HDF5/||shape="rect"]]
11 +HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://portal.hdfgroup.org/display/support||shape="rect"]]
12 12  
13 -To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://support.hdfgroup.org/products/java/hdfview/index.html||shape="rect"]]
13 +To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://portal.hdfgroup.org/display/support/Download+HDFView||shape="rect"]]
14 14  
15 15  For use on the DESY Maxwell or PAL (max-fsc or pal) **hdfview** is available in the xray module :
16 16  {{code language="none"}}> module load xray{{/code}}
... ... @@ -18,51 +18,93 @@
18 18  
19 19  [[Contents>>doc:||anchor="Contents"]]
20 20  
21 -== FLASH HDF5 structure ==
21 +== The new (starting 2021) HDF5 format ==
22 22  
23 -The photon diagnostic, electron diagnostic and beamline information as well as the information about the pump-probe laser and the infrastructure offered for users (GHz/MHz ADCs) can be included in one HDF5 file which is organised according to train IDs. The general structure is:
23 +\\
24 24  
25 +FLASH provides a conversion of its data acquisition (DAQ) to the commonly used [[HDF5>>url:https://www.hdfgroup.org/solutions/hdf5/||shape="rect"]] format. Correlated  data are mapped by a primary index called **train ID**. Every data set has an individual index of train IDs to identify the data even when data are missing or deviate in update rate.If the data set of choice contains gaps,  users have to decide how to treat missing values. DAQ channels are spread across various files with one file name pattern for each DAQ. This means users have to assemble data from different files if necessary.
26 +
27 +The hierarchy is realized using a human readable named HDF tree with each DAQ channel containing the data sets "//value//" and "//index//". Additionally, the HDF group //zraw// contains a tree of the original DAQ channel names.
28 +
29 +Reference implementation, which follows the concept of Python libraries like Pandas, Xarray, or Dask, is given below.
30 +
31 +\\
32 +
33 +{{expand title="Discontinued HDF formats"}}
34 +== Comparison to FLASH's deprecated HDF formats ==
35 +
36 +Before 2021, FLASH provided two different HDF formats formally known as //near-online// and //offline// HDF files.
37 +
38 +All data sets were aligned by the same global index by filling in missing data. Fast DAQ channels  (pulse synchronous data - update 10 Hz) are filled in by NaN or 0, slow channels (not pulse synchronous data - update e.g. 1 Hz ) are interpolated by the DAQs libraries, by keeping the value constant up to the next change.
39 +
40 +While the near-online HDF files were converted live during the beamtime, the offline HDF files were manually compiled weeks/months later. Near-online HDF files were used by a provided API [[BeamtimeDaqAccess>>url:https://confluence.desy.de/display/FLASHUSER/Near-Online+data+analysis#Near-Onlinedataanalysis-BriefUserGuidetoBeamtimeDAQAccess||shape="rect"]], which also searches for DAQ channels in files. With assembled files "by run", all DAQ channels were existing in the same HDF file. While shorter runs usually fitted into one file, longer runs still had to be aggregated over several files. The creation of the assembled type of files still involves the use of fairly unstable DAQ Mex-functions As the environment required for using the Mex-functions is already deprecated, its continued existence is uncertain.
41 +
42 +The HDF hierarchy is almost identical in all formats. While in the the recent format each DAQ channel contains the data sets "value" and "index", the deprecated format had one data set for each DAQ channel. The deprecated formats supplies no time axis parameters for spectra data types.
43 +{{/expand}}
44 +
45 +== HDF excerpt: ==
46 +
47 +\\
48 +
49 +ADC data as example for **fast** **data** (10 Hz):
50 +
51 +\\
52 +
53 +[[image:attach:image2020-11-16_15-26-28.png||height="250"]]
54 +
55 +\\
56 +
57 +{{info title="Sample scripts in python"}}
58 +== Reference implementation (Python) ==
59 +
60 +[[~[~[image:attach:binder_badge.png~|~|thumbnail="true" width="120"~]~]>>url:https://mybinder.org/v2/git/https%3A%2F%2Fgitlab.desy.de%2Fchristopher.passow%2Fflash-daq-hdf/master||shape="rect"]]
61 +
62 +(% class="Object" %)[[https:~~/~~/gitlab.desy.de/christopher.passow/flash-daq-hdf>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]]
63 +{{/info}}
64 +
65 +\\
66 +
67 +\\
68 +
69 +== The discontinued (till 2021) FLASH HDF5 structure ==
70 +
71 +The photon diagnostic, electron diagnostic and beamline information as well as the information about the pump-probe laser and the infrastructure offered for users (GHz/MHz ADCs) can be included in one HDF5 file which is organized according to train IDs. The general structure is:
72 +
25 25  * Electron Diagnostic
26 26  * Photon Diagnostics
27 27  * Beamlines
28 28  * Experiment
29 29  * Timing
30 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/HDF5main/HDF5_structure.jpg~|~|alt="HDF5_structure.jpg" width="700" height="500"~]~]>>attach:HDF5_structure.jpg]]
78 +[[image:attach:HDF5_structure.jpg||height="400"]]
31 31  
32 -A detailled description of (most) channels can be found in the lower part of the hdf5 viewer:
33 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/HDF5main/HDF5_structure_desc.jpg~|~|alt="HDF5_structure_desc.jpg" width="341" height="413"~]~]>>attach:HDF5_structure_desc.jpg]]
80 +A detailed description of (most) channels can be found in the lower part of the hdf5 viewer:
81 +[[image:attach:HDF5_structure_desc.jpg||thumbnail="true" height="250"]]
34 34  
35 35  [[Contents>>doc:||anchor="Contents"]]
36 36  
37 37  \\
38 38  
39 -== HDF5 example files ==
87 +=== HDF5 example files ===
40 40  
41 41  Here we have a few HDF5 samples (User data combined with Photon diagnostics data) from a few beamtimes showing the different kind options.
42 42  
43 -Example 1:  Images saved at FLASH2
91 +[[image:attach:image2019-10-21_17-2-50.png||thumbnail="true" width="300"]] [[download HDF5 (Images @ FL2)>>url:https://desycloud.desy.de/index.php/s/nyEgeCWJFC4gao2||shape="rect"]]
44 44  
45 45  \\
46 46  
47 -[[image:attach:image2019-10-21_17-2-50.png||thumbnail="true" height="150"]] [[download HDF5 (Images)>>url:https://desycloud.desy.de/index.php/s/nyEgeCWJFC4gao2||shape="rect"]]
95 +[[~[~[image:attach:image2019-10-22_10-52-27.png~|~|thumbnail="true" width="300"~]~]download HDF5 (GHz ADC and OPIS @ FL2)>>url:https://desycloud.desy.de/index.php/s/AeA2kPNNnZgX95A||shape="rect"]]
48 48  
49 49  \\
50 50  
51 51  \\
52 52  
53 -[[download HDF5 (GHz ADC and OPIS)>>url:https://desycloud.desy.de/index.php/s/AeA2kPNNnZgX95A||shape="rect"]]
54 -
55 -\\
56 -
57 -\\
58 -
59 59  [[Contents>>doc:||anchor="Contents"]]
60 60  
61 61  \\
62 62  
63 -\\
105 +== Most popular FLASH parameters and their names in HDF5, DOOCS and (raw) DAQ ==
64 64  
65 -== Most popular FLASH parameters and their names in HDF5, DOOCS and (raw) DAQ ==
107 +{{id name="DOOCSparameters"/}}
66 66  
67 67  The complete list for the relation between DOOCS names and HDF5 names for the recordable parameters can be found in [[DESY's Repository~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://stash.desy.de/projects/CS/repos/pah/browse/src/camp/data/channel2HdfName.dat||shape="rect"]].
68 68  The most common and often used ones are summarized below:
... ... @@ -143,23 +143,29 @@
143 143  \\
144 144  
145 145  
146 -NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact
188 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. For more Info contact your local contact
147 147  
148 148  [[Contents>>doc:||anchor="Contents"]]
149 149  
150 150  \\
151 151  
152 -==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) / Spectrometer (FLASH1) ====
194 +==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ====
153 153  
196 +\\
197 +
198 +(% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation  (VME + PhotonFlux ML server)**
199 +
154 154  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
155 -//always saved (PBD)//
156 -DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}}
157 -DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}
158 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)
201 +//always saved (PBD)//
202 +
203 +(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%)
204 +(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%)
205 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator (ion current)
159 159  units : microJ
160 160  
161 161  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
162 -//always saved (PBD)//
209 +//always saved (PBD)//
210 +
163 163  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}}
164 164  DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}}
165 165  desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -173,7 +173,8 @@
173 173  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
174 174  
175 175  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}}
176 -//always saved (PBD)//
224 +//always saved (PBD)//
225 +
177 177  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}}
178 178  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}}
179 179  desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current)
... ... @@ -180,7 +180,8 @@
180 180  units : microJ
181 181  
182 182  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}}
183 -//always saved (PBD)//
232 +//always saved (PBD)//
233 +
184 184  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}}
185 185  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}}
186 186  desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -193,6 +193,57 @@
193 193  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
194 194  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
195 195  
246 +\\
247 +
248 +(% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation  (MTCA, analog to FLASH2 and XFEL)**
249 +
250 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
251 +//always saved (PBD)//
252 +(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%)
253 +(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}}
254 +
255 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator
256 +units : microJ
257 +
258 +\\
259 +
260 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
261 +//always saved (PBD)//
262 +
263 +(% style="color: rgb(0,0,0);" %)DOOCS prop : 
264 +{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}
265 +
266 +desc : Energy per pulse measured in the Tunnel.  In addition measurement errors and beam position are included for EACH pulse in the pulse train  !! (see below)
267 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
268 +
269 +{{info title="GMD pulse resolved data structure"}}
270 +For every pulse in the pulse train the information is saved:
271 +
272 +
273 +1. **Intensity per pulse** (a.u. (more or less µJ ))
274 +1. Intensity per pulse (auxillary GMD) - not used
275 +1. Position horizontal (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
276 +1. Position vertical (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
277 +1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%))
278 +1. Position horizontal sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
279 +1. Position vertical sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
280 +1. Combined warning and error flags
281 +
282 +The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 
283 +file
284 +
285 +
286 +[[image:attach:image2021-2-9_10-51-6.png||height="250"]]
287 +
288 +\\
289 +{{/info}}
290 +
291 +All values for the GMD are also available for the** BDA GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between BDA and Tunnel signal shows the attenuation. **BUT NOTE** that the filter units  are downstream the GMD. So if filters  are used this influence is NOT measured by the GMD BDA !
292 +
293 +\\
294 +
295 +Besides  pulse energy the GMD also provides information about the beam position
296 +
196 196  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}}
197 197  //always saved (PBD)//
198 198  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
... ... @@ -221,6 +221,10 @@
221 221  desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical)
222 222  units : mm
223 223  
325 +\\
326 +
327 +==== Spectrometer (FLASH1) ====
328 +
224 224  {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}}
225 225  _always saved (when Spectrum is measured !!) (PBD) _
226 226  DOOCS prop : {{code language="none"}}TTF2.EXP/PHOTONWL.ML/WAVE_LENGTH/VAL.TD{{/code}}
... ... @@ -304,10 +304,25 @@
304 304  //always saved (PBD)//
305 305  DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
306 306  DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
307 -desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data)
308 -units: ps (bigger numbers indicate later arrivaltime of the electrons)
309 -note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
412 +desc: Electron bunch arrival time measured with the BAM inside the accelerator - however shows a very good correlation to the arrivaltime  of the XUV pulses in the experiment (pulse resolved data).
413 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
310 310  
415 +{{code language="none"}}/FL1/Electron Diagnostic/BAM/1SFELC/electron bunch arrival time (low charge){{/code}}
416 +//always saved (PBD)//
417 +DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/1SFELC/LOW_CHARGE_ARRIVAL_TIME{{/code}}
418 +DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/1SFELC.LOW_CHARGE_ARRIVAL_TIME{{/code}}
419 +desc: Electron bunch arrival time measured with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020.
420 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
421 +
422 +{{info title="BAM hints"}}
423 +* besides the arrivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved.In case of doubt ask your local contact
424 +* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
425 +* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
426 +* a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
427 +{{/info}}
428 +
429 +\\
430 +
311 311  ===== electron beam profile =====
312 312  
313 313  {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/TDS profile{{/code}}
... ... @@ -336,7 +336,7 @@
336 336  ===== electron bunch energy =====
337 337  
338 338  {{code language="none"}}/FL1/Electron Diagnostic/Electron energy/average electron energy{{/code}}
339 -_always saved (PBD)
459 +//always saved (PBD)//
340 340  DOOCS prop : {{code language="none"}}TTF2.DAQ/ENERGY.DOGLEG/E_INTRA_MEAN/VAL{{/code}}
341 341  DAQ channel: {{code language="none"}}PBD.ENERGY.DOGLEG/E_MEAN{{/code}}
342 342  desc: electron bunch energy (average over the bunch train)
... ... @@ -344,7 +344,7 @@
344 344  \\
345 345  
346 346  {{code language="none"}}/FL1/Electron Diagnostic/Electron energy/pulse resolved energy{{/code}}
347 -_always saved (PBD)
467 +//always saved (PBD)//
348 348  DOOCS prop : {{code language="none"}}TTF2.DAQ/ENERGY.DOGLEG/E_SPECT/VAL.TD{{/code}}
349 349  DAQ channel: {{code language="none"}}PBD.ENERGY.DOGLEG/E_SPECT{{/code}}
350 350  desc: electron bunch energy bunch resolved
... ... @@ -353,7 +353,7 @@
353 353  \\
354 354  
355 355  {{code language="none"}}/FL1/Electron Diagnostic/Electron energy/wavelength bunch train average{{/code}}
356 -_always saved (PBD)
476 +//always saved (PBD)//
357 357  DOOCS prop : {{code language="none"}}TTF2.DAQ/ENERGY.DOGLEG/LAMBDA_MEAN/VAL{{/code}}
358 358  DAQ channel: {{code language="none"}}PBD.ENERGY.DOGLEG/LAMBDA_MEAN{{/code}}
359 359  desc: Wavelength calculated by the electron bunch energy (average over the bunch train) (FLASH1)
... ... @@ -547,12 +547,12 @@
547 547  
548 548  ==== Beamline info (FLASH2) ====
549 549  
550 -(% style="color: rgb(255,153,0);" %)(not yet available){{code language="none"}}/FL2/Beamlines/Attenuator/pressure  {{/code}}(%%)
551 -(% style="color: rgb(193,199,208);" %)//always saved (PBD2)// (%%)
552 -(% style="color: rgb(193,199,208);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} (%%)
553 -(% style="color: rgb(193,199,208);" %)DAQ channel:  {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} (%%)
554 -(% style="color: rgb(193,199,208);" %)desc: set pressure in the gas attenuator (%%)
555 -(% style="color: rgb(193,199,208);" %)units: mbar(%%)
670 +{{code language="none"}}/FL2/Beamlines/Attenuator/pressure  {{/code}}
671 +(% style="color: rgb(0,0,0);" %)//always saved (PBD2)// (%%)
672 +(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} (%%)
673 +(% style="color: rgb(0,0,0);" %)DAQ channel:  {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} (%%)
674 +(% style="color: rgb(0,0,0);" %)desc: set pressure in the gas attenuator (%%)
675 +(% style="color: rgb(0,0,0);" %)units: mbar(%%)
556 556  \\
557 557  
558 558  {{code language="none"}}/FL2/Beamlines/FL20/Shutter/open{{/code}}
... ... @@ -571,11 +571,13 @@
571 571  units: degree
572 572  \\
573 573  
694 +/FL2/Beamlines/Filter wheel/position wheel 2
695 +always saved (PBD2)
696 +DOOCS prop : {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS{{/code}}
697 +DAQ channel: {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS{{/code}}
698 +desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filter wheels in FLASH1 and FLASH2.WebHome]]
699 +units: degree
574 574  
575 -//always saved (PBD2)//
576 -\\\\**[[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filter wheels in FLASH1 and FLASH2.WebHome]]**
577 -{{code language="none"}}/FL2/Beamlines/Filter wheel/position wheel 2 DOOCS prop : FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS desc: Position of the BL filter wheel 2 - to correlate with the filter material please look units: degree{{/code}}
578 -
579 579  \\
580 580  
581 581  NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact
... ... @@ -597,40 +597,37 @@
597 597  
598 598  \\
599 599  
600 -(% style="color: rgb(255,204,0);" %)average Sigma    to be included in
601 -
602 -(% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} (%%)
603 -(% style="color: rgb(193,199,208);" %)//always saved (PBD2)// (%%)
604 -(% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%)
605 -(% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%)
606 -(% style="color: rgb(193,199,208);" %)desc :  This parameter gives an indication of the error of the measurement of the average pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)
607 -(% style="color: rgb(193,199,208);" %)units : microJ
608 -
609 -\\
610 -
611 -\\
612 -
613 613  {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
614 614  //always saved (PBD2)//
615 615  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
616 616  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
617 -desc : Energy per pulse measured in the Tunnel  (in fromt of the gas attenuator and the apertures in the Hall)
726 +desc : Energy per pulse measured in the Tunnel  (in front of the gas attenuator and the apertures in the Hall) In addition measurement errors and beam position are included for EACH pulse in the pulse train  !! (see below)
618 618  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
619 619  
620 -\\
729 +{{info title="GMD pulse resolved data structure"}}
730 +For every pulse in the pulse train the information is saved:
731 +
621 621  
622 -\\
733 +1. **Intensity per pulse** (a.u. (more or less µJ ))
734 +1. Intensity per pulse (auxillary GMD) - not used
735 +1. Position horizontal (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
736 +1. Position vertical (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
737 +1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%))
738 +1. Position horizontal sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
739 +1. Position vertical sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
740 +1. Combined warning and error flags
623 623  
624 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel uncertainty (sigma){{/code}}
625 -//always saved (PBD2)//
626 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}}
627 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}}
628 -desc :(% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)
629 -units : a.u. (more or less µJ - related to the value of the pulse energy )
742 +The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 
743 +file
630 630  
745 +
746 +[[image:attach:image2021-2-9_10-51-6.png||height="250"]]
631 631  
632 -{{code language="none"}}{{/code}}
748 +\\
749 +{{/info}}
633 633  
751 +\\
752 +
634 634  All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall !
635 635  
636 636  \\
... ... @@ -657,13 +657,15 @@
657 657  
658 658  \\
659 659  
779 +/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel x
780 +always saved (PBD2)
781 +DOOCS prop : FLASH.FEL/XGM.BPM/FL2.HALL/X.TD
782 +DAQ channel: FLASH.FEL/XGM.BPM/FL2.HALL:2
783 +desc: Besides the well calibrated averaged beam position information there is also the option to measure the beam position on a single bunch level. HOWEVER this methide needs a perfectly adjusted signal level (talk to your local contact !!) and also then the signal to noise is rather small and one needs some averaging ... BUT with this option one can determine if there was a spatial slope on a burst (say forst bunches were lower than the last ones or so ...)
784 +units : mm   
660 660  
661 -//always saved (PBD2)//
662 -\\\\{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel x DOOCS prop : FLASH.FEL/XGM.BPM/FL2.HALL/X.TDDAQ channel: FLASH.FEL/XGM.BPM/FL2.HALL:2 desc: {{/code}}Besides the well calibrated averaged beam position information there is also the option
663 -{{code language="none"}}to measure the beam position on a single bunch level. HOWEVER this methide needs a perfectly adjusted signal level (talk to your local contact !!) and also then the signal to noise is rather small and one needs some averaging ... BUT with this option one can determine if there was a spatial slope on a burst (say forst bunches were lower than the last ones or so ...)units : mm    {{/code}}
786 +(x=horizontal, y = vertial)
664 664  
665 -{{code language="none"}}(x=horizontal, y = vertial){{/code}}
666 -
667 667  again the same parameter set is available for the **HALL GMD**
668 668  
669 669  \\
... ... @@ -749,17 +749,30 @@
749 749  =====
750 750  arrival time =====
751 751  
873 +{{code language="none"}}/FL2/Electron Diagnostic/BAM/8FL2XTDS/electron bunch arrival time (low charge){{/code}}
874 +//always saved (PBD2)//
875 +DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/8FL2XTDS/LOW_CHARGE_ARRIVAL_TIME{{/code}}
876 +DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/8FL2XTDS.LOW_CHARGE_ARRIVAL_TIME{{/code}}
877 +desc: Electron bunch arrival time measured with the BAM after the FLASH2 undulator (pulse resolved data)
878 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
879 +
752 752  **FL1**{{code language="none"}}//Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}}
753 753  //always saved (PBD2)//
754 754  DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
755 755  DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
756 -desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data)
884 +desc: Electron bunch arrival time measured with the BAM  in the accelerator  (pulse resolved data)
757 757  units: ps (bigger numbers indicate later arrivaltime of the electrons)
758 758  
759 -The BAM measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !). The first values are for FLASH1 bunches.
760 -After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ...
887 +\\
761 761  
762 -Docu for BAM:  [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
889 +{{info title="BAM hints"}}
890 +* The BAM 4DBC3 measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !).
891 +* The BAM 8FL2XTDS measures only for FLASH2 BUT has the same data structure as the other BAMS ... thus there are also (random) values in in the  FLASH1 time slot 
892 +** Structure: The first values are for FLASH1 bunches. After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... .In case of doubt ask your local contact
893 +* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
894 +* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
895 +* a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
896 +{{/info}}
763 763  
764 764  
765 765  [[Contents>>doc:||anchor="Contents"]]
... ... @@ -1051,65 +1051,6 @@
1051 1051  
1052 1052  \\
1053 1053  
1054 -=== Samples how to read HDF5 with Matlab ===
1055 -
1056 -The examples apply to HDF files with HDF tree version before vers. 0.3.0.
1057 -
1058 -(% style="color: rgb(0,128,0);" %)%% read in the needed data p=path; path(p,'D:\mess-daten\DAQ-data\hdf5\Gotthard') % add the actual folder to the path hdf5file='FLASH1_EXP-2016-03-16T1420.h5'; % data with Gotthard and VLS
1059 -
1060 -(% style="color: rgb(0,128,0);" %)% h5disp(hdf5file,'/','min') % to get an idea what is in the file % h5info(hdf5file,'/Experiment/Gotthard1/BL.0') % get info about the individual channel
1061 -
1062 -(% style="color: rgb(0,128,0);" %)% read a Number per 10 Hz pulse train:
1063 -
1064 -(% class="code" %)
1065 -(((
1066 -FEL_Wavelength_energy_server=h5read(hdf5file,'/Photon Diagnostic/Wavelength/Calculated by energy/wavelength' );
1067 -)))
1068 -
1069 -(% style="color: rgb(0,128,0);" %)% read in a 1D array (spectrum) %GMD data GMD_Spectrum=h5read(hdf5file,'/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA');
1070 -
1071 -(% style="color: rgb(0,128,0);" %)% This reads in all the data . One can also limit the amount of data read to a subset of the data stored in the file. e.g. for image Data (Gotthard)
1072 -
1073 -\\
1074 -
1075 -(% class="code" %)
1076 -(((
1077 -Start_event= 500 ; % define the first 10 Hz event
1078 - Number_of_events = 20; % how many 10 Hz events to load
1079 -)))
1080 -
1081 -(% style="color: rgb(0,128,0);" %)% read only part of the data:
1082 -
1083 -(% class="code" %)
1084 -(((
1085 -Gotthard_data=h5read(hdf5file,'/Experiment/Gotthard1/BL.0',[2 650 Start_event],[50 85 Number_of_events]);
1086 -)))
1087 -
1088 -(% style="color: rgb(0,128,0);" %)% start stop increment "manual" for 2 D data : [start bunch number in Gotthard data start pixelin spectrum start sample in 10 Hz trains], % [number of bunches in the Gotthard data number of points in the spectrum number of spectra ]
1089 -
1090 -(% class="code" %)
1091 -(((
1092 -VLS_Spectrum=h5read(hdf5file,'/Photon Diagnostic/Wavelength/VLS online spectrometer/PCO.ROI.X',[400 Start_event],[200 Number_of_events] );
1093 -
1094 -)))
1095 -
1096 -(% style="color: rgb(0,128,0);" %)% start stop increment "manual" for 1D data : [start sample in the spectrum start sample in 10 Hz trains],[number of points in the spectrum number of spectra ]
1097 -
1098 -(% style="color: rgb(0,128,0);" %)%GMD data
1099 -
1100 -(% class="code" %)
1101 -(((
1102 -GMD_Spectrum=h5read(hdf5file,'/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA',[1 Start_event],[40 Number_of_events] );
1103 -)))
1104 -
1105 -[[Contents>>doc:||anchor="Contents"]]
1106 -
1107 -=== How to read HDF5 with Python via FLASHH5 ===
1108 -
1109 -With [[FlashH5>>doc:FLASHUSER.FLASHH5 for easier access of FLASH's HDF5 files]] we provide h5py based examples to access and evaluate FLASH's HDF5 files.
1110 -
1111 -\\
1112 -
1113 1113  == HDF5 and DOOCS ==
1114 1114  
1115 1115  Here is an outdated [[list with the available properties that are always saved (PBD) for FLASH1 as>>attach:FLASH1__DaqChannel2HdfNamePbd.xlsx]] HDF5 names and the corresponding DOOCS names