Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 31.1
edited by erkben
on 2020/06/16 11:01
Change comment: There is no comment for this version
To version 39.1
edited by sndueste
on 2021/02/09 11:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.erkben
1 +XWiki.sndueste
Content
... ... @@ -8,9 +8,9 @@
8 8  
9 9  == General information about HDF5 ==
10 10  
11 -HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://www.hdfgroup.org/HDF5/||shape="rect"]]
11 +HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://portal.hdfgroup.org/display/support||shape="rect"]]
12 12  
13 -To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://support.hdfgroup.org/products/java/hdfview/index.html||shape="rect"]]
13 +To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://portal.hdfgroup.org/display/support/Download+HDFView||shape="rect"]]
14 14  
15 15  For use on the DESY Maxwell or PAL (max-fsc or pal) **hdfview** is available in the xray module :
16 16  {{code language="none"}}> module load xray{{/code}}
... ... @@ -18,9 +18,9 @@
18 18  
19 19  [[Contents>>doc:||anchor="Contents"]]
20 20  
21 -== FLASH HDF5 structure ==
21 +== The current FLASH HDF5 structure ==
22 22  
23 -The photon diagnostic, electron diagnostic and beamline information as well as the information about the pump-probe laser and the infrastructure offered for users (GHz/MHz ADCs) can be included in one HDF5 file which is organised according to train IDs. The general structure is:
23 +The photon diagnostic, electron diagnostic and beamline information as well as the information about the pump-probe laser and the infrastructure offered for users (GHz/MHz ADCs) can be included in one HDF5 file which is organized according to train IDs. The general structure is:
24 24  
25 25  * Electron Diagnostic
26 26  * Photon Diagnostics
... ... @@ -27,16 +27,16 @@
27 27  * Beamlines
28 28  * Experiment
29 29  * Timing
30 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/HDF5main/HDF5_structure.jpg~|~|alt="HDF5_structure.jpg" width="700" height="500"~]~]>>attach:HDF5_structure.jpg]]
30 +[[image:attach:HDF5_structure.jpg||height="400"]]
31 31  
32 -A detailled description of (most) channels can be found in the lower part of the hdf5 viewer:
33 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/HDF5main/HDF5_structure_desc.jpg~|~|alt="HDF5_structure_desc.jpg" width="341" height="413"~]~]>>attach:HDF5_structure_desc.jpg]]
32 +A detailed description of (most) channels can be found in the lower part of the hdf5 viewer:
33 +[[image:attach:HDF5_structure_desc.jpg||thumbnail="true" height="250"]]
34 34  
35 35  [[Contents>>doc:||anchor="Contents"]]
36 36  
37 37  \\
38 38  
39 -== HDF5 example files ==
39 +=== HDF5 example files ===
40 40  
41 41  Here we have a few HDF5 samples (User data combined with Photon diagnostics data) from a few beamtimes showing the different kind options.
42 42  
... ... @@ -54,8 +54,14 @@
54 54  
55 55  \\
56 56  
57 +== The new (starting 2021) HDF5 format ==
58 +
59 +Here is [[some documentation on the changes of the HDF5 format>>doc:FLASHUSER.HDF5 format]] that well be available in 2021 (work in progress)
60 +
57 57  \\
58 58  
63 +\\
64 +
59 59  == Most popular FLASH parameters and their names in HDF5, DOOCS and (raw) DAQ ==
60 60  
61 61  {{id name="DOOCSparameters"/}}
... ... @@ -139,23 +139,29 @@
139 139  \\
140 140  
141 141  
142 -NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact
148 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. For more Info contact your local contact
143 143  
144 144  [[Contents>>doc:||anchor="Contents"]]
145 145  
146 146  \\
147 147  
148 -==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) / Spectrometer (FLASH1) ====
154 +==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ====
149 149  
156 +\\
157 +
158 +(% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation  (VME + PhotonFlux ML server)**
159 +
150 150  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
151 -//always saved (PBD)//
152 -DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}}
153 -DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}
154 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)
161 +//always saved (PBD)//\\
162 +
163 +(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%)
164 +(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%)
165 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator (ion current)
155 155  units : microJ
156 156  
157 157  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
158 -//always saved (PBD)//
169 +//always saved (PBD)//
170 +
159 159  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}}
160 160  DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}}
161 161  desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -169,7 +169,8 @@
169 169  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
170 170  
171 171  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}}
172 -//always saved (PBD)//
184 +//always saved (PBD)//
185 +
173 173  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}}
174 174  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}}
175 175  desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current)
... ... @@ -176,7 +176,8 @@
176 176  units : microJ
177 177  
178 178  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}}
179 -//always saved (PBD)//
192 +//always saved (PBD)//
193 +
180 180  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}}
181 181  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}}
182 182  desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -189,6 +189,57 @@
189 189  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
190 190  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
191 191  
206 +\\
207 +
208 +(% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation  (MTCA, analog to FLASH2 and XFEL)**
209 +
210 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
211 +//always saved (PBD)//
212 +(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%)
213 +(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}}
214 +
215 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator
216 +units : microJ
217 +
218 +\\
219 +
220 +{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
221 +//always saved (PBD)//
222 +
223 +(% style="color: rgb(0,0,0);" %)DOOCS prop : 
224 +{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}
225 +
226 +desc : Energy per pulse measured in the Tunnel.  In addition measurement errors and beam position are included for EACH pulse in the pulse train  !! (see below)
227 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
228 +
229 +{{info title="GMD pulse resolved data structure"}}
230 +For every pulse in the pulse train the information is saved:
231 +
232 +
233 +1. **Intensity per pulse** (a.u. (more or less µJ ))
234 +1. Intensity per pulse (auxillary GMD) - not used
235 +1. Position horizontal (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
236 +1. Position vertical (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
237 +1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%))
238 +1. Position horizontal sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
239 +1. Position vertical sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
240 +1. Combined warning and error flags
241 +
242 +The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 
243 +file
244 +
245 +
246 +[[image:attach:image2021-2-9_10-51-6.png||height="250"]]
247 +
248 +\\
249 +{{/info}}
250 +
251 +All values for the GMD are also available for the** BDA GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between BDA and Tunnel signal shows the attenuation. **BUT NOTE** that the filter units  are downstream the GMD. So if filters  are used this influence is NOT measured by the GMD BDA !
252 +
253 +\\
254 +
255 +Besides  pulse energy the GMD also provides information about the beam position
256 +
192 192  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}}
193 193  //always saved (PBD)//
194 194  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
... ... @@ -217,6 +217,10 @@
217 217  desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical)
218 218  units : mm
219 219  
285 +\\
286 +
287 +==== Spectrometer (FLASH1) ====
288 +
220 220  {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}}
221 221  _always saved (when Spectrum is measured !!) (PBD) _
222 222  DOOCS prop : {{code language="none"}}TTF2.EXP/PHOTONWL.ML/WAVE_LENGTH/VAL.TD{{/code}}
... ... @@ -300,10 +300,25 @@
300 300  //always saved (PBD)//
301 301  DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
302 302  DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
303 -desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data)
304 -units: ps (bigger numbers indicate later arrivaltime of the electrons)
305 -note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
372 +desc: Electron bunch arrival time measured with the BAM inside the accelerator - however shows a very good correlation to the arrivaltime  of the XUV pulses in the experiment (pulse resolved data).
373 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
306 306  
375 +{{code language="none"}}/FL1/Electron Diagnostic/BAM/1SFELC/electron bunch arrival time (low charge){{/code}}
376 +//always saved (PBD)//
377 +DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/1SFELC/LOW_CHARGE_ARRIVAL_TIME{{/code}}
378 +DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/1SFELC.LOW_CHARGE_ARRIVAL_TIME{{/code}}
379 +desc: Electron bunch arrival time measured with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020.
380 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
381 +
382 +{{info title="BAM hints"}}
383 +* besides the arrivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved.In case of doubt ask your local contact
384 +* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
385 +* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
386 +* a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
387 +{{/info}}
388 +
389 +\\
390 +
307 307  ===== electron beam profile =====
308 308  
309 309  {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/TDS profile{{/code}}
... ... @@ -593,40 +593,37 @@
593 593  
594 594  \\
595 595  
596 -(% style="color: rgb(255,204,0);" %)average Sigma    to be included in
597 -
598 -(% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} (%%)
599 -(% style="color: rgb(193,199,208);" %)//always saved (PBD2)// (%%)
600 -(% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%)
601 -(% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%)
602 -(% style="color: rgb(193,199,208);" %)desc :  This parameter gives an indication of the error of the measurement of the average pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)
603 -(% style="color: rgb(193,199,208);" %)units : microJ
604 -
605 -\\
606 -
607 -\\
608 -
609 609  {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
610 610  //always saved (PBD2)//
611 611  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
612 612  DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
613 -desc : Energy per pulse measured in the Tunnel  (in fromt of the gas attenuator and the apertures in the Hall)
684 +desc : Energy per pulse measured in the Tunnel  (in front of the gas attenuator and the apertures in the Hall) In addition measurement errors and beam position are included for EACH pulse in the pulse train  !! (see below)
614 614  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
615 615  
616 -\\
687 +{{info title="GMD pulse resolved data structure"}}
688 +For every pulse in the pulse train the information is saved:
689 +
617 617  
618 -\\
691 +1. **Intensity per pulse** (a.u. (more or less µJ ))
692 +1. Intensity per pulse (auxillary GMD) - not used
693 +1. Position horizontal (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
694 +1. Position vertical (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
695 +1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%))
696 +1. Position horizontal sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
697 +1. Position vertical sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
698 +1. Combined warning and error flags
619 619  
620 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel uncertainty (sigma){{/code}}
621 -//always saved (PBD2)//
622 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}}
623 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}}
624 -desc :(% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)
625 -units : a.u. (more or less µJ - related to the value of the pulse energy )
700 +The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 
701 +file
626 626  
703 +
704 +[[image:attach:image2021-2-9_10-51-6.png||height="250"]]
627 627  
628 -{{code language="none"}}{{/code}}
706 +\\
707 +{{/info}}
629 629  
709 +\\
710 +
630 630  All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall !
631 631  
632 632  \\
... ... @@ -745,17 +745,30 @@
745 745  =====
746 746  arrival time =====
747 747  
829 +{{code language="none"}}/FL2/Electron Diagnostic/BAM/8FL2XTDS/electron bunch arrival time (low charge){{/code}}
830 +//always saved (PBD2)//
831 +DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/8FL2XTDS/LOW_CHARGE_ARRIVAL_TIME{{/code}}
832 +DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/8FL2XTDS.LOW_CHARGE_ARRIVAL_TIME{{/code}}
833 +desc: Electron bunch arrival time measured with the BAM after the FLASH2 undulator (pulse resolved data)
834 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
835 +
748 748  **FL1**{{code language="none"}}//Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}}
749 749  //always saved (PBD2)//
750 750  DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
751 751  DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
752 -desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data)
840 +desc: Electron bunch arrival time measured with the BAM  in the accelerator  (pulse resolved data)
753 753  units: ps (bigger numbers indicate later arrivaltime of the electrons)
754 754  
755 -The BAM measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !). The first values are for FLASH1 bunches.
756 -After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ...
843 +\\
757 757  
758 -Docu for BAM:  [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
845 +{{info title="BAM hints"}}
846 +* The BAM 4DBC3 measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !).
847 +* The BAM 8FL2XTDS measures only for FLASH2 BUT has the same data structure as the other BAMS ... thus there are also (random) values in in the  FLASH1 time slot 
848 +** Structure: The first values are for FLASH1 bunches. After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... .In case of doubt ask your local contact
849 +* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
850 +* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
851 +* a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
852 +{{/info}}
759 759  
760 760  
761 761  [[Contents>>doc:||anchor="Contents"]]
... ... @@ -1100,10 +1100,6 @@
1100 1100  
1101 1101  [[Contents>>doc:||anchor="Contents"]]
1102 1102  
1103 -=== How to read HDF5 with Python via FLASHH5 ===
1104 -
1105 -With [[FlashH5>>doc:FLASHUSER.FLASHH5 for easier access of FLASH's HDF5 files]] we provide h5py based examples to access and evaluate FLASH's HDF5 files.
1106 -
1107 1107  \\
1108 1108  
1109 1109  == HDF5 and DOOCS ==