Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 34.1
edited by sndueste
on 2020/10/28 16:14
Change comment: There is no comment for this version
To version 32.1
edited by erkben
on 2020/06/16 11:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.sndueste
1 +XWiki.erkben
Content
... ... @@ -139,7 +139,7 @@
139 139  \\
140 140  
141 141  
142 -NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. For more Info contact your local contact
142 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact
143 143  
144 144  [[Contents>>doc:||anchor="Contents"]]
145 145  
... ... @@ -149,20 +149,13 @@
149 149  
150 150  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
151 151  //always saved (PBD)//
152 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%)
153 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}}
154 -
155 -(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%)
156 -(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%)
157 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator (ion current)
152 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}}
153 +DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}
154 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)
158 158  units : microJ
159 159  
160 160  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
161 -//always saved (PBD)//
162 -
163 -(% style="color: rgb(193,199,208);" %)New MTCA Version: DOOCS prop : 
164 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}
165 -
158 +//always saved (PBD)//
166 166  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}}
167 167  DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}}
168 168  desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -176,11 +176,7 @@
176 176  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
177 177  
178 178  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}}
179 -//always saved (PBD)//
180 -
181 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.BDA/PHOTONFLUX.UJ{{/code}} (%%)
182 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.BDA/PHOTONFLUX.UJ{{/code}}
183 -
172 +//always saved (PBD)//
184 184  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}}
185 185  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}}
186 186  desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current)
... ... @@ -187,10 +187,7 @@
187 187  units : microJ
188 188  
189 189  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}}
190 -//always saved (PBD)//
191 -
192 -(% style="color: rgb(193,199,208);" %)New MTCA Version: DOOCS prop : 
193 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.BDA/INTENSITY.TD{{/code}}New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.BDA/INTENSITY.TD{{/code}}(%%)
179 +//always saved (PBD)//
194 194  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}}
195 195  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}}
196 196  desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -203,8 +203,6 @@
203 203  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
204 204  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
205 205  
206 -\\
207 -
208 208  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}}
209 209  //always saved (PBD)//
210 210  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
... ... @@ -316,25 +316,10 @@
316 316  //always saved (PBD)//
317 317  DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
318 318  DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
319 -desc: Electron bunch arrival time measured with the BAM inside the accelerator - however shows a very good correlation to the arrivaltime  of the XUV pulses in the experiment (pulse resolved data).
320 -units: ps (bigger numbers indicate later arrivaltime of the electrons)
303 +desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data)
304 +units: ps (bigger numbers indicate later arrivaltime of the electrons)
305 +note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
321 321  
322 -{{code language="none"}}/FL1/Electron Diagnostic/BAM/1SFELC/electron bunch arrival time (low charge){{/code}}
323 -//always saved (PBD)//
324 -DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/1SFELC/LOW_CHARGE_ARRIVAL_TIME{{/code}}
325 -DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/1SFELC.LOW_CHARGE_ARRIVAL_TIME{{/code}}
326 -desc: Electron bunch arrival time measured with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020.
327 -units: ps (bigger numbers indicate later arrivaltime of the electrons)
328 -
329 -{{info title="BAM hints"}}
330 -* besides the arrivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved.In case of doubt ask your local contact
331 -* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
332 -* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
333 -* a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
334 -{{/info}}
335 -
336 -\\
337 -
338 338  ===== electron beam profile =====
339 339  
340 340  {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/TDS profile{{/code}}
... ... @@ -776,30 +776,17 @@
776 776  =====
777 777  arrival time =====
778 778  
779 -{{code language="none"}}/FL2/Electron Diagnostic/BAM/8FL2XTDS/electron bunch arrival time (low charge){{/code}}
780 -//always saved (PBD2)//
781 -DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/8FL2XTDS/LOW_CHARGE_ARRIVAL_TIME{{/code}}
782 -DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/8FL2XTDS.LOW_CHARGE_ARRIVAL_TIME{{/code}}
783 -desc: Electron bunch arrival time measured with the BAM after the FLASH2 undulator (pulse resolved data)
784 -units: ps (bigger numbers indicate later arrivaltime of the electrons)
785 -
786 786  **FL1**{{code language="none"}}//Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}}
787 787  //always saved (PBD2)//
788 788  DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
789 789  DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
790 -desc: Electron bunch arrival time measured with the BAM  in the accelerator  (pulse resolved data)
752 +desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data)
791 791  units: ps (bigger numbers indicate later arrivaltime of the electrons)
792 792  
793 -\\
755 +The BAM measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !). The first values are for FLASH1 bunches.
756 +After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ...
794 794  
795 -{{info title="BAM hints"}}
796 -* The BAM 4DBC3 measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !).
797 -* The BAM 8FL2XTDS measures only for FLASH2 BUT has the same data structure as the other BAMS ... thus there are also (random) values in in the  FLASH1 time slot 
798 -** Structure: The first values are for FLASH1 bunches. After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... .In case of doubt ask your local contact
799 -* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
800 -* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
801 -* a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
802 -{{/info}}
758 +Docu for BAM:  [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
803 803  
804 804  
805 805  [[Contents>>doc:||anchor="Contents"]]