... ... @@ -139,7 +139,7 @@
139 139  \\
140 140  
141 141  
142 -NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. For more Info contact your local contact
142 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact
143 143  
144 144  [[Contents>>doc:||anchor="Contents"]]
145 145  
... ... @@ -149,20 +149,13 @@
149 149  
150 150  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
151 151  //always saved (PBD)//
152 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%)
153 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}}
154 -
155 -(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%)
156 -(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%)
157 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator (ion current)
152 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}}
153 +DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}
154 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)
158 158  units : microJ
159 159  
160 160  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
161 -//always saved (PBD)//
162 -
163 -(% style="color: rgb(193,199,208);" %)New MTCA Version: DOOCS prop : 
164 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}
165 -
158 +//always saved (PBD)//
166 166  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}}
167 167  DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}}
168 168  desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -176,11 +176,7 @@
176 176  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
177 177  
178 178  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}}
179 -//always saved (PBD)//
180 -
181 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.BDA/PHOTONFLUX.UJ{{/code}} (%%)
182 -(% style="color: rgb(165,173,186);" %)New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.BDA/PHOTONFLUX.UJ{{/code}}
183 -
172 +//always saved (PBD)//
184 184  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}}
185 185  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}}
186 186  desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current)
... ... @@ -187,10 +187,7 @@
187 187  units : microJ
188 188  
189 189  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}}
190 -//always saved (PBD)//
191 -
192 -(% style="color: rgb(193,199,208);" %)New MTCA Version: DOOCS prop : 
193 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.BDA/INTENSITY.TD{{/code}}New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.BDA/INTENSITY.TD{{/code}}(%%)
179 +//always saved (PBD)//
194 194  DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}}
195 195  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}}
196 196  desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL
... ... @@ -203,8 +203,6 @@
203 203  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
204 204  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
205 205  
206 -\\
207 -
208 208  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}}
209 209  //always saved (PBD)//
210 210  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}