Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. cpassow1 +XWiki.sndueste - Content
-
... ... @@ -630,38 +630,32 @@ 630 630 631 631 \\ 632 632 633 -(% style="color: rgb(255,204,0);" %)average Sigma to be included in 634 - 635 -(% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} (%%) 636 -(% style="color: rgb(193,199,208);" %)//always saved (PBD2)// (%%) 637 -(% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%) 638 -(% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%) 639 -(% style="color: rgb(193,199,208);" %)desc : This parameter gives an indication of the error of the measurement of the average pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%) 640 -(% style="color: rgb(193,199,208);" %)units : microJ 641 - 642 -\\ 643 - 644 -\\ 645 - 646 646 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 647 647 //always saved (PBD2)// 648 648 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}} 649 649 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}} 650 -desc : Energy per pulse measured in the Tunnel (in fro mt of the gas attenuator and the apertures in the Hall)637 +desc : Energy per pulse measured in the Tunnel (in front of the gas attenuator and the apertures in the Hall) In addition measurement errors and beam position are included for EACH pulse in the pulse train !! (see below) 651 651 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 652 652 653 -\\ 640 +For every pulse in the pulse train the information is saved: 641 + 654 654 655 -\\ 643 +1. **Intensity per pulse** (a.u. (more or less µJ )) 644 +1. Intensity per pulse (auxillary GMD) - not used 645 +1. Position horizontal (mm, for a single pulse the position informytion may be very noisy - talk to your local contact) 646 +1. Position vertical (mm, for a single pulse the position informytion may be very noisy - talk to your local contact) 647 +1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)) 648 +1. Position horizontal sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 649 +1. Position vertical sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 650 +1. Combined warning and error flags 656 656 657 -{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel uncertainty (sigma){{/code}} 658 -//always saved (PBD2)// 659 -DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}} 660 -DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}} 661 -desc :(% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%) 662 -units : a.u. (more or less µJ - related to the value of the pulse energy ) 652 +The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 653 +file 663 663 655 + 656 +[[image:attach:image2021-2-9_10-51-6.png||height="250"]] 664 664 658 + 665 665 {{code language="none"}}{{/code}} 666 666 667 667 All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall !