Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,9 +8,9 @@ 8 8 9 9 == General information about HDF5 == 10 10 11 -HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https:// portal.hdfgroup.org/display/support||shape="rect"]]11 +HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://www.hdfgroup.org/HDF5/||shape="rect"]] 12 12 13 -To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://port al.hdfgroup.org/display/support/Download+HDFView||shape="rect"]]13 +To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://support.hdfgroup.org/products/java/hdfview/index.html||shape="rect"]] 14 14 15 15 For use on the DESY Maxwell or PAL (max-fsc or pal) **hdfview** is available in the xray module : 16 16 {{code language="none"}}> module load xray{{/code}} ... ... @@ -18,9 +18,9 @@ 18 18 19 19 [[Contents>>doc:||anchor="Contents"]] 20 20 21 -== The currentFLASH HDF5 structure ==21 +== FLASH HDF5 structure == 22 22 23 -The photon diagnostic, electron diagnostic and beamline information as well as the information about the pump-probe laser and the infrastructure offered for users (GHz/MHz ADCs) can be included in one HDF5 file which is organi zed according to train IDs. The general structure is:23 +The photon diagnostic, electron diagnostic and beamline information as well as the information about the pump-probe laser and the infrastructure offered for users (GHz/MHz ADCs) can be included in one HDF5 file which is organised according to train IDs. The general structure is: 24 24 25 25 * Electron Diagnostic 26 26 * Photon Diagnostics ... ... @@ -27,16 +27,16 @@ 27 27 * Beamlines 28 28 * Experiment 29 29 * Timing 30 -[[image: attach:HDF5_structure.jpg||height="400"]]30 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/HDF5main/HDF5_structure.jpg~|~|alt="HDF5_structure.jpg" width="700" height="500"~]~]>>attach:HDF5_structure.jpg]] 31 31 32 -A detailed description of (most) channels can be found in the lower part of the hdf5 viewer: 33 -[[image: attach:HDF5_structure_desc.jpg||thumbnail="true" height="250"]]32 +A detailled description of (most) channels can be found in the lower part of the hdf5 viewer: 33 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/HDF5main/HDF5_structure_desc.jpg~|~|alt="HDF5_structure_desc.jpg" width="341" height="413"~]~]>>attach:HDF5_structure_desc.jpg]] 34 34 35 35 [[Contents>>doc:||anchor="Contents"]] 36 36 37 37 \\ 38 38 39 -== =HDF5 example files ===39 +== HDF5 example files == 40 40 41 41 Here we have a few HDF5 samples (User data combined with Photon diagnostics data) from a few beamtimes showing the different kind options. 42 42 ... ... @@ -54,18 +54,10 @@ 54 54 55 55 \\ 56 56 57 -== The new (starting 2021) HDF5 format == 58 - 59 -Here is [[some documentation on the changes of the HDF5 format>>doc:FLASHUSER.HDF5 format]] that well be available in 2021 (work in progress) 60 - 61 61 \\ 62 62 63 - \\59 +== Most popular FLASH parameters and their names in HDF5, DOOCS and (raw) DAQ == 64 64 65 -== Most popular FLASH parameters and their names in HDF5, DOOCS and (raw) DAQ == 66 - 67 -{{id name="DOOCSparameters"/}} 68 - 69 69 The complete list for the relation between DOOCS names and HDF5 names for the recordable parameters can be found in [[DESY's Repository~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://stash.desy.de/projects/CS/repos/pah/browse/src/camp/data/channel2HdfName.dat||shape="rect"]]. 70 70 The most common and often used ones are summarized below: 71 71 ... ... @@ -145,29 +145,23 @@ 145 145 \\ 146 146 147 147 148 -NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. For more Info contact your local contact140 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact 149 149 150 150 [[Contents>>doc:||anchor="Contents"]] 151 151 152 152 \\ 153 153 154 -==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ==== 146 +==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) / Spectrometer (FLASH1) ==== 155 155 156 -\\ 157 - 158 -(% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation (VME + PhotonFlux ML server)** 159 - 160 160 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 161 -//always saved (PBD)//\\ 162 - 163 -(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%) 164 -(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%) 165 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator (ion current) 149 +//always saved (PBD)// 150 +DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} 151 +DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}} 152 +desc : calibrated average SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current) 166 166 units : microJ 167 167 168 168 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 169 -//always saved (PBD)// 170 - 156 +//always saved (PBD)// 171 171 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}} 172 172 DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}} 173 173 desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL ... ... @@ -181,8 +181,7 @@ 181 181 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 182 182 183 183 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}} 184 -//always saved (PBD)// 185 - 170 +//always saved (PBD)// 186 186 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}} 187 187 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}} 188 188 desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current) ... ... @@ -189,8 +189,7 @@ 189 189 units : microJ 190 190 191 191 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}} 192 -//always saved (PBD)// 193 - 177 +//always saved (PBD)// 194 194 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}} 195 195 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}} 196 196 desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL ... ... @@ -203,57 +203,6 @@ 203 203 desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 204 204 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 205 205 206 -\\ 207 - 208 -(% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation (MTCA, analog to FLASH2 and XFEL)** 209 - 210 -{{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 211 -//always saved (PBD)// 212 -(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%) 213 -(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} 214 - 215 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator 216 -units : microJ 217 - 218 -\\ 219 - 220 -{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 221 -//always saved (PBD)// 222 - 223 -(% style="color: rgb(0,0,0);" %)DOOCS prop : 224 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}} 225 - 226 -desc : Energy per pulse measured in the Tunnel. In addition measurement errors and beam position are included for EACH pulse in the pulse train !! (see below) 227 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 228 - 229 -{{info title="GMD pulse resolved data structure"}} 230 -For every pulse in the pulse train the information is saved: 231 - 232 - 233 -1. **Intensity per pulse** (a.u. (more or less µJ )) 234 -1. Intensity per pulse (auxillary GMD) - not used 235 -1. Position horizontal (mm, for a single pulse the position information may be very noisy - talk to your local contact) 236 -1. Position vertical (mm, for a single pulse the position information may be very noisy - talk to your local contact) 237 -1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)) 238 -1. Position horizontal sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 239 -1. Position vertical sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 240 -1. Combined warning and error flags 241 - 242 -The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 243 -file 244 - 245 - 246 -[[image:attach:image2021-2-9_10-51-6.png||height="250"]] 247 - 248 -\\ 249 -{{/info}} 250 - 251 -All values for the GMD are also available for the** BDA GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between BDA and Tunnel signal shows the attenuation. **BUT NOTE** that the filter units are downstream the GMD. So if filters are used this influence is NOT measured by the GMD BDA ! 252 - 253 -\\ 254 - 255 -Besides pulse energy the GMD also provides information about the beam position 256 - 257 257 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}} 258 258 //always saved (PBD)// 259 259 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} ... ... @@ -282,10 +282,6 @@ 282 282 desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical) 283 283 units : mm 284 284 285 -\\ 286 - 287 -==== Spectrometer (FLASH1) ==== 288 - 289 289 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}} 290 290 _always saved (when Spectrum is measured !!) (PBD) _ 291 291 DOOCS prop : {{code language="none"}}TTF2.EXP/PHOTONWL.ML/WAVE_LENGTH/VAL.TD{{/code}} ... ... @@ -369,25 +369,10 @@ 369 369 //always saved (PBD)// 370 370 DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}} 371 371 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}} 372 -desc: Electron bunch arrival time measured with the BAM inside the accelerator - however shows a very good correlation to the arrivaltime of the XUV pulses in the experiment (pulse resolved data). 373 -units: ps (bigger numbers indicate later arrivaltime of the electrons) 301 +desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data) 302 +units: ps (bigger numbers indicate later arrivaltime of the electrons) 303 +note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]] 374 374 375 -{{code language="none"}}/FL1/Electron Diagnostic/BAM/1SFELC/electron bunch arrival time (low charge){{/code}} 376 -//always saved (PBD)// 377 -DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/1SFELC/LOW_CHARGE_ARRIVAL_TIME{{/code}} 378 -DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/1SFELC.LOW_CHARGE_ARRIVAL_TIME{{/code}} 379 -desc: Electron bunch arrival time measured with the BAM before the undulator (pulse resolved data). This one was newly installed in 2020. 380 -units: ps (bigger numbers indicate later arrivaltime of the electrons) 381 - 382 -{{info title="BAM hints"}} 383 -* besides the arrivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved.In case of doubt ask your local contact 384 -* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]] 385 -* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] 386 -* a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]] 387 -{{/info}} 388 - 389 -\\ 390 - 391 391 ===== electron beam profile ===== 392 392 393 393 {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/TDS profile{{/code}} ... ... @@ -677,37 +677,40 @@ 677 677 678 678 \\ 679 679 594 +(% style="color: rgb(255,204,0);" %)average Sigma to be included in 595 + 596 +(% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} (%%) 597 +(% style="color: rgb(193,199,208);" %)//always saved (PBD2)// (%%) 598 +(% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%) 599 +(% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%) 600 +(% style="color: rgb(193,199,208);" %)desc : This parameter gives an indication of the error of the measurement of the average pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%) 601 +(% style="color: rgb(193,199,208);" %)units : microJ 602 + 603 +\\ 604 + 605 +\\ 606 + 680 680 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 681 681 //always saved (PBD2)// 682 682 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}} 683 683 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}} 684 -desc : Energy per pulse measured in the Tunnel (in fro nt of the gas attenuator and the apertures in the Hall)In addition measurement errors and beam position are included for EACH pulse in the pulse train !! (see below)611 +desc : Energy per pulse measured in the Tunnel (in fromt of the gas attenuator and the apertures in the Hall) 685 685 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 686 686 687 -{{info title="GMD pulse resolved data structure"}} 688 -For every pulse in the pulse train the information is saved: 689 - 614 +\\ 690 690 691 -1. **Intensity per pulse** (a.u. (more or less µJ )) 692 -1. Intensity per pulse (auxillary GMD) - not used 693 -1. Position horizontal (mm, for a single pulse the position information may be very noisy - talk to your local contact) 694 -1. Position vertical (mm, for a single pulse the position information may be very noisy - talk to your local contact) 695 -1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)) 696 -1. Position horizontal sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 697 -1. Position vertical sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 698 -1. Combined warning and error flags 616 +\\ 699 699 700 -The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 701 -file 618 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel uncertainty (sigma){{/code}} 619 +//always saved (PBD2)// 620 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}} 621 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}} 622 +desc :(% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%) 623 +units : a.u. (more or less µJ - related to the value of the pulse energy ) 702 702 703 - 704 -[[image:attach:image2021-2-9_10-51-6.png||height="250"]] 705 705 706 -\\ 707 -{{/info}} 626 +{{code language="none"}}{{/code}} 708 708 709 -\\ 710 - 711 711 All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall ! 712 712 713 713 \\ ... ... @@ -826,30 +826,17 @@ 826 826 ===== 827 827 arrival time ===== 828 828 829 -{{code language="none"}}/FL2/Electron Diagnostic/BAM/8FL2XTDS/electron bunch arrival time (low charge){{/code}} 830 -//always saved (PBD2)// 831 -DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/8FL2XTDS/LOW_CHARGE_ARRIVAL_TIME{{/code}} 832 -DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/8FL2XTDS.LOW_CHARGE_ARRIVAL_TIME{{/code}} 833 -desc: Electron bunch arrival time measured with the BAM after the FLASH2 undulator (pulse resolved data) 834 -units: ps (bigger numbers indicate later arrivaltime of the electrons) 835 - 836 836 **FL1**{{code language="none"}}//Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}} 837 837 //always saved (PBD2)// 838 838 DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}} 839 839 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}} 840 -desc: Electron bunch arrival time measured with the BAM intheaccelerator750 +desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data) 841 841 units: ps (bigger numbers indicate later arrivaltime of the electrons) 842 842 843 -\\ 753 +The BAM measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !). The first values are for FLASH1 bunches. 754 +After a gap of about 70 micros ( 70 colums) with as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start. The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... 844 844 845 -{{info title="BAM hints"}} 846 -* The BAM 4DBC3 measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !). 847 -* The BAM 8FL2XTDS measures only for FLASH2 BUT has the same data structure as the other BAMS ... thus there are also (random) values in in the FLASH1 time slot 848 -** Structure: The first values are for FLASH1 bunches. After a gap of about 70 micros ( 70 colums) with as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start. The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... .In case of doubt ask your local contact 849 -* [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]] 850 -* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] 851 -* a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]] 852 -{{/info}} 756 +Docu for BAM: [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]] 853 853 854 854 855 855 [[Contents>>doc:||anchor="Contents"]] ... ... @@ -1194,6 +1194,10 @@ 1194 1194 1195 1195 [[Contents>>doc:||anchor="Contents"]] 1196 1196 1101 +=== How to read HDF5 with Python via FLASHH5 === 1102 + 1103 +With [[FlashH5>>doc:FLASHUSER.FLASHH5 for easier access of FLASH's HDF5 files]] we provide h5py based examples to access and evaluate FLASH's HDF5 files. 1104 + 1197 1197 \\ 1198 1198 1199 1199 == HDF5 and DOOCS ==