Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -151,14 +151,12 @@ 151 151 152 152 \\ 153 153 154 -==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ==== 154 +==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) / Spectrometer (FLASH1) ==== 155 155 156 -\\ 157 - 158 -(% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation (VME + PhotonFlux ML server)** 159 - 160 160 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 161 -//always saved (PBD)//\\ 157 +//always saved (PBD)// 158 +(% style="color: rgb(165,173,186);" %)New MTCA Version: DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%) 159 +(% style="color: rgb(165,173,186);" %)New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} 162 162 163 163 (% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%) 164 164 (% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%) ... ... @@ -168,6 +168,9 @@ 168 168 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 169 169 //always saved (PBD)// 170 170 169 +(% style="color: rgb(193,199,208);" %)New MTCA Version: DOOCS prop : 170 +{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}} 171 + 171 171 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}} 172 172 DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}} 173 173 desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL ... ... @@ -183,6 +183,9 @@ 183 183 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}} 184 184 //always saved (PBD)// 185 185 187 +(% style="color: rgb(165,173,186);" %)New MTCA Version: DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.BDA/PHOTONFLUX.UJ{{/code}} (%%) 188 +(% style="color: rgb(165,173,186);" %)New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.BDA/PHOTONFLUX.UJ{{/code}} 189 + 186 186 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}} 187 187 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}} 188 188 desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current) ... ... @@ -191,6 +191,8 @@ 191 191 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}} 192 192 //always saved (PBD)// 193 193 198 +(% style="color: rgb(193,199,208);" %)New MTCA Version: DOOCS prop : 199 +{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.BDA/INTENSITY.TD{{/code}}New MTCA Version: DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.BDA/INTENSITY.TD{{/code}}(%%) 194 194 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}} 195 195 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}} 196 196 desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL ... ... @@ -205,55 +205,6 @@ 205 205 206 206 \\ 207 207 208 -(% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation (MTCA, analog to FLASH2 and XFEL)** 209 - 210 -{{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 211 -//always saved (PBD)// 212 -(% style="color: rgb(0,0,0);" %)DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%) 213 -(% style="color: rgb(0,0,0);" %)DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} 214 - 215 -desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator 216 -units : microJ 217 - 218 -\\ 219 - 220 -{{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 221 -//always saved (PBD)// 222 - 223 -(% style="color: rgb(0,0,0);" %)DOOCS prop : 224 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}} 225 - 226 -desc : Energy per pulse measured in the Tunnel. In addition measurement errors and beam position are included for EACH pulse in the pulse train !! (see below) 227 -units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 228 - 229 -{{info title="GMD pulse resolved data structure"}} 230 -For every pulse in the pulse train the information is saved: 231 - 232 - 233 -1. **Intensity per pulse** (a.u. (more or less µJ )) 234 -1. Intensity per pulse (auxillary GMD) - not used 235 -1. Position horizontal (mm, for a single pulse the position information may be very noisy - talk to your local contact) 236 -1. Position vertical (mm, for a single pulse the position information may be very noisy - talk to your local contact) 237 -1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)) 238 -1. Position horizontal sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 239 -1. Position vertical sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 240 -1. Combined warning and error flags 241 - 242 -The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 243 -file 244 - 245 - 246 -[[image:attach:image2021-2-9_10-51-6.png||height="250"]] 247 - 248 -\\ 249 -{{/info}} 250 - 251 -All values for the GMD are also available for the** BDA GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between BDA and Tunnel signal shows the attenuation. **BUT NOTE** that the filter units are downstream the GMD. So if filters are used this influence is NOT measured by the GMD BDA ! 252 - 253 -\\ 254 - 255 -Besides pulse energy the GMD also provides information about the beam position 256 - 257 257 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}} 258 258 //always saved (PBD)// 259 259 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}} ... ... @@ -282,10 +282,6 @@ 282 282 desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical) 283 283 units : mm 284 284 285 -\\ 286 - 287 -==== Spectrometer (FLASH1) ==== 288 - 289 289 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}} 290 290 _always saved (when Spectrum is measured !!) (PBD) _ 291 291 DOOCS prop : {{code language="none"}}TTF2.EXP/PHOTONWL.ML/WAVE_LENGTH/VAL.TD{{/code}} ... ... @@ -684,14 +684,13 @@ 684 684 desc : Energy per pulse measured in the Tunnel (in front of the gas attenuator and the apertures in the Hall) In addition measurement errors and beam position are included for EACH pulse in the pulse train !! (see below) 685 685 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 686 686 687 -{{info title="GMD pulse resolved data structure"}} 688 688 For every pulse in the pulse train the information is saved: 689 689 690 690 691 691 1. **Intensity per pulse** (a.u. (more or less µJ )) 692 692 1. Intensity per pulse (auxillary GMD) - not used 693 -1. Position horizontal (mm, for a single pulse the position inform ation may be very noisy - talk to your local contact)694 -1. Position vertical (mm, for a single pulse the position inform ation may be very noisy - talk to your local contact)645 +1. Position horizontal (mm, for a single pulse the position informytion may be very noisy - talk to your local contact) 646 +1. Position vertical (mm, for a single pulse the position informytion may be very noisy - talk to your local contact) 695 695 1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%)) 696 696 1. Position horizontal sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) 697 697 1. Position vertical sigma (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise) ... ... @@ -703,10 +703,8 @@ 703 703 704 704 [[image:attach:image2021-2-9_10-51-6.png||height="250"]] 705 705 706 -\\ 707 -{{/info}} 708 708 709 - \\659 +{{code language="none"}}{{/code}} 710 710 711 711 All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall ! 712 712