Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -130,10 +130,16 @@ 130 130 DAQ channel: {{code language="none"}}TTF2.FEL/PGFILTERS/PGFILTERS/FW.MOTOR.POS{{/code}} 131 131 desc: Position of the PG filter wheel 3 132 132 units: degree 133 + 133 133 \\ 134 134 136 + 137 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact 138 + 135 135 [[Contents>>doc:||anchor="Contents"]] 136 136 141 +\\ 142 + 137 137 ==== Photon Diagnostics SASE / Spectrometer (FLASH1) ==== 138 138 139 139 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} ... ... @@ -291,7 +291,7 @@ 291 291 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}} 292 292 desc: Electron bunch arrival time measured with the BAM (more or less) before the undulator (pulse resolved data) 293 293 units: ps (bigger numbers indicate later arrivaltime of the electrons) 294 -note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http:// mskwiki/index.php?title=BAM-DAQ_Channels||shape="rect"]]300 +note: besides the arivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved. [[LINK to detailled infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] and to a recent [[talk about the working principle of the BAM>>url:https://confluence.desy.de/download/attachments/134216957/BAM-basics_and_outlook-2018_DESY-template_16-9Format.pdf?version=1&modificationDate=1565162143328&api=v2||shape="rect"]] 295 295 296 296 ===== electron beam profile ===== 297 297 ... ... @@ -515,14 +515,159 @@ 515 515 516 516 === FLASH2 === 517 517 524 +There is analog to FLASH1 a permanently running "PhotonDagnostic DAQ FLASH2" (PBD2) and 2 User DAQs 525 + 526 +==== Beamline info (FLASH2) ==== 527 + 528 +(% style="color: rgb(255,153,0);" %)(not yet available){{code language="none"}}/FL2/Beamlines/Attenuator/pressure {{/code}}(%%) 529 +//always saved (PBD2)// 530 +DOOCS prop : {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} 531 +DAQ channel: {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} 532 +desc: set pressure in the gas attenuator 533 +units: mbar 518 518 \\ 519 519 536 +{{code language="none"}}/FL2/Beamlines/FL20/Shutter/open{{/code}} 537 +//always saved (PBD2)// 538 +DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.SIS.FL2FS/FL20.SHUTTER/CH00.TD{{/code}} 539 +DAQ channel: {{code language="none"}}FLASH.FEL/ADC.SIS.FL2FS/FL20.SHUTTER{{/code}} 540 +desc: BL Beamline Fast shutter state: 1 is open, 0 is closed ( for technical reasons there are 100 vales of this state saved ...) 541 +units: none 542 + 543 + 544 +{{code language="none"}}/FL2/Beamlines/Filter wheel/position wheel 1{{/code}} 545 +//always saved (PBD2)// 546 +DOOCS prop : {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS{{/code}} 547 +DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS 548 +desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASH.Filter history (BL filterwheel 12)]] 549 +units: degree 520 520 \\ 521 521 552 + 553 +//always saved (PBD2)// 554 +\\\\[[here>>doc:FLASH.Filter history (BL filterwheel 12)]] 555 +{{code language="none"}}/FL2/Beamlines/Filter wheel/position wheel 2 DOOCS prop : FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS desc: Position of the BL filter wheel 2 - to correlate with the filter material please look units: degree{{/code}} 556 + 522 522 \\ 523 523 559 +NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact 560 + 561 +[[Contents>>doc:||anchor="Contents"]] 562 + 524 524 \\ 525 525 565 +\\ 566 + 567 +==== Photon Diagnostics SASE (XGMD) ==== 568 + 569 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 570 +//always saved (PBD2)// 571 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}} 572 +DAQ channel:{{code language="none"}} FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}} 573 +desc : calibrated average ( ~~ 20 sec averaging time ) SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current) 574 +units : microJ 575 + 576 +\\ 577 + 578 +(% style="color: rgb(255,204,0);" %)average Sigma to be included in 579 + 580 +(% style="color: rgb(193,199,208);" %){{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel uncertainty{{/code}} (%%) 581 +(% style="color: rgb(193,199,208);" %)//always saved (PBD2)// (%%) 582 +(% style="color: rgb(193,199,208);" %)DOOCS prop : FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%) 583 +(% style="color: rgb(193,199,208);" %)DAQ channel: FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ.SIGMA (%%) 584 +(% style="color: rgb(193,199,208);" %)desc : This parameter gives an indication of the error of the measurement of the average pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%) 585 +(% style="color: rgb(193,199,208);" %)units : microJ 586 + 587 +\\ 588 + 589 +\\ 590 + 591 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 592 +//always saved (PBD2)// 593 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}} 594 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}} 595 +desc : Energy per pulse measured in the Tunnel (in fromt of the gas attenuator and the apertures in the Hall) 596 +units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) [[see here for help>>doc:FLASH.Calibrating the pulse resolved (electron) data from GMD]] 597 + 598 +\\ 599 + 600 +\\ 601 + 602 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel uncertainty (sigma){{/code}} 603 +//always saved (PBD2)// 604 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.SIGMA.TD{{/code}} 605 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL:4{{/code}} 606 +desc :(% style="color: rgb(0,0,0);" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise, detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%) 607 +units : a.u. (more or less µJ - related to the value of the pulse energy ) 608 + 609 + 610 +{{code language="none"}}{{/code}} 611 + 612 +All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall ! 613 + 614 +\\ 615 + 616 +Besides pulse energy the GMD also provides information about the beam position 617 + 618 +\\ 619 + 620 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel horizontal{{/code}} 621 +//always saved (PBD2)// 622 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}} 623 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}} 624 +desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (tunnel, x=horizontal) 625 +units : mm 626 + 627 +\\ 628 + 629 +\\ 630 + 631 +\\ 632 + 633 +{{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel vertical{{/code}} 634 +//always saved (PBD2)// 635 +DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}} 636 +DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}} 637 +desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the [[GMD>>doc:FLASH.Gas Monitor Detector]] (tunnel, x=horizontal) 638 +units : mm 639 + 640 +\\ 641 + 642 +\\ 643 + 644 + 645 +//always saved (PBD2)// 646 +\\\\{{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel x DOOCS prop : FLASH.FEL/XGM.BPM/FL2.HALL/X.TDDAQ channel: FLASH.FEL/XGM.BPM/FL2.HALL:2 desc: {{/code}}Besides the well calibrated averaged beam position information there is also the option 647 +{{code language="none"}}to measure the beam position on a single bunch level. HOWEVER this methide needs a perfectly adjusted signal level (talk to your local contact !!) and also then the signal to noise is rather small and one needs some averaging ... BUT with this option one can determine if there was a spatial slope on a burst (say forst bunches were lower than the last ones or so ...)units : mm {{/code}} 648 + 649 +{{code language="none"}}(x=horizontal, y = vertial){{/code}} 650 + 651 +again the same parameter set is available for the **HALL GMD** 652 + 653 +\\ 654 + 655 +\\ 656 + 657 +\\ 658 + 659 +\\ 660 + 661 +\\ 662 + 663 +\\ 664 + 665 +\\ 666 + 667 +\\ 668 + 669 +\\ 670 + 671 +\\ 672 + 673 +\\ 674 + 675 +\\ 676 + 526 526 (% class="wrapped" %) 527 527 |=((( 528 528 DAQ name