Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 53.1
edited by cpassow
on 2021/10/14 15:53
Change comment: There is no comment for this version
To version 56.1
edited by sndueste
on 2022/09/07 09:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.cpassow
1 +XWiki.sndueste
Content
... ... @@ -206,8 +206,7 @@
206 206  
207 207  ==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ====
208 208  
209 -\\
210 -
209 +{{expand title="Discontinued GMD format (used until 2021)"}}
211 211  (% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation  (VME + PhotonFlux ML server)**
212 212  
213 213  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
... ... @@ -255,10 +255,11 @@
255 255  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}}
256 256  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
257 257  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
257 +{{/expand}}
258 258  
259 259  \\
260 260  
261 -(% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation  (MTCA, analog to FLASH2 and XFEL)**
261 +(% style="letter-spacing: 0px; color: rgb(0, 0, 0)" %)**NEW (since 2021) GMD data recording / evaluation  (same format as FLASH2 and XFEL)**
262 262  
263 263  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
264 264  //always saved (PBD)//
... ... @@ -435,7 +435,7 @@
435 435  {{info title="BAM hints"}}
436 436  * besides the arrivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved.In case of doubt ask your local contact
437 437  * [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
438 -* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
438 +* [[LINK to detailed infos from MSK>>url:https://confluence.desy.de/display/SDiagPublic/BAM+Data+Structure||shape="rect"]]
439 439  * a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
440 440  {{/info}}
441 441