Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 54.1
edited by sndueste
on 2022/01/14 09:44
Change comment: There is no comment for this version
To version 52.1
edited by sndueste
on 2021/04/15 12:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -103,12 +103,12 @@
103 103  
104 104  {{layout-section ac:type="single"}}
105 105  {{layout-cell}}
106 -{{info}}
107 -=== Reference implementation (Python) ===
106 +{{info title="Sample scripts in python"}}
107 +=== Sample scripts / Reference implementation (Python) ===
108 108  
109 -(imperative)  (% class="Object" %)[[https:~~/~~/gitlab.desy.de/christopher.passow/flash-daq-hdf>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]]
109 +[[~[~[image:attach:binder_badge.png~|~|thumbnail="true" width="120"~]~]>>url:https://mybinder.org/v2/git/https%3A%2F%2Fgitlab.desy.de%2Fchristopher.passow%2Fflash-daq-hdf/master||shape="rect"]]
110 110  
111 -(% class="Object" %)(object oriented) [[https:~~/~~/gitlab.desy.de/christopher.passow/fdh-builder>>url:https://gitlab.desy.de/christopher.passow/fdh-builder.git||shape="rect"]]
111 +(% class="Object" %)[[https:~~/~~/gitlab.desy.de/christopher.passow/flash-daq-hdf>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]]
112 112  {{/info}}
113 113  {{/layout-cell}}
114 114  {{/layout-section}}
... ... @@ -208,7 +208,6 @@
208 208  
209 209  \\
210 210  
211 -{{expand title="GMD format untill 2021"}}
212 212  (% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation  (VME + PhotonFlux ML server)**
213 213  
214 214  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
... ... @@ -256,12 +256,9 @@
256 256  DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}}
257 257  desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
258 258  units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
259 -{{/expand}}
260 260  
261 261  \\
262 262  
263 -\\
264 -
265 265  (% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation  (MTCA, analog to FLASH2 and XFEL)**
266 266  