Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/02/06 10:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,12 +103,12 @@ 103 103 104 104 {{layout-section ac:type="single"}} 105 105 {{layout-cell}} 106 -{{info}} 107 -=== Reference implementation (Python) === 106 +{{info title="Sample scripts in python"}} 107 +=== Sample scripts / Reference implementation (Python) === 108 108 109 - (imperative) (% class="Object" %)[[https:~~/~~/gitlab.desy.de/christopher.passow/flash-daq-hdf>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]]109 +[[~[~[image:attach:binder_badge.png~|~|thumbnail="true" width="120"~]~]>>url:https://mybinder.org/v2/git/https%3A%2F%2Fgitlab.desy.de%2Fchristopher.passow%2Fflash-daq-hdf/master||shape="rect"]] 110 110 111 -(% class="Object" %) (object oriented)[[https:~~/~~/gitlab.desy.de/christopher.passow/fdh-builder>>url:https://gitlab.desy.de/christopher.passow/fdh-builder.git||shape="rect"]]111 +(% class="Object" %)[[https:~~/~~/gitlab.desy.de/christopher.passow/flash-daq-hdf>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]] 112 112 {{/info}} 113 113 {{/layout-cell}} 114 114 {{/layout-section}} ... ... @@ -206,7 +206,8 @@ 206 206 207 207 ==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ==== 208 208 209 -{{expand title="Discontinued GMD format (used until 2021)"}} 209 +\\ 210 + 210 210 (% style="color: rgb(0,0,0);" %)**Discontinued GMD data recording / evaluation (VME + PhotonFlux ML server)** 211 211 212 212 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} ... ... @@ -254,11 +254,10 @@ 254 254 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}} 255 255 desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise 256 256 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** 257 -{{/expand}} 258 258 259 259 \\ 260 260 261 -(% style=" letter-spacing: 0px; color: rgb(0,since2021) GMD data recording / evaluation (sameformatasFLASH2 and XFEL)**261 +(% style="color: rgb(0,0,0);" %)**NEW (2021) GMD data recording / evaluation (MTCA, analog to FLASH2 and XFEL)** 262 262 263 263 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 264 264 //always saved (PBD)// ... ... @@ -435,7 +435,7 @@ 435 435 {{info title="BAM hints"}} 436 436 * besides the arrivaltime from FLASH1 there is also the FLASH2/3 electron arrival time saved.In case of doubt ask your local contact 437 437 * [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]] 438 -* [[LINK to detailed infos from MSK >>url:https://confluence.desy.de/display/SDiagPublic/BAM+Data+Structure||shape="rect"]]438 +* [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]] 439 439 * a recent [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]] 440 440 {{/info}} 441 441