Changes for page The FLASH HDF5 structure

Last modified by sndueste on 2025/02/06 10:55

From version 9.1
edited by sndueste
on 2019/09/17 16:31
Change comment: There is no comment for this version
To version 11.1
edited by sndueste
on 2019/09/17 16:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -140,7 +140,7 @@
140 140  
141 141  \\
142 142  
143 -==== Photon Diagnostics SASE / Spectrometer (FLASH1) ====
143 +==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) / Spectrometer (FLASH1) ====
144 144  
145 145  {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
146 146  //always saved (PBD)//
... ... @@ -564,7 +564,7 @@
564 564  
565 565  \\
566 566  
567 -==== Photon Diagnostics SASE (XGMD) ====
567 +==== Photon Diagnostics SASE ([[XGMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]] - FLASH2) ====
568 568  
569 569  {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
570 570  //always saved (PBD2)//
... ... @@ -626,10 +626,6 @@
626 626  
627 627  \\
628 628  
629 -\\
630 -
631 -\\
632 -
633 633  {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel vertical{{/code}}
634 634  //always saved (PBD2)//
635 635  DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}}
... ... @@ -654,14 +654,43 @@
654 654  
655 655  \\
656 656  
653 +==== Photon Diagnostics OPIS[[ >>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]](FLASH2) ====
654 +
655 +for more info see: [[ OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]
656 +
657 +(The OPIS hall is not installed yet ...)
658 +
657 657  \\
658 658  
661 +{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean photon energy{{/code}}
662 +// saved opon request (PBD2)//
663 +DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}}
664 +DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}}
665 +desc : mean photon energy ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy)
666 +units : eV
667 +
659 659  \\
660 660  
670 +{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean wavelength{{/code}}
671 +// saved opon request (PBD2)//
672 +DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}}
673 +DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}}
674 +desc : meanwavelength ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy)
675 +units : nm
676 +
661 661  \\
662 662  
679 +{{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/number of analyzed bunch        (in older version this can be found in OPIS tunnel/Expert stuff/General operation parameters/){{/code}}
680 +// saved opon request (PBD2)//
681 +DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}}
682 +DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}}
683 +desc : The bunch number of the bunch used for the wavelength calculation
684 +units :
685 +
663 663  \\
664 664  
688 +If Opis is running typically on the the averaged data is saved. For several experiments it may make sense to save the information for each single bunch. This is up to now done by savng the compleate ADC trace of the TOF setup. This is a huge amount of data and needs processing. This has to be performed after the beamtime in close contact to [[Markus Braune>>mailto:markus.braune@desy.de||shape="rect"]] ( respobsible for [[OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]])
689 +
665 665  \\
666 666  
667 667  \\
... ... @@ -674,6 +674,8 @@
674 674  
675 675  \\
676 676  
702 +\\
703 +
677 677  (% class="wrapped" %)
678 678  |=(((
679 679  DAQ name