Wiki source code of The FLASH HDF5 structure

Version 82.1 by sndueste on 2024/05/17 10:13

Hide last authors
cpassow 44.1 1 {{layout}}
2 {{layout-section ac:type="single"}}
3 {{layout-cell}}
sendels 1.1 4 == Contents ==
5
6
7
sndueste 13.1 8 {{toc/}}
sendels 1.1 9
10
11 == General information about HDF5 ==
12
sndueste 79.1 13 HDF5 is a data format maintained by the HDF group. For detailed general information see [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|height="12" width="13"~]~]>>url:https://portal.hdfgroup.org/display/support||shape="rect"]]
sendels 1.1 14
sndueste 79.1 15 To download the HDF5 Viewer click [[here~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|height="12" width="13"~]~]>>url:https://portal.hdfgroup.org/display/support/Download+HDFView||shape="rect"]]
sendels 1.1 16
sndueste 79.1 17 For use on the DESY Maxwell or PAL (max-fsc or pal) **hdfview** is available in the xray module :
18 {{code language="none"}}> module load xray{{/code}}
sendels 1.1 19 {{code language="none"}}> hdfview{{/code}}
20
sndueste 49.1 21 or you can use
22
sndueste 79.1 23 {{code language="none"}}
24 > silx view
25 {{/code}}
sndueste 49.1 26
27
sendels 4.1 28 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 29
sndueste 45.1 30 == The FLASH HDF5 format ==
sendels 1.1 31
sndueste 45.1 32 FLASH provides a conversion of its data acquisition (DAQ) to the commonly used [[HDF5>>url:https://www.hdfgroup.org/solutions/hdf5/||shape="rect"]] format. Correlated  data are mapped by a primary index called **train ID**. Every data set has an individual index of train IDs to identify the data even when data are missing or deviate in update rate. If the data set of choice contains gaps,  users have to decide how to treat missing values. DAQ channels are spread across various files with one file name pattern for each DAQ. This means users have to assemble data from different files if necessary.
sndueste 40.1 33
34 The hierarchy is realized using a human readable named HDF tree with each DAQ channel containing the data sets "//value//" and "//index//". Additionally, the HDF group //zraw// contains a tree of the original DAQ channel names.
35
36 Reference implementation, which follows the concept of Python libraries like Pandas, Xarray, or Dask, is given below.
37
38 {{expand title="Discontinued HDF formats"}}
sndueste 47.1 39 === Comparison to FLASH's deprecated HDF formats ===
sndueste 40.1 40
41 Before 2021, FLASH provided two different HDF formats formally known as //near-online// and //offline// HDF files.
42
43 All data sets were aligned by the same global index by filling in missing data. Fast DAQ channels  (pulse synchronous data - update 10 Hz) are filled in by NaN or 0, slow channels (not pulse synchronous data - update e.g. 1 Hz ) are interpolated by the DAQs libraries, by keeping the value constant up to the next change.
44
45 While the near-online HDF files were converted live during the beamtime, the offline HDF files were manually compiled weeks/months later. Near-online HDF files were used by a provided API [[BeamtimeDaqAccess>>url:https://confluence.desy.de/display/FLASHUSER/Near-Online+data+analysis#Near-Onlinedataanalysis-BriefUserGuidetoBeamtimeDAQAccess||shape="rect"]], which also searches for DAQ channels in files. With assembled files "by run", all DAQ channels were existing in the same HDF file. While shorter runs usually fitted into one file, longer runs still had to be aggregated over several files. The creation of the assembled type of files still involves the use of fairly unstable DAQ Mex-functions As the environment required for using the Mex-functions is already deprecated, its continued existence is uncertain.
46
47 The HDF hierarchy is almost identical in all formats. While in the the recent format each DAQ channel contains the data sets "value" and "index", the deprecated format had one data set for each DAQ channel. The deprecated formats supplies no time axis parameters for spectra data types.
sndueste 45.1 48
49
sndueste 46.1 50 **HDF5 example files (old format)**
sndueste 45.1 51
52 Here we have a few HDF5 samples (User data combined with Photon diagnostics data) from a few beamtimes showing the different kind options.
53
54 [[image:attach:image2019-10-21_17-2-50.png||thumbnail="true" width="300"]] [[download HDF5 (Images @ FL2)>>url:https://desycloud.desy.de/index.php/s/nyEgeCWJFC4gao2||shape="rect"]]
55
56
57 [[~[~[image:attach:image2019-10-22_10-52-27.png~|~|thumbnail="true" width="300"~]~]download HDF5 (GHz ADC and OPIS @ FL2)>>url:https://desycloud.desy.de/index.php/s/AeA2kPNNnZgX95A||shape="rect"]]
58
59
sndueste 79.1 60
sndueste 40.1 61 {{/expand}}
62
sndueste 45.1 63 === HDF examples: ===
cpassow 44.1 64 {{/layout-cell}}
65 {{/layout-section}}
sndueste 40.1 66
cpassow 44.1 67 {{layout-section ac:type="three_equal"}}
68 {{layout-cell}}
sndueste 79.1 69 * ADC data as example for **fast** **data** (10 Hz):            
sndueste 40.1 70
cpassow 44.1 71 [[image:attach:image2020-11-16_15-26-28.png||height="250"]]
72 {{/layout-cell}}
73
74 {{layout-cell}}
sndueste 71.1 75 * The //average// FEL pulse energy as example for the **slow** **data**. Here the data is not saved with 10 Hz  - thus not for every FEL pulse train.  The data is typically saved with 1 Hz if the values are changing (like the FEL energy) and every about 20 sec if there is no change for longer time ( e.g. motor set values). Thus to use the data together with the "fast" one, one has to interpolate the data as explained in the examples in the repos below show (e.g. {{code language="none"}}df['GMD_T_average'] = df['GMD_T_average'].interpolate(method='linear'){{/code}})
cpassow 44.1 76
sndueste 70.1 77 ( as example only every 10th train ID is listed in the HDF group "index")
sndueste 40.1 78
cpassow 44.1 79 [[image:attach:image2020-11-16_15-31-45.png||height="250"]]
80 {{/layout-cell}}
81
82 {{layout-cell}}
sndueste 41.1 83 * (((
cpassow 44.1 84 //zraw// group contains the **original DAQ (DOOCS) names**
sndueste 41.1 85 )))
sndueste 40.1 86
sndueste 41.1 87 of the properties saved in the DESY internal raw format. (For experts)
sndueste 40.1 88
89
cpassow 44.1 90 [[image:attach:image2020-11-16_16-26-3.png||height="400"]]
91 {{/layout-cell}}
92 {{/layout-section}}
sndueste 41.1 93
cpassow 44.1 94 {{layout-section ac:type="single"}}
95 {{layout-cell}}
cpassow 53.1 96 {{info}}
sndueste 79.1 97 === There are different options that help you to work with the FLASH HDF5 data in Python ===
sndueste 40.1 98
sndueste 78.1 99 * The currently developed option for large data sets: [[the FAB package>>url:https://hasfcpkg.desy.de/fab/fab.html||shape="rect"]] ... see below
100 * and for smaller projects:  (% class="Object" %)[[https:~~/~~/gitlab.desy.de/christopher.passow/flash-daq-hdf>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]]
sndueste 40.1 101
sndueste 78.1 102 (% class="Object" %)See also the collection of Demo data and sample scripts : [[doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).Collection of HDF5 sample data from different beamlines.WebHome]] and [[doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).DEMO - Working with FLASH data.WebHome]]
sndueste 40.1 103 {{/info}}
cpassow 44.1 104 {{/layout-cell}}
105 {{/layout-section}}
sndueste 40.1 106
cpassow 44.1 107 {{layout-section ac:type="single"}}
108 {{layout-cell}}
sndueste 63.1 109
110
sndueste 45.1 111 == Complete list of recordable parameters ==
sndueste 40.1 112
sndueste 79.1 113 The complete list for the relation between DOOCS names and HDF5 names for the recordable parameters can be found in [[DESY's Repository~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|height="12" width="13"~]~]>>url:https://stash.desy.de/projects/CS/repos/pah/browse/src/camp/data/channel2HdfName.dat||shape="rect"]].
114
sendels 1.1 115
sndueste 79.1 116 == Most popular FLASH parameters and their names in HDF5, DOOCS and (raw) DAQ ==
sendels 1.1 117
erkben 30.1 118 {{id name="DOOCSparameters"/}}
119
sndueste 5.1 120 Note, the HDF group and data set names apply to our HDF tree version since vers. 0.3.0.
sendels 1.1 121
122
123 === FLASH1 ===
124
125 ==== Beamline info (FLASH1) ====
126
sndueste 79.1 127 {{code language="none"}}/FL1/Beamlines/Attenuator/pressure{{/code}}
128 //always saved (PBD)//
129 DOOCS prop : {{code language="none"}}FLASH.FEL/GAS_DOSING/FL1.ATTENUATOR/PRESSURE{{/code}}
130 DAQ channel: {{code language="none"}}FLASH.FEL/GAS_DOSING/FL1.ATTENUATOR/PRESSURE{{/code}}
131 desc: set pressure in the gas attenuator
sendels 1.1 132 units: mbar
sndueste 79.1 133
sendels 1.1 134
sndueste 79.1 135 {{code language="none"}}/FL1/Beamlines/BL/Fast shutter/open{{/code}}
136 //always saved (PBD)//
137 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.SIS.FL1FS/BL.SHUTTER/CH00.TD{{/code}}
138 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.SIS.FL1FS/BL.SHUTTER{{/code}}
139 desc: BL Beamline Fast shutter state: 1 is open, 0 is closed ( for technical reasons there are 100 vales of this state saved ...)
sendels 1.1 140 units: none
141
sndueste 79.1 142 {{code language="none"}}/FL1/Beamlines/PG/Fast shutter/open{{/code}}
143 //always saved (PBD)//
144 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.SIS.FL1FS/PG.SHUTTER/CH00.TD{{/code}}
145 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.SIS.FL1FS/PG.SHUTTER{{/code}}
146 desc: PG Beamline Fast shutter state: 1 is open, 0 is closed ( for technical reasons there are 100 vales of this state saved ...)
sendels 1.1 147 units: none
148
sndueste 79.1 149 {{code language="none"}}/FL1/Beamlines/BL/Filters/BL filter wheel/position filter 1{{/code}}
150 //always saved (PBD)//
151 DOOCS prop : {{code language="none"}}TTF2.FEL/BLFILTERS1/FILTER1/FW.MOTOR.POS{{/code}}
152 DAQ channel: {{code language="none"}}TTF2.FEL/BLFILTERS1/FILTER1/FW.MOTOR.POS{{/code}}
sndueste 24.1 153 desc: Position of the BL filter wheel 1 - to correlate with the filter material please look [[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filter wheels in FLASH1 and FLASH2.WebHome]]
sendels 1.1 154 units: degree
sndueste 79.1 155
sendels 1.1 156
sndueste 79.1 157 {{code language="none"}}/FL1/Beamlines/BL/Filters/BL filter wheel/position filter 2{{/code}}
158 //always saved (PBD)//
159 DOOCS prop : {{code language="none"}}TTF2.FEL/BLFILTERS2/FILTER2/FW.MOTOR.POS{{/code}}
160 DAQ channel: {{code language="none"}}TTF2.FEL/BLFILTERS2/FILTER2/FW.MOTOR.POS{{/code}}
sndueste 24.1 161 desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filter wheels in FLASH1 and FLASH2.WebHome]]
sendels 1.1 162 units: degree
sndueste 79.1 163
sendels 1.1 164
sndueste 79.1 165 {{code language="none"}}/FL1/Beamlines/PG/Filters/position filter 1{{/code}}
166 //always saved (PBD)//
167 DOOCS prop : = TTF2.FEL/BDAF1/BDA.F1/FW.MOTOR.POS=
168 DAQ channel: {{code language="none"}}TTF2.FEL/BDAF1/BDA.F1/FW.MOTOR.POS{{/code}}
169 desc: Position of the PG filter wheel 1
sendels 1.1 170 units: degree
sndueste 79.1 171
sendels 1.1 172
sndueste 79.1 173 {{code language="none"}}/FL1/Beamlines/PG/Filters/position filter 2{{/code}}
174 //always saved (PBD)//
175 DOOCS prop : {{code language="none"}}TTF2.FEL/BDAF2/BDA.F2/FW.MOTOR.POS{{/code}}
176 DAQ channel: {{code language="none"}}TTF2.FEL/BDAF2/BDA.F2/FW.MOTOR.POS{{/code}}
177 desc: Position of the PG filter wheel 2
sendels 1.1 178 units: degree
sndueste 79.1 179
sendels 1.1 180
sndueste 79.1 181 {{code language="none"}}/FL1/Beamlines/PG/Filters/position filter 3{{/code}}
182 //always saved (PBD)//
183 DOOCS prop : {{code language="none"}}TTF2.FEL/PGFILTERS/PGFILTERS/FW.MOTOR.POS{{/code}}
184 DAQ channel: {{code language="none"}}TTF2.FEL/PGFILTERS/PGFILTERS/FW.MOTOR.POS{{/code}}
185 desc: Position of the PG filter wheel 3
sendels 1.1 186 units: degree
sndueste 8.1 187
sendels 1.1 188
sndueste 8.1 189
sndueste 34.1 190 NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. For more Info contact your local contact
sndueste 8.1 191
sendels 4.1 192 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 193
sndueste 8.1 194
sndueste 39.1 195 ==== Photon Diagnostics SASE ([[GMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]]) ====
sendels 1.1 196
sndueste 55.1 197 {{expand title="Discontinued GMD format (used until 2021)"}}
sndueste 79.1 198 (% style="color:#000000" %)**Discontinued GMD data recording / evaluation  (VME + PhotonFlux ML server)**
sndueste 39.1 199
sndueste 79.1 200 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
sndueste 40.1 201 //always saved (PBD)//
sndueste 34.1 202
sndueste 79.1 203 (% style="color:#000000" %)DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT04/VAL{{/code}} (%%)
204 (% style="color:#000000" %)DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENPULSEIC{{/code}}(%%)
205 desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator (ion current)
sendels 1.1 206 units : microJ
207
sndueste 79.1 208 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
sndueste 34.1 209 //always saved (PBD)//
210
sndueste 79.1 211 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT34/VAL{{/code}}
212 DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.USER{{/code}}
sendels 1.1 213 desc :Energy per pulse Tunnel (from e-) - the values are set to "0" if there was no SASE beam in the FEL
sndueste 23.1 214 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
sendels 1.1 215
sndueste 79.1 216 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel (raw){{/code}}
217 //always saved (PBD)//
218 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT14/VAL{{/code}}
219 DAQ channel: {{code language="none"}}PBD.PHFLUX/TUNNEL.ENERGYPULSE.FF{{/code}}
220 desc :Energy per pulse Tunnel (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
sndueste 23.1 221 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
sendels 1.1 222
sndueste 79.1 223 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy BDA{{/code}}
sndueste 34.1 224 //always saved (PBD)//
225
sndueste 79.1 226 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT05/VAL{{/code}}
227 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENPULSEIC{{/code}}
sendels 1.1 228 desc : calibrated average SASE Energy/pulse measured in the BDA (in the experimental hall) after the attenuator (ion current)
229 units : microJ
230
sndueste 79.1 231 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA{{/code}}
sndueste 34.1 232 //always saved (PBD)//
233
sndueste 79.1 234 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT35/VAL{{/code}}
235 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.USER{{/code}}
sendels 1.1 236 desc :Energy per pulse BDA (from e-) - the values are set to "0" if there was no SASE beam in the FEL
sndueste 23.1 237 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision) **[[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
sendels 1.1 238
sndueste 79.1 239 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy BDA (raw){{/code}}
240 //always saved (PBD)//
241 DOOCS prop : {{code language="none"}}TTF2.DAQ/PHFLUX/OUT15/VAL{{/code}}
242 DAQ channel: {{code language="none"}}PBD.PHFLUX/BDA.ENERGYPULSE.FF{{/code}}
243 desc :Energy per pulse BDA (from e-) - uncorrected values. There are also values saved if there was no beam ... just background noise
sndueste 23.1 244 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
sndueste 54.1 245 {{/expand}}
sendels 1.1 246
sndueste 34.1 247
sndueste 79.1 248 (% style="color:#000000; letter-spacing:0px" %)**NEW (since 2021) GMD data recording / evaluation  (same format as FLASH2 and XFEL)**
sndueste 54.1 249
sndueste 79.1 250 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
251 //always saved (PBD)//
252 (% style="color:#000000" %)DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%)
253 (% style="color:#000000" %)DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}}
sndueste 39.1 254
sndueste 79.1 255 desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator
sndueste 39.1 256 units : microJ
257
258
sndueste 79.1 259 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
sndueste 39.1 260 //always saved (PBD)//
261
sndueste 79.1 262 (% style="color:#000000" %)DOOCS prop : 
sndueste 39.1 263 {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}
264
265 desc : Energy per pulse measured in the Tunnel.  In addition measurement errors and beam position are included for EACH pulse in the pulse train  !! (see below)
266 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
267
268 {{info title="GMD pulse resolved data structure"}}
sndueste 79.1 269 For every pulse in the pulse train the information is saved:
sndueste 39.1 270
271
272 1. **Intensity per pulse** (a.u. (more or less µJ ))
273 1. Intensity per pulse (auxillary GMD) - not used
274 1. Position horizontal (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
275 1. Position vertical (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
sndueste 79.1 276 1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color:#000000" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%))
sndueste 39.1 277 1. Position horizontal sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
278 1. Position vertical sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
279 1. Combined warning and error flags
280
281 The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 
282 file
283
284
285 [[image:attach:image2021-2-9_10-51-6.png||height="250"]]
286
sndueste 79.1 287
sndueste 39.1 288 {{/info}}
289
sndueste 79.1 290 All values for the GMD are also available for the** BDA GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between BDA and Tunnel signal shows the attenuation. **BUT NOTE** that the filter units  are downstream the GMD. So if filters  are used this influence is NOT measured by the GMD BDA !
sndueste 39.1 291
292
293 Besides  pulse energy the GMD also provides information about the beam position
294
sndueste 79.1 295 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal{{/code}}
296 //always saved (PBD)//
297 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
298 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IX.POS{{/code}}
299 desc :Beam position of the photon Beam determined by the GMD (BDA, x=horizontal)
sendels 1.1 300 units : mm
301
sndueste 79.1 302 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position BDA vertical{{/code}}
303 //always saved (PBD)//
304 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}}
305 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.BDA/IY.POS{{/code}}
306 desc :Beam position of the photon Beam determined by the GMD (BDA, y=vertical)
sendels 1.1 307 units : mm
308
sndueste 79.1 309 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel horizontal{{/code}}
310 //always saved (PBD)//
311 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}}
312 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IX.POS{{/code}}
313 desc :Beam position of the photon Beam determined by the GMD (TUNNEL, x=horizontal)
sendels 1.1 314 units : mm
315
sndueste 79.1 316 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Beam position/position tunnel vertical{{/code}}
317 //always saved (PBD)//
318 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}}
319 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL1.TUNNEL/IY.POS{{/code}}
320 desc :Beam position of the photon Beam determined by the GMD (TUNNEL, y=vertical)
sendels 1.1 321 units : mm
322
sndueste 39.1 323
324 ==== Spectrometer (FLASH1) ====
325
sndueste 79.1 326 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength{{/code}}
327 _always saved (when Spectrum is measured !!) (PBD) _
328 DOOCS prop : {{code language="none"}}TTF2.EXP/PHOTONWL.ML/WAVE_LENGTH/VAL.TD{{/code}}
329 DAQ channel: {{code language="none"}}PBD.PHOTONWL.ML/WAVE_LENGTH{{/code}}
330 desc : XUV Spectrum measured with the "tunnel spectrometer"
sendels 1.1 331 units :
332
sndueste 79.1 333 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength start value{{/code}}
334 _always saved (when Spectrum is measured !!) (PBD) _
335 DOOCS prop : {{code language="none"}}TTF2.EXP/PBD.PHOTONWL.ML/BSTART/VAL{{/code}}
336 DAQ channel: {{code language="none"}}TTF2.EXP/PBD.PHOTONWL.ML/BSTART/VAL{{/code}}
337 desc : start value (in nm) for the wavelength axis of the XUV Spectrum measured with the "tunnel spectrometer"
sendels 1.1 338 units : nm
339
sndueste 79.1 340 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/Tunnelspectrometer/wavelength increment{{/code}}
341 _always saved (when Spectrum is measured !!) (PBD) _
342 DOOCS prop : ==
343 DAQ channel: ==
344 desc : increment value (in nm) for each pixel for the wavelength axis of the XUV Spectrum measured with the "tunnel spectrometer"
sendels 1.1 345 units : nm
346
sndueste 79.1 347 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/PG2 spectrometer/photon energy{{/code}}
348 //saved on DEMAND (PBD spectrometer stream)//
349 DOOCS prop : ==
350 DAQ channel: {{code language="none"}}PBD.PHOTONEN.ML/PHOTON_ENERGY{{/code}}
sendels 1.1 351 desc : XUV Spectrum in eV measured with the "PG2 spectrometer"
352 units :
353
sndueste 79.1 354 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/PG2 spectrometer/photon energy start value{{/code}}
355 //saved on DEMAND (PBD spectrometer stream)//
356 DOOCS prop : ==
357 DAQ channel: ==
358 desc : start value (in eV) for the wavelength axis of the XUV Spectrum measured with the "PG2 spectrometer"
sendels 1.1 359 units : eV
360
sndueste 79.1 361 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/PG2 spectrometer/photon energy increment{{/code}}
362 //saved on DEMAND (PBD spectrometer stream)//
363 DOOCS prop : ==
364 DAQ channel: ==
365 desc : increment value (in eV) for each pixel for the wavelength axis of the XUV Spectrum measured with the "PG spectrometer"
sendels 1.1 366 units : eV
367
sndueste 79.1 368 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/PG2 spectrometer/photon wavelength{{/code}}
369 //saved on DEMAND (PBD spectrometer stream)//
370 DOOCS prop : ==
371 DAQ channel: {{code language="none"}}PHOTONEN.ML/PHOTON_WAVE_LEN{{/code}}
sendels 1.1 372 desc : XUV Spectrum in nm measured with the "PG2 spectrometer"
373 units :
374
sndueste 79.1 375 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/PG2 spectrometer/photon wavelength increment{{/code}}
376 //saved on DEMAND (PBD spectrometer stream)//
377 DOOCS prop : ==
378 DAQ channel: ==
379 desc : start value (in nm) for the wavelength axis of the XUV Spectrum measured with the "PG2 spectrometer"
sendels 1.1 380 units : nm
381
sndueste 79.1 382 {{code language="none"}}/FL1/Photon Diagnostic/Wavelength/PG2 spectrometer/photon wavelength start value{{/code}}
383 //saved on DEMAND (PBD spectrometer stream)//
384 DOOCS prop : ==
385 DAQ channel: ==
386 desc : increment value (in nm) for each pixel for the wavelength axis of the XUV Spectrum measured with the "PG spectrometer"
sendels 1.1 387 units : nm
388
sendels 4.1 389 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 390
391 ==== Electron Beam properties (FLASH1) ====
392
393 ===== bunch charge =====
394
sndueste 79.1 395 {{code language="none"}}/FL1/Electron Diagnostic/Bunch charge/after undulator{{/code}}
396 //always saved (PBD)//
397 DOOCS prop : {{code language="none"}}FLASH.DIAG/TOROID.ML/12EXP/CHARGE.FLASH1{{/code}}
398 DAQ channel: {{code language="none"}}FLASH.DIAG/TOROID/12EXP{{/code}}
399 desc: electron bunch charge (FLASH1)
sendels 1.1 400 units: nC
401
sndueste 5.1 402 =====
sndueste 57.1 403 arrival time (BAM) =====
sendels 1.1 404
sndueste 57.1 405 {{info title="BAM information: updates 2022"}}
sndueste 59.1 406 * see: [[Info collection about the BAMs and how to use the BAM data>>url:https://confluence.desy.de/display/FLASHUSER/Info+collection+for+the+BAM||shape="rect"]]
sndueste 57.1 407 * The data format of the BAM has been completely altered in the 2022 shutdown
408 * before 2022 BAMs were always saving the arrival time information for each 1µs bucked regardless if there were electrons in the accelerator or not. IN addition the arrival times for  FL1 and FL2 were saved in the same parameter ...
sndueste 61.1 409 * THIS is now different. There are new parameters saving only the arrival times for pulses that go to FL1 and to FL2 (in detail: first time slot of the accelerator and second)
sndueste 57.1 410 * There has been also a renaming  (and relocation) of the BAMs.
411 ** acc:  4DBC3 → FL0.DBC2
412 ** FL1: 1SFELC →  FL1.SFELC
sndueste 79.1 413 ** FL2: FL2XTDS → (% style="color:#172b4d" %)FL2.SEED5
sndueste 57.1 414 * for more Info: [[LINK to detailed infos from MSK>>url:https://confluence.desy.de/display/SDiagPublic/BAM+Data+Structure||shape="rect"]]
415 * [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments>>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
416 * a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
417 {{/info}}
418
419 {{expand title="Discontinued BAM format (used until end 2021)"}}
sndueste 79.1 420 (% style="color:#000000" %)**Discontinued BAM data recording **
sndueste 57.1 421
sndueste 79.1 422 {{code language="none"}}/FL1/Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}}
423 //always saved (PBD)//
424 DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
425 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
426 desc: Electron bunch arrival time measured with the BAM inside the accelerator - however shows a very good correlation to the arrivaltime  of the XUV pulses in the experiment (pulse resolved data).
sndueste 33.1 427 units: ps (bigger numbers indicate later arrivaltime of the electrons)
sendels 1.1 428
sndueste 58.1 429
sndueste 79.1 430 {{code language="none"}}/FL1/Electron Diagnostic/BAM/1SFELC/electron bunch arrival time (low charge){{/code}}
431 //always saved (PBD)//
432 DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/1SFELC/LOW_CHARGE_ARRIVAL_TIME{{/code}}
433 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/1SFELC.LOW_CHARGE_ARRIVAL_TIME{{/code}}
434 desc: Electron bunch arrival time measured with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020.
sndueste 58.1 435 units: ps (bigger numbers indicate later arrival time of the electrons)
sndueste 57.1 436 {{/expand}}
sndueste 33.1 437
sndueste 68.1 438 ====== **BAM FL0.DBC2**{{code language="none"}}{{/code}} ======
439
sndueste 79.1 440 (% style="color:#ff6600" %)**DBC2**/electron bunch arrival time  (HDF5 name not yet implemented - see zraw)(%%)
sndueste 68.1 441 //always saved (PBD)//
sndueste 74.1 442 {{code language="none"}}/FL1/Electron Diagnostic/BAM/ {{/code}}DOOCS prop : FLASH.SDIAG/BAM/**FL0.DBC2**/ARRIVAL_TIME.ABSOLUTE.SA1.COMP
sndueste 79.1 443 DAQ (% style="color:#000000" %)channel: FLASH.SDIAG/BAM/**FL0.DBC2**/ARRIVAL_TIME.ABSOLUTE.SA1.COMP (%%)
sndueste 74.1 444 desc: Electron bunch arrival time measured with the BAM inside the accelerator (after bunch compressor 2). The property contains only the arrival time of the bunches sent to FL1 (e.g. if there are 30 bunches in FL1 the first 30 values are the arrival time the remaining numbers  still may have arbitrary numbers looking like a signal which they are not ). These are the same values as the "raw" data below - just "cleaned". The values show a very good correlation to the arrival time  of the XUV pulses in the experiment (see help).
sndueste 68.1 445
sndueste 74.1 446 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
sndueste 68.1 447
448
sndueste 79.1 449 (% style="color:#ff6600" %)DBC2/electron bunch arrival time (raw)  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL1/Electron Diagnostic/BAM/{{/code}}(%%)
450 //always saved (PBD)//
sndueste 67.1 451 DOOCS prop : FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.ABSOLUTE
sndueste 79.1 452 DAQ channel: (% style="color:#000000" %)FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.ABSOLUTE (%%)
sndueste 68.1 453 desc: Electron bunch arrival time measured with the BAM inside the accelerator (after bunch compressor 2). Here the complete bunch train from the FEL is recorded (FLASH1 and FLASH2 pulses). Thus there are values from FLASH 1 in the first part. they may be separated by several "0" values if the reprate is different from 1 MHz ...  - It shows a very good correlation to the arrival time  of the XUV pulses in the experiment (see help). 
sndueste 58.1 454 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
455
sndueste 57.1 456
sndueste 79.1 457 (% style="color:#ff6600" %)DBC2/error (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL1/Electron Diagnostic/BAM/{{/code}}(%%)
458 //always saved (PBD)//
459 DOOCS prop : FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIM(% style="color:#000000" %)E.bamError(%%)
460 DAQ channel: (% style="color:#000000" %)FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.BAMERROR(%%)
sndueste 58.1 461 desc: If the value is 0 , the BAM is working well. If it is non-zero there is a problem !!
sndueste 57.1 462
sndueste 58.1 463
sndueste 79.1 464 (% style="color:#ff6600" %)DBC2/status  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL1/Electron Diagnostic/BAM/{{/code}}(%%)
465 //always saved (PBD)//
466 DOOCS prop : FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIM(% style="color:#000000" %)E..bamStatus.//1//(%%)
467 DAQ channel(% style="color:#000000" %): FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.BAMSTATUS.1(%%)
468 desc: (% style="letter-spacing:0.0px" %) status bit: 0 - data is valid; 1 - beam present; 2 - calibration ongoing; 3 - feedback enabled; 4 - feedback acting;  mostly check for bit 0 == 1 is sufficient
sndueste 57.1 469
470
sndueste 68.1 471 ====== **BAM FL1.SFELC**{{code language="none"}}{{/code}} ======
472
sndueste 79.1 473 (% style="font-family:SFMono-Medium,~"SF Mono~",~"Segoe UI Mono~",~"Roboto Mono~",~"Ubuntu Mono~",Menlo,Courier,monospace; letter-spacing:0.0px" %)/FL1/Electron Diagnostic/BAM/**SFELC**(% style="color:#ff6600" %)/electron bunch arrival time  (HDF5 name not yet implemented - see zraw)
sndueste 68.1 474
475 //always saved (PBD)//
sndueste 79.1 476 (% style="color:#172b4d" %)**FL1.SFELC**(%%)
477 (% style="color:#000000" %)channel: FLASH.SDIAG/BAM/(% style="color:#172b4d" %)FL1.SFELC(% style="color:#000000" %)/ARRIVAL_TIME.ABSOLUTE.SA1.COMP
478 {{code language="none"}} DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIME.ABSOLUTE.SA1.COMPDAQ {{/code}}(% style="letter-spacing:0.0px" %)desc: Electron bunch arrival time measured  with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020.. The property contains only the arrival time of the bunches sent to FL1 (e.g. if there are 30 bunches in FL1 the first 30 values are the arrival time the remaining numbers still may have arbitrary numbers looking like a signal which they are not). These are the same values as the "raw" data below - just "cleaned". The values show a very good correlation to the arrival time  of the XUV pulses in the experiment (see help).
sndueste 68.1 479 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
480
481
482
sndueste 79.1 483 (% style="color:#172b4d" %)SFELC(% style="color:#ff6600" %)/electron bunch arrival time (raw) (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL1/Electron Diagnostic/BAM/{{/code}}(%%)
484 //always saved (PBD)//
485 DOOCS prop : FLASH.SDIAG/BAM/(% style="color:#172b4d" %)FL1.SFELC(%%)/ARRIVAL_TIME.ABSOLUTE
486 DAQ channel:** **(% style="color:#000000" %)FLASH.SDIAG/BAM/FL1.SFELC/ARRIVAL_TIME.ABSOLUTE (%%)
sndueste 68.1 487 desc: Electron bunch arrival time measured  with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020. Here the complete bunch train from the FEL is recorded (FLASH1 and FLASH2 pulses). Thus there are values from FLASH 1 in the first part. they may be separated by several "0" values if the reprate is different from 1 MHz ...  - It shows a very good correlation to the arrival time  of the XUV pulses in the experiment (see help). 
sndueste 58.1 488 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
489
490
sndueste 79.1 491 (% style="color:#172b4d" %)SFELC(% style="color:#ff6600" %)/error (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL1/Electron Diagnostic/BAM/{{/code}}(%%)
492 //always saved (PBD)//
493 DOOCS prop : FLASH.SDIAG/BAM/(% style="color:#172b4d" %)FL1.SFELC(%%)/ARRIVAL_TIM(% style="color:#000000" %)E.bamError(%%)
494 DAQ channel(% style="color:#000000" %): FLASH.SDIAG/BAM/FL1.SFELC/ARRIVAL_TIME.BAMERROR(%%)
sndueste 58.1 495 desc: If the value is 0 , the BAM is working well. If it is non-zero there is a problem !!
496
497
sndueste 79.1 498 (% style="color:#172b4d" %)SFELC(% style="color:#ff6600" %)/status  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL1/Electron Diagnostic/BAM/{{/code}}(%%)
499 //always saved (PBD)//
500 DOOCS prop : FLASH.SDIAG/BAM/(% style="color:#172b4d" %)FL1.SFELC(%%)/ARRIVAL_TIM(% style="color:#000000" %)E..bamStatus.//1//(%%)
501 DAQ chann(% style="color:#000000" %)el: FLASH.SDIAG/BAM/FL1.SFELC/ARRIVAL_TIME.BAMSTATUS.1(%%)
sndueste 59.1 502 desc: status bit: 0 - data is valid; 1 - beam present; 2 - calibration ongoing; 3 - feedback enabled; 4 - feedback acting;  mostly check for bit 0 == 1 is sufficient
sndueste 58.1 503
504
sndueste 33.1 505
sendels 1.1 506 ===== electron beam profile =====
507
sndueste 79.1 508 {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/TDS profile{{/code}}
509 //always saved (PBD) - IF LOLA is ON and ACTIVATED in the PBD DAQ (talk to expert)//
510 DOOCS prop : {{code language="none"}}TTF2.DAQ/BEAM.PROF.ML/BEAM.PROF/OUT.PROF.CCCED{{/code}}
511 DAQ channel: {{code language="none"}}PBD.BEAM.PROF.ML/DAQ.OUT.PROF.CCCED{{/code}}
512 desc: temporal profile of electron bunch, y axis in Ampers (FLASH1)
sendels 1.1 513 units: pixel
sndueste 79.1 514
sendels 1.1 515
sndueste 79.1 516 {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/Expert stuff/TDS calibration constant{{/code}}
517 //always saved (PBD) - IF LOLA is ON and ACTIVATED in the PBD DAQ (talk to expert)//
518 DOOCS prop : {{code language="none"}}TTF2.DAQ/BEAM.PROF.ML/BEAM.PROF/CALIB.CONST.T{{/code}}
519 DAQ channel: = PBD.BEAM.PROF.ML/CCT=
520 desc: TDS calibration constant for the x-axis of the profiles: fs per pixel
sendels 1.1 521 units: fs per pixel
sndueste 79.1 522
sendels 1.1 523
sndueste 79.1 524 {{code language="none"}}/FL1/Electron Diagnostic/Electron bunch profile/TDS profile width rms{{/code}}
525 //always saved (PBD) - IF LOLA is ON and ACTIVATED in the PBD DAQ (talk to expert)//
526 DOOCS prop : {{code language="none"}}TTF2.DAQ/BEAM.PROF.ML/BEAM.PROF/SOWS.W.CCTED{{/code}}
527 DAQ channel: {{code language="none"}}PBD.BEAM.PROF.ML/PROFWIDTHCCTED{{/code}}
528 desc: rms pulse width of the measures TDS electron bunch profile
sendels 1.1 529 units: fs
530
531 ===== electron bunch energy =====
532
sndueste 79.1 533 {{code language="none"}}/FL1/Electron Diagnostic/Electron energy/average electron energy{{/code}}
534 //always saved (PBD)//
535 DOOCS prop : {{code language="none"}}TTF2.DAQ/ENERGY.DOGLEG/E_INTRA_MEAN/VAL{{/code}}
536 DAQ channel: {{code language="none"}}PBD.ENERGY.DOGLEG/E_MEAN{{/code}}
537 desc: electron bunch energy (average over the bunch train)
sendels 2.1 538 units: (% class="twikiNewLink" %)MeV(%%)
sndueste 79.1 539
sendels 1.1 540
sndueste 79.1 541 {{code language="none"}}/FL1/Electron Diagnostic/Electron energy/pulse resolved energy{{/code}}
542 //always saved (PBD)//
543 DOOCS prop : {{code language="none"}}TTF2.DAQ/ENERGY.DOGLEG/E_SPECT/VAL.TD{{/code}}
544 DAQ channel: {{code language="none"}}PBD.ENERGY.DOGLEG/E_SPECT{{/code}}
545 desc: electron bunch energy bunch resolved
sndueste 5.1 546 units: (% class="twikiNewLink" %)MeV
sendels 1.1 547
548
sndueste 79.1 549 {{code language="none"}}/FL1/Electron Diagnostic/Electron energy/wavelength bunch train average{{/code}}
550 //always saved (PBD)//
551 DOOCS prop : {{code language="none"}}TTF2.DAQ/ENERGY.DOGLEG/LAMBDA_MEAN/VAL{{/code}}
552 DAQ channel: {{code language="none"}}PBD.ENERGY.DOGLEG/LAMBDA_MEAN{{/code}}
553 desc: Wavelength calculated by the electron bunch energy (average over the bunch train) (FLASH1)
sendels 1.1 554 units: nm
sndueste 79.1 555
sendels 1.1 556
sendels 4.1 557 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 558
559
sndueste 5.1 560 ==== Timing information, rep rate etc.  (FLASH1) ====
sendels 1.1 561
562 ===== bunch repetition rate =====
563
sndueste 79.1 564 {{code language="none"}}/FL1/Timing/repetition rate{{/code}}
565 //always saved (PBD)//
566 DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/REP_RATE_KHZ.1{{/code}}
567 DAQ channel: {{code language="none"}}TTF2.UTIL/LASER.CONTROL/GUN/PULSE_FREQ{{/code}}
sendels 1.1 568 desc: repetition rate of the bunches / pulses within the burst (FLASH1)
569 units: kHz
sndueste 79.1 570
sendels 1.1 571
572 ===== set number of pulses =====
573
sndueste 79.1 574 (% style="color:#ff6600" %)(HDF5 name not yet implemented - see zraw)(% style="color:#ff0000" %){{code language="none"}}/FL1/Timing/set number of bunches {{/code}}(%%)
575 //always saved (PBD)//
sndueste 74.1 576 DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMINGINFO/TIME1.BUNCH_FIRST_INDEX.1 [4th number]{{/code}}
577 DAQ channel: {{code language="none"}}FLASH.DIAG/TIMINGINFO/TIME1.BUNCH_FIRST_INDEX.1 [4th number]{{/code}}
578 desc: Number of bunches set in the control (timing) system.  The property contains 4 numbers. the last one is the number of pulses (see also [[doc:FLASH.Timing properties]] (internal link)).  If pulses are used for diagnostic of the protection system of the accelerator limits the number of bunches to be accelerated and thus the actual number of pulses may be smaller than the set one 
sendels 1.1 579 units:
580
581 ===== actual number of pulses =====
582
sndueste 79.1 583 {{code language="none"}}/FL1/Timing/actual number of bunches{{/code}}
584 //always saved (PBD)//
585 DOOCS prop : {{code language="none"}}FLASH.DIAG/TOROID.ML/12EXP/NUMBEROFBUNCHES.FLASH1{{/code}}
586 DAQ channel: {{code language="none"}}TTF2.DIAG/PBD.TOROID.ML/12EXP{{/code}}
587 desc: Number of bunches measured BEHIND the undulator. If pulses are used for diagnostic of the protection system of the accelerator limits the number of bunches to be accelerated this is the actual number that created XUV radiation.The number is calculated by the DAQ middle layer server, (FLASH1)
sendels 1.1 588 units:
sndueste 79.1 589
sendels 1.1 590
591 ===== actual pulse pattern recorded after the undulator =====
592
sndueste 79.1 593 {{code language="none"}}/FL1/Timing/Bunch pattern/pattern after undulator{{/code}}
594 //always saved (PBD)//
595 DOOCS prop : {{code language="none"}}TTF2.DIAG/PBD.TOROID.ML/12EXP/CHARGE.TD{{/code}}
596 DAQ channel: {{code language="none"}}TTF2.DIAG/PBD.TOROID.ML/12EXP{{/code}}
597 desc: The bunch pattern as function of time in a burst recorded by toroid diagnostic BEHIND the undulator. (FLASH1)
sendels 1.1 598 units:
sndueste 79.1 599
sendels 1.1 600
601 ===== Train ID =====
602
sndueste 79.1 603 {{code language="none"}}/Timing/train ID{{/code}}
604 //always saved (PBD)//
605 DOOCS prop : {{code language="none"}}none{{/code}}
606 DAQ channel: {{code language="none"}}none{{/code}}
607 desc: Each 10 Hz burst has its unique train ID. For the HDF5 data set the ID is the same for all parameters with the same index (note camera images may be shifted by 1 ID - talk to the experts !)
sendels 1.1 608 units:
sndueste 79.1 609
sendels 1.1 610
611 ===== Train time =====
612
sndueste 79.1 613 {{code language="none"}}/Timing/train time{{/code}}
614 desc:Local time as array of day, hour, minute, second, and centisecond. This data set is meant for visualization purposes only. For correlations use the train ID or the Unix time of the time stamp
sendels 1.1 615 units: d h min s cs
sndueste 79.1 616
sendels 1.1 617
sndueste 79.1 618 {{code language="none"}}/Timing/time stamp{{/code}}
619 desc:first column: Local time in unix time. To get day, hour, minute, second you can use unix: e.g. date ~-~-date='@1553617729' or matlab, python etc
620 second column: microseconds
sendels 1.1 621 third column: Train ID of FLASH
sndueste 79.1 622
sendels 1.1 623
sendels 4.1 624 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 625
626
627 ==== Pump Probe Laser (FLASH1) ====
628
sndueste 63.1 629 **PIGLET (PG laser)**
sndueste 62.1 630
sndueste 63.1 631 **{{code language="none"}}/FL1/Experiment/Pump probe laser{{/code}}**
632
sndueste 82.1 633 {{info width="100"}}
sndueste 80.1 634 list of saved parameters status May 2024 (up to now the parameters can be found in /zraw/ ... )
sndueste 63.1 635
sndueste 81.1 636
sndueste 82.1 637 Download the PDF:
638
639 [[~[~[image:Screenshot 2024-05-17 094435.png~|~|height="429" width="336"~]~]>>attach:FSLADAQ-DAQParameterlistPiGLET.pdf]]
sndueste 81.1 640
sndueste 80.1 641 {{/info}}
sndueste 69.1 642
sndueste 62.1 643 {{expand title="Parameters used until 2021"}}
sndueste 79.1 644 {{code language="none"}}
645 /FL1/Experiment/Pump probe laser/laser attenuation
646 {{/code}}
sndueste 5.1 647
sndueste 79.1 648 //always saved (PBD)//
649 DOOCS prop : {{code language="none"}}TTF2.FEL/PPDELAYCAL/PPDELAYCAL/ROT2.CURRENT{{/code}}
650 DAQ channel: {{code language="none"}}TTF2.FEL/PPDELAYCAL/PPDELAYCAL/ROT2.CURRENT{{/code}}
651 desc: attenuation of the PPLaser (rotation of a waveplate)
sendels 1.1 652 units : 0 no transmission , 1: full transmission
653
sndueste 5.1 654
sndueste 79.1 655 {{code language="none"}}/FL1/Experiment/Pump probe laser/laser delay{{/code}}
656 //always saved (PBD)//
657 DOOCS prop : {{code language="none"}}TTF2.FEL/PPDELAYCAL/PPDELAYCAL/DLY1.CURRENT{{/code}}
658 DAQ channel: {{code language="none"}}TTF2.FEL/PPDELAYCAL/PPDELAYCAL/DLY1.CURRENT{{/code}}
659 desc: delay of the Pump probe laser - measured by the read back position of the motor. only read out every secound ... better use the encoder
sendels 1.1 660 units : ps ( pos delay means IR comes later)
661
sndueste 5.1 662
sndueste 79.1 663 {{code language="none"}}/FL1/Experiment/Pump probe laser/delay line IK220.0/ENC.DELAY{{/code}}
664 //always saved (PBD)//
665 DOOCS prop : {{code language="none"}}TTF2.FEL/DELLINE.ENC/IK220.0/ENC.DELAY{{/code}}
666 DAQ channel: {{code language="none"}}TTF2.FEL/DELLINE.ENC/IK220.0:ENC.DELAY{{/code}}
667 subsystem: {{code language="none"}}DELLINE.ENC{{/code}} desc : delay of the Pump probe laser - measured by an encoder. The position is read out with 10Hz train synchronized and should be used to determine the actual laser delay (the motor position is only read out about every second
sendels 1.1 668 units : ps ( pos delay means IR comes later)
669
sndueste 5.1 670
sndueste 79.1 671 {{code language="none"}}/FL1/Experiment/Pump probe laser/Synchronization/timing jitter RMS GECCO{{/code}}
672 //always saved (PBD)//
673 DOOCS prop : {{code language="none"}}FLASH.SYNC/F1PPL.LASER_LOCK/28C.F1PPL1.CONTROLLER/ADV_CTRL_MANAGER.0.PID_INPUT_JITTER.2.RD{{/code}}
674 DAQ channel: {{code language="none"}}FLASH.SYNC/F1PPL.LASER_LOCK/28C.F1PPL1.CONTROLLER/ADV_CTRL_MANAGER.0.PID_INPUT_JITTER.2.RD{{/code}}
sendels 2.1 675 desc: rms jitter of the GECCO (% class="twikiNewLink" %)TiSa(%%) Oscillator units: fs
sendels 1.1 676
677
sndueste 79.1 678 {{code language="none"}}/FL1/Experiment/Pump probe laser/streak camera delay time{{/code}}
679 //always saved (PBD)//
680 DOOCS prop : {{code language="none"}}TTF2.FEL/TDOLFEL/TDOLFEL/STREAK.CAM.TIME{{/code}}
681 DOOCS prop : {{code language="none"}}TTF2.FEL/TDOLFEL/TDOLFEL/STREAK.CAM.TIME{{/code}}
sndueste 52.1 682 desc: delay time between the optical laser and the FEL units: ps
sndueste 62.1 683 {{/expand}}
sendels 1.1 684
685
sendels 4.1 686 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 687
688
689 ==== User Data (FLASH1) ====
690
sndueste 52.1 691 The data saved specifically for detectors at an experiment will show up in /Experiment/ there is a large number of options for cameras or monitoring of slow properties (motor positions etc) for user experiments. For details please ask your local contact.
sndueste 18.1 692
693 NOTE: If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with the DOOCS names
694
695 The most common and permanently installed device used by experiment are our ADCs:
696
sendels 1.1 697 ===== GHz ADCs =====
698
sndueste 79.1 699 ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found** [[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]]**
700 //saved on DEMAND in the user DAQ//
sendels 1.1 701 \\The HDF5 names for the ADC traces are depending on the beamline :
sndueste 79.1 702 \\PG Beamline:
703 {{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH00/TD{{/code}}
704 {{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH01/TD{{/code}}
705 {{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH02/TD{{/code}}
sendels 1.1 706 {{code language="none"}}/FL1/Experiment/PG/ADQ412 GHz ADC/CH03/TD{{/code}}
707
sndueste 79.1 708 BL Beamlines:
709 {{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH00/TD{{/code}}
710 {{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH01/TD{{/code}}
711 {{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH02/TD{{/code}}
712 {{code language="none"}}/FL1/Experiment/BL1/ADQ412 GHz ADC/CH03/TD{{/code}}
713 \\{{code language="none"}}/FL1/Experiment/BL2/ADQ412 GHz ADC/CH00/TD{{/code}}
714 {{code language="none"}}/FL1/Experiment/BL2/ADQ412 GHz ADC/CH01/TD{{/code}}
715 \\{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH02/TD{{/code}}
sendels 1.1 716 {{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH03/TD{{/code}}
717
sndueste 79.1 718 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
sndueste 52.1 719 here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} contains only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is used preferably.
sendels 1.1 720 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}}
721
sndueste 18.1 722 In addition there are also additional parameters saved like:
sendels 1.1 723
sndueste 16.1 724 * {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains.
sndueste 52.1 725 * {{code language="none"}}number of samples{{/code}}: total number of samples recorded for each 10 Hz trigger
sndueste 79.1 726 * {{code language="none"}}error (ADC):{{/code}}0 indicates that there was no error
sendels 1.1 727
728 ===== MHz ADCs =====
729
sndueste 79.1 730 similar to the GHz ADCs the MHz ADCs are saved with HDF5 names like:
731 {{code language="none"}}/FL1/Experiment/BL1/SIS8300 100MHz ADC/CH2/TD{{/code}}
732 DOOCS prop : FLASH.FEL/ADC.SIS.BL1/EXP1.CH02/CH00.TD
sendels 1.1 733 DAQ channel: : FLASH.FEL/ADC.SIS.BL1/EXP1.CH02
734
sndueste 18.1 735 In addition there are also additional parameters saved like:
sendels 1.1 736
sndueste 18.1 737 * {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains.
sndueste 52.1 738 * {{code language="none"}}number of samples{{/code}}: total number of samples recorded for each 10 Hz trigger
sndueste 18.1 739
sendels 4.1 740 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 741
sndueste 18.1 742
743
744
sendels 1.1 745 === FLASH2 ===
746
sndueste 7.1 747 There is analog to FLASH1 a permanently running "PhotonDagnostic DAQ FLASH2" (PBD2) and 2 User DAQs
sendels 1.1 748
sndueste 7.1 749 ==== Beamline info (FLASH2) ====
sndueste 6.1 750
sndueste 79.1 751 {{code language="none"}}/FL2/Beamlines/Attenuator/pressure  {{/code}}
752 (% style="color:#000000" %)//always saved (PBD2)// (%%)
753 (% style="color:#000000" %)DOOCS prop : {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} (%%)
754 (% style="color:#000000" %)DAQ channel:  {{code language="none"}}FLASH.FEL/ATT.GAS_DOSING/FL2.HALL/PRESSURE{{/code}} (%%)
755 (% style="color:#000000" %)desc: set pressure in the gas attenuator (%%)
756 (% style="color:#000000" %)units: mbar(%%)
757
sndueste 5.1 758
sndueste 79.1 759 {{code language="none"}}/FL2/Beamlines/FL20/Shutter/open{{/code}}
760 //always saved (PBD2)//
761 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.SIS.FL2FS/FL20.SHUTTER/CH00.TD{{/code}}
762 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.SIS.FL2FS/FL20.SHUTTER{{/code}}
763 desc: BL Beamline Fast shutter state: 1 is open, 0 is closed ( for technical reasons there are 100 vales of this state saved ...)
sndueste 6.1 764 units: none
sndueste 5.1 765
766
sndueste 79.1 767 {{code language="none"}}/FL2/Beamlines/Filter wheel/position wheel 1{{/code}}
768 //always saved (PBD2)//
769 DOOCS prop : {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS{{/code}}
770 DAQ channel: FLASH.FEL/FL20H.PH.MOTOR/MOTOR1.MOT3/FPOS
sndueste 24.1 771 desc: Position of the BL filter wheel 1 - to correlate with the filter material please look **[[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filter wheels in FLASH1 and FLASH2.WebHome]]**
sndueste 6.1 772 units: degree
sndueste 79.1 773
sndueste 6.1 774
sndueste 79.1 775 /FL2/Beamlines/Filter wheel/position wheel 2
776 always saved (PBD2)
777 DOOCS prop : {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS{{/code}}
778 DAQ channel: {{code language="none"}}FLASH.FEL/FL20H.PH.MOTOR/MOTOR2.MOT3/FPOS{{/code}}
sndueste 40.1 779 desc: Position of the BL filter wheel 2 - to correlate with the filter material please look [[here>>doc:FLASHUSER.jddd-linked help pages.Filter-Units.Filter wheels in FLASH1 and FLASH2.WebHome]]
780 units: degree
sndueste 6.1 781
sndueste 8.1 782
783 NOTE: Aperture positions in the beamline as well as the positions of the beam steering mirrors are also saved. for more Info contact your local contact
784
sndueste 6.1 785 [[Contents>>doc:||anchor="Contents"]]
786
787
788
sndueste 10.1 789 ==== Photon Diagnostics SASE ([[XGMD>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/gmd_intensity_and_position/index_eng.html||shape="rect"]] - FLASH2) ====
sndueste 8.1 790
sndueste 79.1 791 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}}
792 //always saved (PBD2)//
793 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}}
794 DAQ channel:{{code language="none"}} FLASH.FEL/XGM.PHOTONFLUX/FL2.TUNNEL/PHOTONFLUX.UJ{{/code}}
795 desc : calibrated average ( ~~ 20 sec averaging time ) SASE Energy/pulse measured in the TUNNEL before the attenuator (ion current)
sndueste 8.1 796 units : microJ
797
798
sndueste 79.1 799 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}}
800 //always saved (PBD2)//
801 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
802 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL2.TUNNEL/INTENSITY.TD{{/code}}
sndueste 38.1 803 desc : Energy per pulse measured in the Tunnel  (in front of the gas attenuator and the apertures in the Hall) In addition measurement errors and beam position are included for EACH pulse in the pulse train  !! (see below)
sndueste 23.1 804 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FLASHUSER.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]**
sndueste 8.1 805
sndueste 39.1 806 {{info title="GMD pulse resolved data structure"}}
sndueste 79.1 807 For every pulse in the pulse train the information is saved:
sndueste 38.1 808
sndueste 8.1 809
sndueste 38.1 810 1. **Intensity per pulse** (a.u. (more or less µJ ))
811 1. Intensity per pulse (auxillary GMD) - not used
sndueste 39.1 812 1. Position horizontal (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
813 1. Position vertical (mm, for a single pulse the position information may be very noisy  - talk to your local contact)
sndueste 79.1 814 1. **Intensity per pulse sigma** (a.u. (more or less µJ ), (% style="color:#000000" %)This parameter gives an indication of the error of the measurement of the pulse energy. This takes signal to noise,  detector resolution, uncertainties in crossection etc into account. (it is NOT the measurement of the statistical fluctuation of the SASE pulses)(%%))
sndueste 38.1 815 1. Position horizontal sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
816 1. Position vertical sigma  (mm, indicates the error (RMS, sigma) of the measurement according to known uncertainties and signal to noise)
817 1. Combined warning and error flags
sndueste 8.1 818
sndueste 38.1 819 The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 
820 file
sndueste 8.1 821
sndueste 38.1 822
823 [[image:attach:image2021-2-9_10-51-6.png||height="250"]]
sndueste 8.1 824
sndueste 79.1 825
sndueste 39.1 826 {{/info}}
sndueste 38.1 827
sndueste 8.1 828
sndueste 79.1 829 All values for the GMD are also available for the** HALL GMD **which is located in the experimental hall down stream the gas attenuator. If the attenuator is on the ratio between Hall and Tunnel signal shows the attenuation. **BUT NOTE** that the filter unit and the Aperture 4 are downstream the GMD. So if filters and aperture are used this influence is NOT measured by the GMD hall !
sndueste 8.1 830
831
sndueste 9.1 832 Besides  pulse energy the GMD also provides information about the beam position
sndueste 8.1 833
sndueste 9.1 834
sndueste 79.1 835 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel horizontal{{/code}}
836 //always saved (PBD2)//
837 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}}
838 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IX.POS{{/code}}
839 desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the GMD (tunnel, x=horizontal)
sndueste 8.1 840 units : mm
841
sndueste 9.1 842
sndueste 79.1 843 {{code language="none"}}/FL2/Photon Diagnostic/GMD/Average Beam position/position tunnel vertical{{/code}}
844 //always saved (PBD2)//
845 DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}}
846 DAQ channel: {{code language="none"}}FLASH.FEL/XGM.POSMON/FL2.TUNNEL/IY.POS{{/code}}
847 desc : the Average ( ~~ 20 sec averaging time ) Beam position of the photon Beam determined by the GMD (tunnel, x=horizontal)
sndueste 8.1 848 units : mm
849
850
sndueste 79.1 851 /FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel x
sndueste 40.1 852 always saved (PBD2)
853 DOOCS prop : FLASH.FEL/XGM.BPM/FL2.HALL/X.TD
sndueste 79.1 854 DAQ channel: FLASH.FEL/XGM.BPM/FL2.HALL:2
sndueste 40.1 855 desc: Besides the well calibrated averaged beam position information there is also the option to measure the beam position on a single bunch level. HOWEVER this methide needs a perfectly adjusted signal level (talk to your local contact !!) and also then the signal to noise is rather small and one needs some averaging ... BUT with this option one can determine if there was a spatial slope on a burst (say forst bunches were lower than the last ones or so ...)
856 units : mm   
sndueste 8.1 857
sndueste 40.1 858 (x=horizontal, y = vertial)
sndueste 9.1 859
860 again the same parameter set is available for the **HALL GMD**
861
sndueste 8.1 862
sndueste 9.1 863
sndueste 15.1 864 ==== Photon Diagnostics OPIS[[ >>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]](FLASH2) ====
sndueste 10.1 865
sndueste 19.1 866 for more info see:** [[ OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]]**
sndueste 10.1 867
868 (The OPIS hall is not installed yet ...)
869
sndueste 9.1 870
sndueste 10.1 871 {{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean photon energy{{/code}}
sndueste 79.1 872 // saved opon request (PBD2)//
873 DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}}
874 DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL042{{/code}}
sndueste 10.1 875 desc : mean photon energy ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy)
876 units : eV
877
sndueste 9.1 878
sndueste 10.1 879 {{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/mean wavelength{{/code}}
sndueste 79.1 880 // saved opon request (PBD2)//
881 DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}}
sndueste 10.1 882 DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL040{{/code}}
sndueste 52.1 883 desc : mean wavelength ( ~~ 1 sec averaging time ) measured in the TUNNEL for a specific bunch out of the bunch train (via photoelectron spectroscopy)
sndueste 10.1 884 units : nm
885
sndueste 9.1 886
sndueste 10.1 887 {{code language="none"}}/FL2/Photon Diagnostic/Wavelength/OPIS tunnel/Processed/number of analyzed bunch        (in older version this can be found in OPIS tunnel/Expert stuff/General operation parameters/){{/code}}
sndueste 79.1 888 // saved opon request (PBD2)//
889 DOOCS prop : {{code language="none"}}FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}}
sndueste 10.1 890 DAQ channel:{{code language="none"}} FLASH.UTIL/STORE/FL2.TUNNEL.OPIS/VAL060{{/code}}
sndueste 11.1 891 desc : The bunch number of the bunch used for the wavelength calculation
892 units :
sndueste 10.1 893
sndueste 9.1 894
sndueste 52.1 895 If Opis is running typically on the the averaged data is saved. For several experiments it may make sense to save the information for each single bunch. This is up to now done by saving the complete ADC trace of the TOF setup. This is a huge amount of data and needs processing. This has to be performed after the beamtime in close contact to [[Markus Braune>>mailto:markus.braune@desy.de||shape="rect"]] ( responsible for [[OPIS>>url:http://photon-science.desy.de/facilities/flash/photon_diagnostics/opis_spectrometer/index_eng.html||shape="rect"]])
sndueste 11.1 896
sndueste 9.1 897
sndueste 52.1 898 In case OPIS was not operating there is still information about the **set wavelength** for the undulators (see below) which may differ by up to 5 % from the actual wavelength due to different settings in the FEL ...
sndueste 12.1 899
sndueste 9.1 900
901
sndueste 12.1 902 ==== Electron Beam properties (FLASH2) ====
903
904 ===== bunch charge =====
905
sndueste 79.1 906 {{code language="none"}}/FL2/Electron Diagnostic/Bunch charge/after undulator{{/code}}
907 //always saved (PBD2)//
sndueste 12.1 908 DOOCS prop : {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN/CHARGE.FLASH2{{/code}}
sndueste 79.1 909 DAQ channel: {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN/CHARGE.FLASH2{{/code}}
910 desc: electron bunch charge FLASH2 (average value for each bunchtrain).
sndueste 12.1 911 units: nC
912
sndueste 9.1 913
sndueste 52.1 914 ===== electron bunch energy =====
sndueste 9.1 915
sndueste 52.1 916 {{code language="none"}}/FL2/Electron Diagnostic/Electron energy/energy of first bunch/behind undulators{{/code}}
sndueste 79.1 917 //always saved (PBD2)//
sndueste 52.1 918 DOOCS prop : {{code language="none"}}FLASH.DIAG/BEAM_ENERGY_MEASUREMENT/FL2XTDS/ENERGY.FLASH2{{/code}}
sndueste 79.1 919 DAQ channel: (% style="color:#5e6c84" %)TTF2.DAQ/PBD2.BEAM.ENERGY.MEAS.ML.COPY/FL2XTDS.ENERGY.FLASH2{{code language="none"}}{{/code}}(%%)
920 desc: electron bunch energy measured behind the undulator. Data is saved with 10 Hz - BUT (for computation reasons) only the energy of the FIRST bunch is recorded. The data is also available for (% style="color:#5e6c84" %)extraction and septum  in the beginning of FLASH2
sndueste 52.1 921
sndueste 79.1 922 (% style="letter-spacing:0.0px" %)units: (% class="twikiNewLink" %)MeV
sndueste 52.1 923
924
925 (% style="color: rgb(94,108,132);font-weight: 600;letter-spacing: 0.0px;" %)
926 undulator settings
927
sndueste 79.1 928 {{code language="none"}}/FL2/Electron Diagnostic/Undulator setting/set wavelength{{/code}}
929 //always saved (PBD2)//
sndueste 14.1 930 DOOCS prop : {{code language="none"}}TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH{{/code}}
sndueste 79.1 931 DAQ channel:  {{code language="none"}}TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH{{/code}}
sndueste 14.1 932 desc: Set value for the anticipated wavelength . This parameter is used to set the undulator gap. It may however deviate from the actual wavelength by several % ...
933 units: nm
sndueste 12.1 934
sndueste 79.1 935 {{code language="none"}}/FL2/Electron Diagnostic/Undulator setting/SASE14 gap{{/code}}
936 //always saved (PBD2)//
sndueste 14.1 937 DOOCS prop : {{code language="none"}}FLASH.UTIL/FL2.UND.MOTOR/FL2SASE14/GAP{{/code}}
sndueste 79.1 938 DAQ channel:  {{code language="none"}}FLASH.UTIL/FL2.UND.MOTOR/FL2SASE14/GAP{{/code}}
sndueste 15.1 939 desc: gap value of the undulators. This can be used to follow up how many undulators were closed and if there was a taper
sndueste 14.1 940 units: mm
941
sndueste 15.1 942 The gap values are saved for all 12 undulators (Nr 3 to 14). Undulator 14 is the one closest to the experimental hall.
sndueste 14.1 943
sndueste 12.1 944 =====
sndueste 59.1 945 arrival time (BAM) =====
sndueste 12.1 946
sndueste 59.1 947 {{info title="BAM information: updates 2022"}}
948 * see: [[Info collection about the BAMs and how to use the BAM data>>url:https://confluence.desy.de/display/FLASHUSER/Info+collection+for+the+BAM||shape="rect"]]
949 * The data format of the BAM has been completely altered in the 2022 shutdown
sndueste 60.1 950 * before 2022 BAMs were always saving the arrival time information for each 1µs bucked regardless if there were electrons in the accelerator or not. I addition the arrival times for  FL1 and FL2 were saved in the same parameter ...
sndueste 61.1 951 * THIS is now different. There are new parameters saving only the arrival times for pulses that go to FL1 and to FL2 (in detail: first time slot of the accelerator and second)
sndueste 59.1 952 * There has been also a renaming  (and relocation) of the BAMs.
953 ** acc:  4DBC3 → FL0.DBC2
954 ** FL1: 1SFELC →  FL1.SFELC
sndueste 79.1 955 ** FL2: 8FL2XTDS → (% style="color:#172b4d" %)FL2.SEED5
sndueste 59.1 956 * for more Info: [[LINK to detailed infos from MSK>>url:https://confluence.desy.de/display/SDiagPublic/BAM+Data+Structure||shape="rect"]]
957 * [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments>>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
958 * a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
959 {{/info}}
960
961 {{expand title="Discontinued BAM format (used until end 2021)"}}
sndueste 79.1 962 (% style="color:#000000" %)**Discontinued BAM data recording **
sndueste 59.1 963
sndueste 79.1 964 {{code language="none"}}/FL2/Electron Diagnostic/BAM/8FL2XTDS/electron bunch arrival time (low charge){{/code}}
965 //always saved (PBD2)//
966 DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/8FL2XTDS/LOW_CHARGE_ARRIVAL_TIME{{/code}}
967 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/8FL2XTDS.LOW_CHARGE_ARRIVAL_TIME{{/code}}
968 desc: Electron bunch arrival time measured with the BAM after the FLASH2 undulator (pulse resolved data)
sndueste 33.1 969 units: ps (bigger numbers indicate later arrivaltime of the electrons)
970
sndueste 79.1 971 **FL1**{{code language="none"}}//Electron Diagnostic/BAM/4DBC3/electron bunch arrival time (low charge){{/code}}
972 //always saved (PBD2)//
973 DOOCS prop : {{code language="none"}}FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME{{/code}}
974 DAQ channel: {{code language="none"}}FLASH.SDIAG/BAM.DAQ/4DBC3.LOW_CHARGE_ARRIVAL_TIME{{/code}}
975 desc: Electron bunch arrival time measured with the BAM  in the accelerator  (pulse resolved data)
sndueste 14.1 976 units: ps (bigger numbers indicate later arrivaltime of the electrons)
sndueste 12.1 977
sndueste 80.1 978 {{info title="BAM hints"}}
sndueste 79.1 979 * The BAM 4DBC3 measures the arrivaltime of** FLASH 1 and FLASH2** in the same data set (thus also sorted in at /FL1/ !).
sndueste 33.1 980 * The BAM 8FL2XTDS measures only for FLASH2 BUT has the same data structure as the other BAMS ... thus there are also (random) values in in the  FLASH1 time slot 
981 ** Structure: The first values are for FLASH1 bunches. After a gap of about 70 micros ( 70 colums)  with  as entry for the switching between FLASH 1 and 2 the values for the electrons used in FLASH2 start.  The start time of FLASH2 is also recorded in the DAQ. FLASH1 start time is for historic reasons 700. thus if e.g. the start time of FLASH2 ( property name see below) is 1200 it means that FLASH starts at column 500 (1200-700) ... .In case of doubt ask your local contact
982 * [[Link a collection of papers related to the BAM and the analysis of pump-probe experiments >>doc:FLASHUSER.Additional helpful things.FLASH beamlines and instruments references.WebHome]]
sndueste 79.1 983 * [[LINK to detailed infos from MSK (may only work inside DESY network~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|height="12" width="13"~]~]>>url:http://www.desy.de/~~mbock/pages/BAM_daq_channel_descriptions.html||shape="rect"]]
sndueste 33.1 984 * a recent  [[talk about the working principle of the BAM>>attach:BAM-basics and outlook-2018_DESY-template_16-9Format.pdf]]
985 {{/info}}
sndueste 59.1 986 {{/expand}}
sndueste 10.1 987
sndueste 68.1 988
989 ====== **BAM FL0.DBC2**{{code language="none"}}{{/code}} ======
990
sndueste 79.1 991 (% style="color:#ff6600" %)**DBC2**/electron bunch arrival time  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}
sndueste 73.1 992
sndueste 79.1 993 {{code language="none"}}
994 /zraw/FLASH.SDIAG/BAM.DAQ/FL0.DBC2.ARRIVAL_TIME.ABSOLUTE.SA2.COMP/dGroup/
995 {{/code}}
sndueste 73.1 996
sndueste 68.1 997 //always saved (PBD)//
998 **FL0.DBC2**
sndueste 79.1 999 (% style="color:#000000" %)channel: FLASH.SDIAG/BAM/**FL0.DBC2**/ARRIVAL_TIME.ABSOLUTE.SA2.COMP
1000 {{code language="none"}} DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIME.ABSOLUTE.SA2.COMPDAQ {{/code}}(% style="letter-spacing:0.0px" %)desc: Electron bunch arrival time measured with the BAM inside the accelerator (after bunch compressor 2). The property contains only the arrival time of the bunches sent to FL2 (e.g. if there are 30 bunches in FL2 the first 30 values are the arrival time the remaining numbers still may have arbitrary numbers looking like a signal which they are not0). These are the same values as the "raw" data below - just "cleaned". The values show a very good correlation to the arrival time  of the XUV pulses in the experiment (see help).
sndueste 68.1 1001 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
1002
1003
sndueste 79.1 1004 (% style="color:#ff6600" %)DBC2/electron bunch arrival time (raw)  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}
sndueste 73.1 1005
1006 {{code language="none"}}/zraw/FLASH.SDIAG/BAM.DAQ/FL0.DBC2.ARRIVAL_TIME.ABSOLUTE.SA2/dGroup/{{/code}}
sndueste 79.1 1007 //always saved (PBD)//
sndueste 68.1 1008 {{code language="none"}}DOOCS prop : FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.ABSOLUTE{{/code}}
sndueste 79.1 1009 (% style="color:#000000" %)FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.ABSOLUTE {{code language="none"}}DAQ channel: {{/code}}(%%)
sndueste 68.1 1010 desc: Electron bunch arrival time measured with the BAM inside the accelerator (after bunch compressor 2). Here the complete bunch train from the FEL is recorded (FLASH1 and FLASH2 pulses). Thus there are values from FLASH 2 in the second part. they may be separated by several "0" values if the reprate is different from 1 MHz ...  - It shows a very good correlation to the arrival time  of the XUV pulses in the experiment (see help). 
sndueste 59.1 1011 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
sndueste 14.1 1012
sndueste 59.1 1013
sndueste 79.1 1014 (% style="color:#ff6600" %)DBC2/error (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}(%%)
1015 //always saved (PBD)//
1016 (% style="color:#000000" %)E.bamError{{code language="none"}}DOOCS prop : FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIM{{/code}}(%%)
1017 (% style="color:#000000" %)FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.BAMERROR{{code language="none"}}DAQ channel: {{/code}}(%%)
sndueste 59.1 1018 desc: If the value is 0 , the BAM is working well. If it is non-zero there is a problem !!
1019
1020
sndueste 79.1 1021 (% style="color:#ff6600" %)DBC2/status  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}(%%)
1022 //always saved (PBD)//
1023 (% style="color:#000000" %)E..bamStatus.//2//{{code language="none"}}DOOCS prop : FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIM{{/code}}(%%)
1024 (% style="color:#000000" %): FLASH.SDIAG/BAM/FL0.DBC2/ARRIVAL_TIME.BAMSTATUS.2{{code language="none"}}DAQ channel{{/code}}(%%)
sndueste 59.1 1025 desc: status bit: 0 - data is valid; 1 - beam present; 2 - calibration ongoing; 3 - feedback enabled; 4 - feedback acting;  mostly check for bit 0 == 1 is sufficient
1026
1027
sndueste 68.1 1028 ====== **BAM FL2.SEED5**{{code language="none"}}{{/code}} ======
1029
sndueste 79.1 1030 /FL2/Electron Diagnostic/BAM/**SEED5**(% style="color:#ff6600" %)/electron bunch arrival time  (HDF5 name not yet implemented - see zraw)
sndueste 68.1 1031
sndueste 79.1 1032 (% style="color:#000000" %){{code language="none"}}/zraw/FLASH.SDIAG/BAM.DAQ/FL0.SEED5.ARRIVAL_TIME.ABSOLUTE.SA2.COMP/dGroup/{{/code}}
sndueste 73.1 1033
sndueste 68.1 1034 //always saved (PBD)//
sndueste 79.1 1035 (% style="color:#172b4d" %)**FL2.SEED5**(%%)
1036 (% style="color:#000000" %)channel: FLASH.SDIAG/BAM/(% style="color:#172b4d" %)**FL2.SEED5**(% style="color:#000000" %)/ARRIVAL_TIME.ABSOLUTE.SA1.COMP
sndueste 74.1 1037 {{code language="none"}} DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIME.ABSOLUTE.SA1.COMPDAQ {{/code}}(%%)desc: Electron bunch arrival time measured  with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020.. The property contains only the arrival time of the bunches sent to FL2 (e.g. if there are 30 bunches in FL2 the first 30 values are the arrival time the remaining numbers still may have arbitrary numbers looking like a signal which they are not). These are the same values as the "raw" data below - just "cleaned". The values show a very good correlation to the arrival time  of the XUV pulses in the experiment (see help).
sndueste 68.1 1038 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
1039
1040
1041
sndueste 79.1 1042 (% style="color:#172b4d" %)SEED5(% style="color:#ff6600" %)/electron bunch arrival time (raw) (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}
sndueste 73.1 1043
sndueste 79.1 1044 (% style="color:#000000" %){{code language="none"}}/zraw/FLASH.SDIAG/BAM.DAQ/FL0.SEED5.ARRIVAL_TIME.ABSOLUTE.SA2/dGroup/{{/code}}(%%)
1045 //always saved (PBD)//
1046 (% style="color:#172b4d" %)**FL2.SEED5**{{code language="none"}}DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIME.ABSOLUTE{{/code}}(%%)
1047 **~ **(% style="color:#000000" %)FLASH.SDIAG/BAM/(% style="color:#172b4d" %)**FL2.SEED5**(% style="color:#000000" %)/ARRIVAL_TIME.ABSOLUTE {{code language="none"}}DAQ channel:{{/code}}(%%)
sndueste 68.1 1048 desc: Electron bunch arrival time measured  with the BAM  before the undulator (pulse resolved data). This one was newly installed in 2020. Here the complete bunch train from the FEL is recorded (FLASH1 and FLASH2 pulses). Thus there are values from FLASH 2 in the second part. they may be separated by several "0" values if the reprate is different from 1 MHz ...  - It shows a very good correlation to the arrival time  of the XUV pulses in the experiment (see help). 
sndueste 59.1 1049 units: fs (bigger numbers (typically) indicate later arrival times of the electrons).
1050
1051
sndueste 79.1 1052 (% style="color:#172b4d" %)SEED5(% style="color:#ff6600" %)/error (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}(%%)
1053 //always saved (PBD)//
1054 (% style="color:#172b4d" %)**FL2.SEED5**(% style="color:#000000" %)E.bamError{{code language="none"}}DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIM{{/code}}(%%)
1055 (% style="color:#000000" %): FLASH.SDIAG/BAM/(% style="color:#172b4d" %)**FL2.SEED5**(% style="color:#000000" %)/ARRIVAL_TIME.BAMERROR{{code language="none"}}DAQ channel{{/code}}(%%)
sndueste 59.1 1056 desc: If the value is 0 , the BAM is working well. If it is non-zero there is a problem !!
1057
1058
sndueste 79.1 1059 (% style="color:#172b4d" %)SEED5(% style="color:#ff6600" %)/status  (HDF5 name not yet implemented - see zraw){{code language="none"}}/FL2/Electron Diagnostic/BAM/{{/code}}(%%)
1060 //always saved (PBD)//
1061 (% style="color:#172b4d" %)**FL2.SEED5**(% style="color:#000000" %)E.bamStatus.//2//{{code language="none"}}DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIM{{/code}}(%%)
1062 (% style="color:#000000" %)el: FLASH.SDIAG/BAM/(% style="color:#172b4d" %)**FL2.SEED5**(% style="color:#000000" %)/ARRIVAL_TIME.BAMSTATUS.2{{code language="none"}}DAQ chann{{/code}}(%%)
sndueste 59.1 1063 desc: status bit: 0 - data is valid; 1 - beam present; 2 - calibration ongoing; 3 - feedback enabled; 4 - feedback acting;  mostly check for bit 0 == 1 is sufficient
1064
1065
sndueste 15.1 1066 [[Contents>>doc:||anchor="Contents"]]
sndueste 12.1 1067
1068
sndueste 16.1 1069 ==== Timing information, rep rate etc.  (FLASH2) ====
sndueste 12.1 1070
sndueste 15.1 1071 ===== start time of FLASH2 =====
sndueste 12.1 1072
sndueste 79.1 1073 {{code language="none"}}/FL2/Timing/start time flash2{{/code}}
1074 //always saved (PBD2)//
1075 DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/BUNCH_POSITION.2{{/code}}
1076 DAQ channel: {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/BUNCH_POSITION.2{{/code}}
sndueste 17.1 1077 desc: The max 600 µs acceleration time of FLASH is devided between FLASH1 and FLASH2. This 600 µs window starts with FLASH1 (up to now)  at a time"label" of 700 µs (for historic reasons). Thus the first bunch of FLASH 1 comes at "700" and the last possibel bunch comes at 1300 (700+600). After FLASH1 train is over ther is a about 70µs switching time with no bunches. Then comes the first FLASH2 bunch.  Thus if e.g. the start time of FLASH2 is 1200 it means that FLASH2 starts at column 500 (1200-700)  in the HDF5 files. (However for yet unknown reasons this may change by 2-3 colums ...)
sndueste 15.1 1078 units: µs
sndueste 12.1 1079
1080 ===== bunch repetition rate =====
1081
sndueste 79.1 1082 {{code language="none"}}/FL2/Timing/repetition rate{{/code}}
1083 //always saved (PBD2)//
1084 DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/REP_RATE_KHZ.2{{/code}}
1085 DAQ channel: {{code language="none"}}FLASH.DIAG/TIMER/FLASHCPUTIME1.0/REP_RATE_KHZ.2{{/code}}
sndueste 15.1 1086 desc: repetition rate of the bunches / pulses within the burst (FLASH2)
sndueste 12.1 1087 units: kHz
1088
sndueste 74.1 1089
1090 ===== set number of pulses =====
1091
sndueste 79.1 1092 (% style="color:#ff6600" %)(HDF5 name not yet implemented - see zraw)(% style="color:#ff0000" %){{code language="none"}}/FL2/Timing/set number of bunches {{/code}}(%%)
1093 //always saved (PBD2)//
sndueste 74.1 1094 DOOCS prop : {{code language="none"}}FLASH.DIAG/TIMINGINFO/TIME1.BUNCH_FIRST_INDEX.2 [4th number]{{/code}}
1095 DAQ channel: {{code language="none"}}FLASH.DIAG/TIMINGINFO/TIME1.BUNCH_FIRST_INDEX.2 [4th number]{{/code}}
1096 desc: Number of bunches set in the control (timing) system.  The property contains 4 numbers. the last one is the number of pulses (see also [[doc:FLASH.Timing properties]] (internal link)).  If pulses are used for diagnostic of the protection system of the accelerator limits the number of bunches to be accelerated and thus the actual number of pulses may be smaller than the set one 
1097 units:
1098
sndueste 12.1 1099 ===== actual number of pulses =====
1100
sndueste 79.1 1101 {{code language="none"}}/FL1/Timing/actual number of bunches{{/code}}
1102 //always saved (PBD2)//
1103 DOOCS prop : {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/3GUN/NUMBEROFBUNCHES.FLASH2{{/code}}
1104 DAQ channel: {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/3GUN/NUMBEROFBUNCHES.FLASH2{{/code}}
1105 desc: Number of bunches measured BEHIND the undulator. If pulses are used for diagnostic of the protection system of the accelerator limits the number of bunches to be accelerated this is the actual number that created XUV radiation.The number is calculated by the DAQ middle layer server, (FLASH2)
sndueste 12.1 1106 units:
sndueste 79.1 1107
sndueste 12.1 1108
1109 ===== actual pulse pattern recorded after the undulator =====
1110
sndueste 79.1 1111 {{code language="none"}}/FL1/Timing/Bunch pattern/pattern after undulator{{/code}}
1112 //always saved (PBD2)//
1113 DOOCS prop : {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN.PULSEPATTERN{{/code}}
1114 DAQ channel: {{code language="none"}}FLASH.DIAG/PBD2.TOROID.ML/9FL2BURN.PULSEPATTERN{{/code}}
1115 desc: The bunch pattern as function of time in a burst recorded by toroide diagnostic BEHIND the undulator. (FLASH2)
sndueste 12.1 1116 units:
sndueste 79.1 1117
sndueste 12.1 1118
1119 ===== Train ID =====
1120
sndueste 79.1 1121 {{code language="none"}}/Timing/train ID{{/code}}
1122 //always saved (PBD2)//
1123 DOOCS prop : {{code language="none"}}none{{/code}}
1124 DAQ channel: {{code language="none"}}none{{/code}}
1125 desc: Each 10 Hz burst has its unique train ID. For the HDF5 dataset the ID is the same for all parameters with the same index (note camera images may be shifted by 1 ID - talk to the experts !)
sndueste 12.1 1126 units:
sndueste 79.1 1127
sndueste 12.1 1128
1129 ===== Train time =====
1130
sndueste 79.1 1131 //always saved (PBD2)//
1132 {{code language="none"}}/Timing/train time{{/code}}
1133 desc:Local time as array of day, hour, minute, second, and centisecond. This dataset is meant for visualisation purposes only. For correlations use the train ID or the Unix time of the time stamp
sndueste 12.1 1134 units: d h min s cs
sndueste 79.1 1135
sndueste 12.1 1136
sndueste 79.1 1137 {{code language="none"}}
1138 /Timing/time stamp
1139 {{/code}}
sndueste 16.1 1140
sndueste 79.1 1141 //always saved (PBD2)//
1142 desc: first column: Local time in unix time. To get day, hour, minute, second you can use unix: e.g. date ~-~-date='@1553617729' or matlab, python etc
1143 second column: microseconds
sndueste 12.1 1144 third column: Train ID of FLASH
sndueste 79.1 1145
sndueste 12.1 1146
1147 [[Contents>>doc:||anchor="Contents"]]
1148
1149
sndueste 19.1 1150 ==== User Data (FLASH2) ====
sndueste 18.1 1151
sndueste 19.1 1152 The data saved specifically for detectors at an experiment will show up in /Experiment/ there is a large number of options for cameras or monitoring pslow properties (motor positons etc) for user experiments. For details please ask your local contact.
1153
1154 NOTE: If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with the DOOCS names
1155
1156 The most common and permanently installed device used by experiment are our ADCs:
1157
sndueste 18.1 1158 ===== GHz ADCs =====
1159
sndueste 79.1 1160 ADC traces of the (SPDevices 412) GHZ ADCs available for the users . More information about the ADCs can be found** [[here>>doc:FLASHUSER.Data Acquisition and controls.Controls (DOOCS, jDDD,\.\.\.).MTCA ADCs.WebHome]]**
1161 //saved on DEMAND in the user DAQ//
sndueste 19.1 1162 \\Up to now there are 4 channels available at FL24
1163 \\\\{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD{{/code}}
1164 {{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH01/TD{{/code}}
1165 \\{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH02/TD{{/code}}{{code language="none"}}/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH03/TD{{/code}}
sndueste 18.1 1166
1167
sndueste 79.1 1168 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
sndueste 18.1 1169 here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} conatins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is used preferablly.
sndueste 19.1 1170 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.FL2EXP1/FL2EXP1.CH00{{/code}}
sndueste 18.1 1171
1172 In addition there are also additional parameters saved like:
1173
1174 * {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains.
1175 * {{code language="none"}}number of samples{{/code}}: total number of samoles recorded for each 10 Hz trigger
sndueste 79.1 1176 * {{code language="none"}}error (ADC):{{/code}}0 indicates that there was no error
sndueste 18.1 1177 * {{code language="none"}}/CH0-CH3/offset{{/code}}: To use the full dynamic range of the ADC one can shift the base line . This offset is saved here.
1178
1179 ===== MHz ADCs =====
1180
sndueste 79.1 1181 similar to the GHz ADCs the MHz ADCs are saved with HDF5 names like:
1182 {{code language="none"}}/FL2/Experiment/MTCA-EXP1/SIS8300 100MHz ADC/CH2/TD{{/code}}
1183 DOOCS prop : FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH02/CH00.TD
sndueste 19.1 1184 DAQ channel: : FLASH.FEL/ADC.SIS.FL2EXP1/FL2EXP1.CH02
sndueste 18.1 1185
1186 In addition there are also additional parameters saved like:
1187
1188 * {{code language="none"}}sample frequency{{/code}}: it shows the sample frequency in MHz (number of samples per µs). NOTE: the clock of the ADC is NOT synchronized to the FLASH timing system. Thus the number of samples between bunches in the bunch train may be not integer numbers which will be show up for long bunch trains.
1189 * {{code language="none"}}number of samples{{/code}}: total number of samoles recorded for each 10 Hz trigger
1190
1191 [[Contents>>doc:||anchor="Contents"]]
1192
sndueste 12.1 1193
1194
sndueste 77.1 1195 ==== FL 24 Pump Probe Laser (FLASH2) ====
sndueste 21.1 1196
sndueste 80.1 1197 {{info}}
1198 list of saved parameters status May 2024 (up to now the parameters can be found in /zraw/ ... )
1199
1200 [[attach:FSLADAQ-FL23.pdf||target="_blank"]]
1201
1202 [[attach:FSLADAQ-DAQParameterlistFL24.pdf||target="_blank"]]
1203
1204 [[attach:FSLADAQ-DAQParameterlistPPlaser.pdf||target="_blank"]]
1205 {{/info}}
1206
1207
sndueste 79.1 1208 These are the parameters that can be saved in the FL2 User DAQ for the FL2 PP laser//** FOR BEAMLINE FL24**//
sndueste 21.1 1209
sndueste 64.1 1210 **User delay**
1211
1212 Delay (set value):
1213
sndueste 79.1 1214 {{code language="none"}}
1215 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.POSITION_SET.WR
1216 {{/code}}
sndueste 64.1 1217
sndueste 77.1 1218 Delay (readback):
sndueste 64.1 1219
sndueste 79.1 1220 {{code language="none"}}
1221 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.POSITION.RD
1222 {{/code}}
sndueste 64.1 1223
sndueste 79.1 1224 (% style="letter-spacing:0.0px" %)Delay (encoder readback):
sndueste 77.1 1225
sndueste 79.1 1226 {{code language="none"}}
1227 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.ENCODER_POSITION.RD
1228 {{/code}}
sndueste 77.1 1229
sndueste 64.1 1230 OXC. jitter:
1231
sndueste 79.1 1232 {{code language="none"}}
1233 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/CURRENT_INPUT_JITTER.RD
1234 {{/code}}
sndueste 64.1 1235
1236
1237
sndueste 77.1 1238 **FL24 Pulse resolved energy:**
1239
sndueste 72.1 1240 OPCPA output (photodiode signal raw ADC trace 16000 samples):
sndueste 64.1 1241
sndueste 79.1 1242 {{code language="none"}}
1243 /zraw/FLASH.LASER/FLASH2CPUULGAN1.ADCSCOPE/CH23.TD/dGroup
1244 {{/code}}
sndueste 64.1 1245
sndueste 79.1 1246 (% style="letter-spacing:0.0px" %)Upper breadboard Photodiode (THG) burst (photodiode signal raw ADC trace 16000 samples)::
sndueste 64.1 1247
sndueste 79.1 1248 {{code language="none"}}
1249 /zraw/FLASH.LASER/FLASH2CPUULGAN1.ADCSCOPE/CH26.TD/dGroup
1250 {{/code}}
sndueste 64.1 1251
sndueste 72.1 1252 Upper breadboard Photodiode (THG) energy (analyzed signal. integration over pulses in the ADC trace. contains for each laser pulse the pulse energy in a.u.)
sndueste 64.1 1253
sndueste 79.1 1254 {{code language="none"}}
1255 /zraw/FLASH.LASER/MOD24.PES/FL24_userPD/dGroup
1256 {{/code}}
sndueste 64.1 1257
1258
sndueste 77.1 1259 **FL24 LAM (Laser Arrivaltime Monitor)  pulse resolved data:**
sndueste 64.1 1260
sndueste 72.1 1261 Signal of Photodiode1  - for experts only... (analyzed signal. integration over pulses in the ADC trace. )
1262
sndueste 79.1 1263 {{code language="none"}}
1264 /zraw/FLASH.LASER/MOD24.PES/LAM.PD1/dGroup
1265 {{/code}}
sndueste 72.1 1266
1267 Signal of Photodiode2  - for experts only...  (analyzed signal. integration over pulses in the ADC trace.)
1268
sndueste 79.1 1269 {{code language="none"}}
1270 /zraw/FLASH.LASER/MOD24.PES/LAM.PD2/dGroup
1271 {{/code}}
sndueste 72.1 1272
1273 "Actual" LAM Signal - to be calibrated ......  (analyzed signal. integration over pulses in the ADC trace.)
1274
sndueste 79.1 1275 {{code language="none"}}
1276 /zraw/FLASH.LASER/MOD24.PES/LAM.PDBAL/dGroup
1277 {{/code}}
sndueste 72.1 1278
sndueste 79.1 1279 The delay feedback(% style="letter-spacing:0.0px" %)
sndueste 75.1 1280
sndueste 79.1 1281 {{code language="none"}}
1282 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.DOUBLES/DOUBLE26 
1283 {{/code}}
sndueste 64.1 1284
sndueste 79.1 1285 The LAM delay feedback(% style="letter-spacing:0.0px" %) (the pulse energy signal, which is saved in the above but maybe it’s good to have this also as slow, in the case these two numbers are not the same the sysdc was active instead of the LAM):
sndueste 75.1 1286
sndueste 79.1 1287 {{code language="none"}}
1288 FLASH.LASER/MOD24.PES/LAM.PDBAL/PULSEENERGY.MEAN
1289 {{/code}}
sndueste 75.1 1290
sndueste 76.1 1291 LAM Delay line act:
sndueste 75.1 1292
sndueste 76.1 1293 {{code language="none"}}FLASH.SYNC/LAM.EXP.ODL/F2.MOD.AMC12/FMC0.MD22.1.POSITION.RD{{/code}}
1294 LAM Delay line set:
sndueste 75.1 1295
sndueste 79.1 1296 {{code language="none"}}
1297 FLASH.SYNC/LAM.EXP.ODL/F2.MOD.AMC12/FMC0.MD22.1.POSITION_SET.WR
1298 {{/code}}
sndueste 75.1 1299
sndueste 76.1 1300 LAM Delay line encoder:
sndueste 75.1 1301
sndueste 79.1 1302 {{code language="none"}}
1303 FLASH.SYNC/LAM.EXP.ODL/F2.MOD.AMC12/FMC0.MD22.1.ENCODER_POSITION.RD
1304 {{/code}}
sndueste 75.1 1305
sndueste 76.1 1306 Temperature feedback:
sndueste 75.1 1307
sndueste 79.1 1308 {{code language="none"}}
1309 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.DOUBLES/DOUBLE24
1310 {{/code}}
sndueste 75.1 1311
1312 **Feedback mode** (if this is not =1 the delay FB is not active, then it’s either temp feedback controlled or failsave, maybe it’s good to have):
1313
sndueste 79.1 1314 {{code language="none"}}
1315 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.INTS/INTEGER30
1316 {{/code}}
sndueste 75.1 1317
1318
sndueste 77.1 1319 **FL24 Attenuator angle:**
sndueste 75.1 1320
sndueste 79.1 1321 {{code language="none"}}
1322 FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS
1323 {{/code}}
sndueste 64.1 1324
sndueste 77.1 1325 **FL24 Polarization control:**
sndueste 64.1 1326
sndueste 79.1 1327 {{code language="none"}}
1328 FLASH.FEL/FLAPP2BEAMLINES/MOTOR14.FL24/FPOS
1329 {{/code}}
sndueste 64.1 1330
1331 **SysDC delay error:**
1332
sndueste 79.1 1333 {{code language="none"}}
1334 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.DOUBLES/DOUBLE26
1335 {{/code}}
sndueste 64.1 1336
1337
1338 **Timing error: (these two need to be observed and both=0 means no error)**
1339
sndueste 79.1 1340 {{code language="none"}}
1341 FLASH/CPUULGAN1.TIMING/ULGAN1/dT_alarm
1342 {{/code}}
sndueste 64.1 1343
sndueste 79.1 1344 {{code language="none"}}
1345 FLASH/CPUULGAN1.TIMING/ULGAN1/dMPN
1346 {{/code}}
sndueste 64.1 1347
1348 **Laser error status:**
1349
1350
sndueste 77.1 1351 **FL24 Virtual camera X and Y history, beam size: (use slow data)**
sndueste 64.1 1352
sndueste 79.1 1353 {{code language="none"}}
1354 FLASH.LASER/MOD24.BEAMPOS/UV.VF_BP/CENTER.X
1355 {{/code}}
sndueste 64.1 1356
sndueste 79.1 1357 {{code language="none"}}
1358 FLASH.LASER/MOD24.BEAMPOS/UV.VF_BP/CENTER.Y
1359 {{/code}}
sndueste 64.1 1360
sndueste 79.1 1361 {{code language="none"}}
1362 FLASH.LASER/MOD24.CAM/UV.14.VF/ROI_SPECTRUM.X.SIG
1363 {{/code}}
sndueste 64.1 1364
1365 {{expand title="Parameters used until 2021"}}
sndueste 79.1 1366 //{{code language="none"}}/FL2/Experiment/Pump probe laser/FL24/attenuator position{{/code}}always saved (PBD2)//
1367 DOOCS prop : {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS{{/code}}
1368 DAQ channel: {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR1.FL24/FPOS{{/code}}
1369 desc: attenuation of the PPLaser in the FL24 hutch (rotation of a waveplate)
sndueste 21.1 1370 units : deg.
1371
sndueste 12.1 1372
sndueste 21.1 1373
sndueste 79.1 1374 //{{code language="none"}}/FL2/Experiment/Pump probe laser/FL24/polarization position{{/code}}always saved (PBD2)//
1375 DOOCS prop : {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/FPOS{{/code}}
1376 DAQ channel: {{code language="none"}}FLASH.FEL/FLAPP2BEAMLINES/MOTOR2.FL24/FPOS{{/code}}
1377 desc: attenuation of the PPLaser in the FL24 hutch (rotation of a waveplate)
sndueste 21.1 1378 units : deg.
1379
sndueste 12.1 1380
sndueste 79.1 1381 {{code language="none"}}/FL1/Experiment/Pump probe laser/laser delay readback{{/code}}
1382 //always saved (PBD2)//
1383 DOOCS prop : {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD{{/code}}
sndueste 21.1 1384 DAQ channel: {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/FMC0.MD22.0.POSITION.RD{{/code}}
1385 desc: delay of the Pump probe laser - measured by the read back position of the motor. There is also the set value available ( upto now these values are only updating every 1-2 seconds. There is no fast encoder property as on FLASH1 available)
1386 units : ps )
1387
sndueste 12.1 1388
sndueste 79.1 1389 {{code language="none"}}/FL1/Experiment/Pump probe laser/Synchronization/timing jitter RMS{{/code}}
1390 //always saved (PBD)//
1391 DOOCS prop : {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD{{/code}}
1392 DAQ channel: {{code language="none"}}FLASH.SYNC/LASER.LOCK.EXP/FLASH2.PPL1.OSC1/CURRENT_INPUT_JITTER.RD{{/code}}
sndueste 22.1 1393 desc: rms jitter of the fs-Oscillator
1394 units: fs
sndueste 65.1 1395 {{/expand}}
sndueste 21.1 1396
sndueste 77.1 1397
1398 ==== FL 26 Pump Probe Laser (FLASH2) ====
1399
sndueste 79.1 1400 These are the parameters that can be saved in the FL2 User DAQ for the FL2 PP laser//** FOR BEAMLINE FL26**//
sndueste 77.1 1401
1402
1403 **User delay**
1404
1405 Delay (set value):
1406
sndueste 79.1 1407 {{code language="none"}}
1408 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.POSITION_SET.WR
1409 {{/code}}
sndueste 77.1 1410
1411 Delay (readback):
1412
sndueste 79.1 1413 {{code language="none"}}
1414 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.POSITION.RD
1415 {{/code}}
sndueste 77.1 1416
sndueste 78.1 1417 Delay (encoder readback):
sndueste 77.1 1418
sndueste 79.1 1419 {{code language="none"}}
1420 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.ENCODER_POSITION.RD
1421 {{/code}}
sndueste 77.1 1422
1423 OXC. jitter:
1424
sndueste 79.1 1425 {{code language="none"}}
1426 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/CURRENT_INPUT_JITTER.RD
1427 {{/code}}
sndueste 77.1 1428
1429
1430 **Parameters for FL26**
1431
sndueste 78.1 1432 (% class="wrapped" %)
sndueste 77.1 1433 |(((
1434 FL2PPL FL26 REMI Attenuation: HWP motor current position
1435 )))|(((
1436 FLASH.FEL/FLAPP2BEAMLINES/MOTOR11.FL26B/FPOS
1437 )))
1438 |(((
1439 FL2PPL FL26 REMI Polarization: linear polarization angle
1440 )))|(((
1441 FLASH.FEL/FLAPP2BEAMLINES/MOTOR12.FL26B/FPOS
1442 )))
1443 |(((
1444 FL2PPL FL26 REMI Diagnostics: NIR spectrum
1445 )))|(((
1446 FLASH.LASER/MOD26.SPECT/REMI/DAQ_CHANNEL
1447 )))
1448 |(((
1449 FL2PPL FL26 REMI Diagnostics: photo diode input MOD2.6 - pulse energy mean
1450 )))|(((
1451 FLASH.LASER/MOD26.PES/RE_OUT/PULSEENERGY.MEAN
1452 )))
1453 |(((
1454 FL2PPL FL26 REMI Diagnostics: photo diode input MOD2.6 - intra burst pulse energy
1455 )))|(((
1456 FLASH.LASER/MOD26.PES/RE_OUT/DAQ_CHANNEL
1457 )))
1458 |(((
1459 FL2PPL FL26 REMI Diagnostics: photo diode input MOD2.6 - raw adc
1460 )))|(((
1461 FLASH.LASER/TAMC532DMA/ULGAN1_S5/CH04.TD
1462 )))
1463 |(((
1464 FL2PPL FL26 REMI Diagnostics: photo diode input REMI - pulse energy mean
1465 )))|(((
1466 FLASH.LASER/MOD26.PES/INC_BOX/PULSEENERGY.MEAN
1467 )))
1468 |(((
1469 FL2PPL FL26 REMI Diagnostics: photo diode input REMI - intra burst pulse energy
1470 )))|(((
1471 FLASH.LASER/MOD26.PES/INC_BOX/DAQ_CHANNEL
1472 )))
1473 |(((
1474 FL2PPL FL26 REMI Diagnostics: photo diode input REMI - raw adc
1475 )))|(((
1476 FLASH.LASER/TAMC532DMA/ULGAN1_S5/CH05.TD
1477 )))
1478 |(((
1479 FL2PPL FL26 REMI In coupling: filter wheel 1 position
1480 )))|(((
1481 FLASH/MOD26.FW1/FLASH2MOD26/pos
1482 )))
1483 |(((
1484 FL2PPL FL26 REMI In coupling: filter wheel 2 position
1485 )))|(((
1486 FLASH/MOD26.FW2/FLASH2MOD26/pos
1487 )))
1488 |(((
1489 FL2PPL FL26 REMI: Energy meter REMI incoupling breadboard
1490 )))|(((
1491 FLASH.LASER/MOD26.OPHIRE/REINC.54/DAQ_CHANNEL
1492 )))
1493 |(((
1494 FL2PPL FL26 REMI Incoupling: focusing lens position
1495 )))|(((
1496 FLASH.FEL/FLAPP2BEAMLINES/MOTOR3.FL26B/FPOS
1497 )))
1498 |(((
1499 FL2PPL FL26 REMI Incoupling: nearfield
1500 )))|(((
1501 FLASH.LASER/MOD26.CAM/REINC.21.NF/DAQ_CHANNEL
1502 )))
1503 |(((
1504 FL2PPL FL26 REMI Incoupling: focus
1505 )))|(((
1506 FLASH.LASER/MOD26.CAM/REINC.22.FF/DAQ_CHANNEL
1507 )))
1508 |(((
1509 FL2PPL FL26 REMI Drift: relative arrival time intra burst LAM balanced - calb. in the PES
1510 )))|(((
1511 FLASH.LASER/MOD26.PES/LAM_DIFF/DAQ_CHANNEL
1512 )))
1513 |(((
1514 FL2PPL FL26 REMI Drift: forward signal (PD1)  raw
1515 )))|(((
1516 FLASH.LASER/TAMC532DMA/ULGAN1_S5/CH00.TD
1517 )))
1518 |(((
1519 FL2PPL FL26 REMI Drift: backward signal (PD2) raw
1520 )))|(((
1521 FLASH.LASER/TAMC532DMA/ULGAN1_S5/CH01.TD
1522 )))
1523 |(((
1524 FL2PPL FL26 REMI Drift: mean relative burst arrival time - avarage of the calib value
1525 )))|(((
1526 FLASH.LASER/MOD26.PES/LAM_DIFF/PULSEENERGY.MEAN
1527 )))
1528 |(((
1529 FL2PPL FL26 REMI Drift: delay line position (ODL of the LAM REMI)
1530 )))|(((
1531 FLASH.FEL/FLAPP2BEAMLINES/MOTOR14.FL26B/FPOS
1532 )))
1533 |(((
1534 FL2PPL FL26 Laser Hutch: delay line position (ODL of the osc. Sync / user delay)
1535 )))|(((
1536 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/FMC0.MD22.0.POSITION.RD
1537 )))
1538 |(((
1539 FL2PPL FL26 REMI Drift: delay line encoder position (ODL REMI raw value)
1540 )))|(((
1541 FLASH.SYNC/LAM.EXP.ODL/F2.MOD.AMC12/FMC0.MD22.0.ENCODER_POSITION.RD
1542 )))
1543 |(((
1544 Jiiter between oscillator and MLO (inloop jitter osc. Sync)
1545 )))|(((
1546 FLASH.SYNC/LASER.LOCK.EXP/F2.PPL.OSC/CURRENT_INPUT_JITTER.RD
1547 )))
1548 |(((
1549 Temperature controlled fiber (PWM signal to the temperature controlled fiber delay sysdc)
1550 )))|(((
1551 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.DOUBLES/DOUBLE23
1552 )))
1553 |(((
1554 Temperature controlled fiber (Temp of the fiber delay sysdc)
1555 )))|(((
1556 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.DOUBLES/DOUBLE24
1557 )))
1558 |(((
1559 Sydc feedback data if LAM is not activated (sysdc delay)
1560 )))|(((
1561 FLASH.LASER/ULGAN1.DYNPROP/TCFIBER.DOUBLES/DOUBLE26
1562 )))
1563
sndueste 21.1 1564 [[Contents>>doc:||anchor="Contents"]]
1565
1566
sndueste 23.1 1567 === "/uncategorized/" ===
1568
1569 If parameters for an experiment are included on short notice the correct naming in the HDF5 may not be in time and the data will show up in /uncategorized/ with their DOOCS names
1570
1571
sendels 1.1 1572 === HDF5 structure revisions ===
1573
1574 Starting with Beamblock 4, August 2018, the hierarchy of the HDF group names have been adapted to reflect the new situation at FLASH. FLASH2 is operating for users quite some time now. Therefore, both accelerators appear equally in their respective HDF groups, namely "/FL1" and "/FL2". The root group of proper, by run organised HDF files have an attribute called "version". This version attribute has changed from "0.2.x" to "0.3.x". The changes in detail:
1575
1576
1577 * All FLASH1 related HDF groups moved to group "/FL1", i.e. a new prefix "/FL1" is added to their HDF path.
1578 * The ambigious term "pulse" has been replaced by "train" to refer to "pulse train". Most notably, the dataset "/Timing/pulse ID" has changed to "/Timing/train ID".
1579 * A number of inconsistent names have been streamlined. The relevant changes are listed in the following table.
1580
sndueste 45.1 1581 (% class="wrapped" %)
sendels 1.1 1582 |=(((
sendels 4.1 1583 earlier HDF path (vers. 0.2)
sendels 1.1 1584 )))|=(((
sendels 4.1 1585 is now (vers. 0.3)
sendels 1.1 1586 )))
1587 |(((
1588 /Photon Diagnostic/GMD/Beam position/position BDA x
1589 )))|(((
1590 /FL1/Photon Diagnostic/GMD/Beam position/position BDA horizontal
1591 )))
1592 |(((
1593 /Photon Diagnostic/GMD/Beam position/position BDA y
1594 )))|(((
1595 /FL1/Photon Diagnostic/GMD/Beam position/position BDA vertical
1596 )))
1597 |(((
1598 /Photon Diagnostic/GMD/Beam position/position tunnel x
1599 )))|(((
1600 /FL1/Photon Diagnostic/GMD/Beam position/position tunnel horizontal
1601 )))
1602 |(((
1603 /Photon Diagnostic/GMD/Beam position/position tunnel y
1604 )))|(((
1605 /FL1/Photon Diagnostic/GMD/Beam position/position tunnel vertical
1606 )))
1607 |(((
1608 /Experiment/Pump probe laser/BPM/position x
1609 )))|(((
1610 /FL1/Experiment/Pump probe laser/BPM/position horizontal
1611 )))
1612 |(((
1613 /Experiment/Pump probe laser/BPM/position y
1614 )))|(((
1615 /FL1/Experiment/Pump probe laser/BPM/position vertical
1616 )))
1617 |(((
1618 /FL2/Photon Diagnostic/GMD/Beam position/Average/position hall horizontal
1619 )))|(((
1620 /FL2/Photon Diagnostic/GMD/Average beam position/position hall horizontal
1621 )))
1622 |(((
1623 /FL2/Photon Diagnostic/GMD/Beam position/Average/position hall vertical
1624 )))|(((
1625 /FL2/Photon Diagnostic/GMD/Average beam position/position hall vertical
1626 )))
1627 |(((
1628 /FL2/Photon Diagnostic/GMD/Beam position/Average/position tunnel horizontal
1629 )))|(((
1630 /FL2/Photon Diagnostic/GMD/Average beam position/position tunnel horizontal
1631 )))
1632 |(((
1633 /FL2/Photon Diagnostic/GMD/Beam position/Average/position tunnel vertical
1634 )))|(((
1635 /FL2/Photon Diagnostic/GMD/Average beam position/position tunnel vertical
1636 )))
1637 |(((
1638 /FL2/Photon Diagnostic/GMD/Average energy/hall
1639 )))|(((
1640 /FL2/Photon Diagnostic/GMD/Average energy/energy hall
1641 )))
1642 |(((
1643 /FL2/Photon Diagnostic/GMD/Average energy/hall (raw)
1644 )))|(((
1645 /FL2/Photon Diagnostic/GMD/Average energy/energy hall (raw)
1646 )))
1647 |(((
1648 /FL2/Photon Diagnostic/GMD/Average energy/tunnel
1649 )))|(((
1650 /FL2/Photon Diagnostic/GMD/Average energy/energy tunnel
1651 )))
1652 |(((
1653 /FL2/Photon Diagnostic/GMD/Average energy/tunnel (raw)
1654 )))|(((
1655 /FL2/Photon Diagnostic/GMD/Average energy/energy tunnel (raw)
1656 )))
1657 |(((
1658 /FL2/Photon Diagnostic/GMD/Beam position/Pulse resolved/hall x
1659 )))|(((
1660 /FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position hall horizontal
1661 )))
1662 |(((
1663 /FL2/Photon Diagnostic/GMD/Beam position/Pulse resolved/hall y
1664 )))|(((
1665 /FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position hall vertical
1666 )))
1667 |(((
1668 /FL2/Photon Diagnostic/GMD/Beam position/Pulse resolved/tunnel x
1669 )))|(((
1670 /FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel horizontal
1671 )))
1672 |(((
1673 /FL2/Photon Diagnostic/GMD/Beam position/Pulse resolved/tunnel y
1674 )))|(((
1675 /FL2/Photon Diagnostic/GMD/Pulse resolved beam position/position tunnel vertical
1676 )))
1677
sendels 4.1 1678 [[Contents>>doc:||anchor="Contents"]]
sendels 1.1 1679
sndueste 79.1 1680
cpassow 44.1 1681 {{/layout-cell}}
1682 {{/layout-section}}
1683 {{/layout}}