Changes for page Gotthard related stuff
Last modified by sndueste on 2025-08-22 10:41
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 11 added, 0 removed)
- 20230922_161707_resized.jpg
- Clipboard01.gif
- Clipboard05.gif
- FLASH-GH-Meeting_10.10.2014.pdf
- Flash_G1.pdf
- GOTTHARD noise evaluation and exposure time dependence (002).pdf
- MP-E_65mm_F2.8_1-5x_Instruction_DE.pdf
- READ_ME_GOTTHARD_detector.pdf
- cfeld-gotthard02.jpg
- hasdslabgh.jpg
- image2023-9-15_11-16-3.png
Details
- Page properties
-
- Parent
-
... ... @@ -1,0 +1,1 @@ 1 +FLASHUSER.Misc.jddd-linked help pages.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. palutke1 +XWiki.sndueste - Content
-
... ... @@ -1,16 +1,23 @@ 1 -== Info relatedtotheDetector==1 +== page content: == 2 2 3 - \\3 +{{toc maxLevel="2"/}} 4 4 5 + 6 +== Info collection related to the Detector == 7 + 5 5 * [[Data sheet of a macro objective>>attach:MP-E_65mm_F2.8_1-5x_Instruction_DE.pdf]] 6 6 * [[FLASH-GH-Meeting_10.10.2014.pdf by Steffen>>attach:FLASH-GH-Meeting_10.10.2014.pdf]] 7 7 * [[attach:READ_ME_GOTTHARD_detector.pdf]]: READ_ME_GOTTHARD_detector.pdf (Server information is outdated, see below) 11 +* some investigation related to read out noise for different exposure times [[attach:GOTTHARD noise evaluation and exposure time dependence (002).pdf]] 8 8 9 -\\ 10 10 11 -Ethernet connections: 12 12 13 -(% style="list-style-type: square;" %) 15 +Ethernet and trigger connections: 16 + 17 +[[image:attach:20230922_161707_resized.jpg||thumbnail="true" height="250"]] 18 + 19 +(% style="list-style-type:square" %) 20 +* trigger at port 1 14 14 * gbit port <~-~--> Server PC (hasfl2det01 at FLASH2, no server currently at FLASH1) 15 15 * base-T <~-~--> Office net 16 16 ... ... @@ -18,48 +18,50 @@ 18 18 19 19 for now very short: run the Exp2 DAQ with EXPERIMENT_GOTTHARD included as shown below. AND press the start button in the Gotthard DAQ (you get there from the Gotthard panel lower left button "Gotthard DAQ" 20 20 21 -\\ 22 22 23 23 * Main Gotthard panel for users : 24 24 25 25 [[image:attach:Clipboard05.gif||height="400"]] 26 - \\32 + 27 27 28 -\\ 29 29 30 30 * Exp2 DAQ RC gui for recording Gotthard data. EXPERIMENT_GOTTHARD has to be included 31 31 32 32 [[image:attach:Clipboard01.gif||height="400"]] 33 33 34 -\\ 35 35 40 + 36 36 == Operation hints (June 2023): == 37 37 38 -(% style="list-style-type: square;" %)43 +(% style="list-style-type:square" %) 39 39 * **Where is the GOTTHARD GUI:** FLASH2 - Panel: Infrastructure tab → Miscellaneous tab → FLASH2 GOTTHARD ctrl button 40 40 * **Never change a running system:** Do not change parameters while the Detector is running/taking data, The detector will crash. 41 41 * Furthermore the module will crash if recieving to much light (e.g. illuminating with flash light during data dating. 42 42 * **Checking/switching server:** The server is reachable from the GOTTHARD GUI (lower left corner find the status of the server PC "hasfl2det01") click it to open server/watchdog control. The server is otherwise found under FLASH.SYSTEM → HASFL2DET01.WATCH. Open control of SVR.GOTTHARD (for start/stop/reboot) 43 43 44 -(% style="list-style-type: square;" %)49 +(% style="list-style-type:square" %) 45 45 * **Robooting the GOTTHARD** (if it has crashed): 46 -(% style="list-style-type: square;" %)51 +(% style="list-style-type:square" %) 47 47 ** soft reboot: 1. open console on linux DESY PC, 2. type "telnet (Hostname/IP)" e.g. "telnet cfeld-gotthard02" , 3. you are logged on the GOTTHARD module as /root, type "reboot", 4. wait until server/GUI has reconnected to the module 48 48 ** hard reset: power down the GOTTHARD, wait some seconds, Repower the module, wait for reconnection to server/GUI 49 49 * **In case of a crashes** (no data taking, no reaction on input: Reboot the detector) or if GUI input returns error: Check connection (Power/Data), check GOTTHARD server 55 +* **Permantent operation:** Activate check box for continous run to trigger automated restart of the module after reaching the set number of short or after sefl-stopping due to hickups. The restart needs about 1-2 seconds. During this time no data is taken. 56 +* **Background**: Check "Take" stores the actual detector image~: Uncheck this again. Than this stored image is online subtracted from all images in the GUI when checking "subtract". The DAQ only stores raw data (NOT the background subtracted images) 50 50 51 51 Using burst mode (standard operation as of June 2023) 52 52 53 -(% style="list-style-type: square;" %)60 +(% style="list-style-type:square" %) 54 54 * Do not change the delay in the GOTTHARD GUI. The Alignment to the FEL pulses are done by adjusting the FLASH trigger: FL2EXP1/RTM.TRG6, it can be opened from the GOTTHARD GUI or from FLASH2 → Beamlines → FL26 → Exp. control → Patch Panel26-2 → MTCA Trigger 2 55 -* Exposure range is 100ns < Exposure < ~~1/3 * Frame periode 56 -* The periode is: 9968ns for 100kHz, 62 +* Exposure range is 2**00ns < Exposure < ~~1/3 * Frame periode** 63 +* The periode is:** 9968ns for 100kHz, 4984 for 200kHz, 1993 for 500kHz** 64 +* The number of** frames must be lower than 125, for stable operation 120** 65 +* Number of Shots: Number of trigger events before self stopping, select large number for permanent operation 57 57 58 58 == Modules and their exchange == 59 59 60 60 Two (Three) modules available (physically at FLASH): 61 61 62 -(% class=" wrapped relative-table" style="width:64.2451%;" %)71 +(% class="relative-table wrapped" style="width:64.2451%" %) 63 63 |=((( 64 64 hostname 65 65 )))|=((( ... ... @@ -70,6 +70,8 @@ 70 70 Sensor image 71 71 )))|=((( 72 72 config file 82 +)))|=(% colspan="1" %)((( 83 +DOOCS address (status 2023) 73 73 ))) 74 74 |((( 75 75 cfeld-gotthard02 ... ... @@ -87,9 +87,13 @@ 87 87 ))) 88 88 )))|((( 89 89 bchip_mpc1922Receiver.config_cfeld-gotthard02 101 +)))|(% colspan="1" %)((( 102 +FLASH.FEL/GOTTHARD/FL2/ 90 90 ))) 91 91 |((( 92 92 hasdslabgh 106 + 107 +"gotthard dgt01" 93 93 )))|((( 94 94 working 95 95 )))|((( ... ... @@ -101,6 +101,8 @@ 101 101 ))) 102 102 )))|((( 103 103 bchip_mpc1922Receiver.config 119 +)))|(% colspan="1" %)((( 120 +FLASH.FEL/GOTTHARD2/FL2/ 104 104 ))) 105 105 |((( 106 106 cfeld-gotthard01 ... ... @@ -109,22 +109,22 @@ 109 109 )))|((( 110 110 ? 111 111 )))|(% colspan="1" %)((( 112 - \\129 + 113 113 )))|((( 114 114 bchip_mpc1922Receiver_petra.config 132 +)))|(% colspan="1" %)((( 133 + 115 115 ))) 116 116 117 -\\ 118 118 137 + 119 119 To change a module the respective config file has to be selected. However changing it will crash the server, thus, it is not possible to change on the fly. Connact Sören if there is the need to exchange a module. However, the differences in the configs are only the hostname. (**To be tested: On the fly might work, if one edits the config-file itself after switching of the server instead of selecting another config file in the GUI. But how to transport this information to the GUI? → Display the first line of the config file!**) The config files are located at the **hasfl2det01: /export/doocs/server/gotthard_server/cfgs/** 120 120 121 -\\ 122 122 123 123 == GOTTHARD Server == 124 124 125 -The server for GOTTHARD (FLASH2) runs on **hasfl2det01**. Its watchdog and control (svr.GOTTHARD) can be found under** FLASH.SYSTEMS - HASFL2DET01.**143 +The server for GOTTHARD (FLASH2) runs on **hasfl2det01**. Its watchdog and control (svr.GOTTHARD) can be found under** FLASH.SYSTEMS - HASFL2DET01.** 126 126 127 -\\ 128 128 129 129 == Main Parameters and limits == 130 130 ... ... @@ -148,7 +148,7 @@ 148 148 )))|((( 149 149 ~~2/3 of period time 150 150 )))|(% colspan="1" %)((( 151 - \\168 + 152 152 ))) 153 153 |((( 154 154 Min. period time ... ... @@ -155,7 +155,7 @@ 155 155 )))|((( 156 156 ca. 930 ns 157 157 )))|(% colspan="1" %)((( 158 - \\175 + 159 159 ))) 160 160 |((( 161 161 Max repetition frequ. ... ... @@ -165,21 +165,21 @@ 165 165 833 kHz (software limited) 166 166 ))) 167 167 168 -\\ 169 169 186 + 170 170 == Soft reset a GOTTHARD Module == 171 171 172 -(% style="list-style-type: square;" %)189 +(% style="list-style-type:square" %) 173 173 * Open console on Linux PC (connected to DESY net) 174 174 * write "telnet cfeld-gotthard02" (or the respective Host name or IP of the module) 175 -(% style="list-style-type: square;" %)192 +(% style="list-style-type:square" %) 176 176 ** you should be connected to the GOTTHARD onboard system → </root: 177 177 * type: "reboot" 178 -(% style="list-style-type: square;" %)195 +(% style="list-style-type:square" %) 179 179 ** the module reboots (wait ~~1-2 min), the telnat connection will be cut due to reboot. 180 180 181 -\\ 182 182 199 + 183 183 == Triggering the Gotthard with a burst trigger == 184 184 185 185 it is also possible to trigger the Gotthard not only with 10 Hz but with a burst trigger ... ... @@ -204,7 +204,6 @@ 204 204 205 205 Alignment: One of the four lemo connectors on G1 outputs its exposure window. Using an oscilloscope, one can use a photodiode under the beam and align the pulses from the diode and the exposure window of G1 by fine tuning the exposure time of G1 and/or the setting of "delay after trigger" from the detector, or "delay time" of the wave-generator (if a wave-generator is used to generate the triggers for every pulse). After this, one can do a fine scan of trigger delay to find an optimal setting with highest signal after putting G1 under the beam. 206 206 207 -\\ 208 208 209 209 by: 210 210 ... ... @@ -218,6 +218,26 @@ 218 218 219 219 Switzerland 220 220 221 -\\ 222 222 223 -\\ 238 +== Using the Spectralyzer together with Gotthard == 239 + 240 +one needs spectralyzer 0.2.4 or newer 241 + 242 + 243 +start spectralyzer on one of our consoles ( works for fl24 and fl26user ) (for installing new version or for other users .. ask Christopher Behrens... ) 244 + 245 +(% class="code" %) 246 +((( 247 +fl26user@hasfcons1:~~$ mamba activate spectralyzer 248 +(spectralyzer) fl26user@hasfcons1:~~$ spectralyzer 249 +))) 250 + 251 + 252 +[[image:url:https://ttfinfo.desy.de/Flash2_FL26elog/data/2023/06/2023-02-10T16:03:53-00.jpg||height="250"]] 253 + 254 +[[image:attach:image2023-9-15_11-16-3.png||height="400"]] 255 + 256 + 257 + 258 + 259 +
- 20230922_161707_resized.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +735.8 KB - Content
- Clipboard01.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.5 KB - Content
- Clipboard05.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +251.7 KB - Content
- FLASH-GH-Meeting_10.10.2014.pdf
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +665.4 KB - Content
- Flash_G1.pdf
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.0 KB - Content
- GOTTHARD noise evaluation and exposure time dependence (002).pdf
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +304.6 KB - Content
- MP-E_65mm_F2.8_1-5x_Instruction_DE.pdf
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +284.0 KB - Content
- READ_ME_GOTTHARD_detector.pdf
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.4 KB - Content
- cfeld-gotthard02.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.1 KB - Content
- hasdslabgh.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.5 KB - Content
- image2023-9-15_11-16-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.rangeadm - Size
-
... ... @@ -1,0 +1,1 @@ 1 +258.7 KB - Content