... ... @@ -116,7 +116,7 @@
116 116  * /asap3/flash/gpfs/ //beamline used// / //year// /data/ //Beamtime application number// /raw/hdf/ (the //Beamtime application number// can be fund in the pdf schedule sent around by Rolf ...)
117 117  * as example: {{code language="none"}}/asap3/flash/gpfs/bl2/2017/data/11003163/raw/hdf/{{/code}}
118 118  
119 -More details and links can be found in the [[doc:FLASHUSER.User overview]].
119 +More details and links can be found in the [[doc:FLASHUSER.Data Acquisition and controls.DAQ and controls overview.WebHome]].
120 120  
121 121  \\
122 122  
... ... @@ -365,9 +365,9 @@
365 365  \\
366 366  
367 367  *
368 -** one has to go to the "Run Modes" tab and select the run mode {{code language="none"}}FLASH1_EXP{{/code}} by clicking on it !
369 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/runmode_set.jpg~|~|alt="runmode_set.jpg" width="400" height="400"~]~]>>attach:runmode_set.jpg]]
370 -** then one has to go back to the {{code language="none"}}Subsystems{{/code}} . now all subsystems are included.
368 +** one has to go to the "Run Modes" tab and select the run mode {{code language="none"}}FLASH1_EXP{{/code}} by clicking on it and choose the desired file size (stored settings)
369 +[[image:attach:image2019-10-24_15-29-36.png||height="400"]]
370 +** then one has to go back to the {{code language="none"}}Subsystems{{/code}} . initially all subsystems are included.
371 371  ** finally you have to select your White list and start a run ...
372 372  
373 373  \\
... ... @@ -384,9 +384,15 @@
384 384  
385 385  [[Some more details for experts ...>>doc:FLASH.Collection of Detailsof the DAQ from various times \.\.\. not for public use]]
386 386  
387 +=== Re-read the data base ===
388 +
389 +If there are new Properties included by Vladimir et al one has to reread the data base.
390 +
391 +This can be done easiest by going to the run modes and choose a different "stored setting" (changing e.g. from filesize 100 MB to 350 MB) and going back to subsystems. At this point the new database entries are read in. then one can do the same backwards to switch back to the initial file size. Doing this the configured list of subsystems is lost and one has to reload the whitelist and start a run to get the loaded whitelist in the configuration.
392 +
387 387  \\
388 388  
389 -=== Re-read the data base ===
395 +OR one can do the hard way:
390 390  
391 391  On flashlxuser1 or 2 start RCGUIFL1USER1 or appropriate to the DAQ you want to reconfigure. Select the tab "Run Modes". To then reload or re-init the run control database you need the expert menu entry:
392 392