Changes for page How to save data in the User DAQ
Last modified by sndueste on 2025-09-08 15:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. cpassow1 +XWiki.erlandm - Content
-
... ... @@ -20,11 +20,12 @@ 20 20 21 21 === DAQ control panel === 22 22 23 -To get to the User DAQ control one has to go to {{code language="none"}}Experiment control{{/code}} -> {{code language="none"}}User DAQ tab{{/code}} -> {{code language="none"}}FLxUSERy DAQ CTRL{{/code}} 24 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/jddd_DAQ-control-manual-how_to_get.png~|~|alt="jddd_DAQ-control-manual-how_to_get.png" width="500" height="360"~]~]>>attach:jddd_DAQ-control-manual-how_to_get.png]] 23 +To get to the User DAQ control one has to go to {{code language="none"}}Experiment control{{/code}} -> {{code language="none"}}User DAQ tab{{/code}} -> {{code language="none"}}FLxUSERy DAQ CTRL{{/code}} 24 + 25 +[[image:attach:jddd_DAQ-control-manual-how_to_get.png||height="400"]] 25 25 \\The following window opens. Here the User DAQ can be started and stopped as well as the incoming data can be visualized, information about data rates and saved properties is presented as well as the panel is automatically printed in to the logbook: 26 26 27 -[[ ~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/jddd_DAQ-control-manual2.png~|~|alt="jddd_DAQ-control-manual2.png" width="960" height="720"~]~]>>attach:jddd_DAQ-control-manual2.png]]28 +[[image:attach:jddd_DAQ-control-manual2.png||height="400"]] 28 28 \\\\ 29 29 30 30 \\ ... ... @@ -66,7 +66,7 @@ 66 66 67 67 ==== Offline DAQ monitor ==== 68 68 69 -This tool looks if a predefined selection of parameters is saved in the raw file. When a raw.-file reached its maximum size ( ~~ 1 GB) it is closed and a new file is opened. Once closed, the Offline DAQ monitor reads the file and checks if there are entris for the selected parameters. It shows the fraction of events containing data. For “fast” data (data written with 10 Hz and bunch ID synchronous like images, ADC traces) this should be close to 100%. For “slow” data (saved about every second e.g. pressures , temperatures...) this is about 10-20%. **However it is to note** that this program just check if there is **anything** saved. It does not check if it is the proper data. 70 +This tool looks if a predefined selection of parameters is saved in the raw file. When a raw.-file reached its maximum size ( ~~ 1 GB) it is closed and a new file is opened. Once closed, the Offline DAQ monitor reads the file and checks if there are entries for the selected parameters. It shows the fraction of events containing data. For “fast” data (data written with 10 Hz and bunch ID synchronous like images, ADC traces) this should be close to 100%. For “slow” data (saved about every second e.g. pressures , temperatures...) this is about 10-20%. **However it is to note** that this program just check if there is **anything** saved. It does not check if it is the proper data. 70 70 71 71 \\ 72 72 ... ... @@ -74,12 +74,13 @@ 74 74 75 75 To ultimately check if the correct data is saved one can use the DAQ data GUI to look at the saved raw. files. 76 76 77 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/DAQgui1.jpg~|~|alt="DAQgui1.jpg" width="500" height="350"~]~]>>attach:DAQgui1.jpg]][[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/DAQgui2.jpg~|~|alt="DAQgui2.jpg" width="500" height="350"~]~]>>attach:DAQgui2.jpg]][[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/daqgui3.png~|~|alt="daqgui3.png" width="500" height="350"~]~]>>attach:daqgui3.png]] 78 +[[image:attach:daqgui3.png||height="250"]][[image:attach:DAQgui2.jpg||height="250"]][[image:attach:DAQgui1.jpg||height="250"]] 79 + 78 78 \\ 79 79 80 -The DAQ Data GUI is a general tool to select and visuali se data that was saved in the DAQ . It has in addition simple analysis options like histogram, mean, min or max values as function of time etc. Also correlations between different parameters can be analyzed in the tool. More details can be found [[How to Use the FLASH DAQ Data GUI?~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/FLASHWiki/Wiki.jsp?page=FLASHDAQdataGUI||shape="rect"]] and [[ here (DAQdataGUI link collection) >>doc:FLASH.How to get the data out of the DAQ]]82 +The DAQ Data GUI is a general tool to select and visualize data that was saved in the DAQ . It has in addition simple analysis options like histogram, mean, min or max values as function of time etc. Also correlations between different parameters can be analyzed in the tool. More details can be found [[How to Use the FLASH DAQ Data GUI?~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/FLASHWiki/Wiki.jsp?page=FLASHDAQdataGUI||shape="rect"]] and [[ here (DAQdataGUI link collection) >>doc:FLASH.How to get the data out of the DAQ]] 81 81 82 -The tool (separate Java program) can be started [[DAQdataGUI~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://ttfinfo2.desy.de/common/applications/DAQdataGUI-experimental.jnlp||shape="rect"]] or in the DAQ control panel ( lower right) on your local (Desy) PC. In some cases the access via Windows does not work. An option which should always work is to log onto {{code language="none"}}flashlxuser1{{/code}} or {{code language="none"}}flashlxuser 2{{/code}} and start {{code language="none"}}DAQdataGUI{{/code}} from the command line.84 +The tool (separate Java program) can be started [[DAQdataGUI~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://ttfinfo2.desy.de/common/applications/DAQdataGUI-experimental.jnlp||shape="rect"]] or in the DAQ control panel ( lower right) on your local (Desy) PC. In some cases the access via Windows does not work. An option which should always work is to log onto {{code language="none"}}flashlxuser1,flashlxuser2{{/code}} or {{code language="none"}}flashlxuser3{{/code}} and start {{code language="none"}}DAQdataGUI{{/code}} from the command line. 83 83 84 84 85 85 \\To access the desired data one has to: ... ... @@ -97,16 +97,15 @@ 97 97 The (% class="twikiNewLink" %)DAQdataGui(%%) is a powerful tool to visualize the saved data and to do very preliminary analysis. however for more detailed analysis the data has to be read into analysis programs ( matlab, python, Origin ...) here are different options one can use (what option is the best and how to set it up has to be discussed before hand with the FLASH DAQ experts ...) 98 98 99 99 * The FLASH DAQ system records the data in binary " {{code language="none"}}.raw{{/code}} " files. 100 -** [[reading the data via Matlab >>doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).For experts\: many ways to get Data from the DAQ.How to Access the DAQ Using Matlab.WebHome]] works not for all data types equally well and needs precise knowledge of the desired Parameters (useful to have a quick look / preliminary analysis on few parameters).102 +** (% class="confluence-link" %)reading the .raw files [[directly via Python>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp?page=PythonDAQClientInterface||shape="rect"]], or [[via Matlab >>doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).For experts\: many ways to get Data from the DAQ.How to Access the DAQ Using Matlab.WebHome]](%%)(no longer recommended) works, yet not for all data types equally well, and needs precise knowledge of the desired Parameters (useful to have a quick look / preliminary analysis on few parameters). 101 101 ** Note that the raw data is only accessible from certain computers within the DESY network and thus not very handy for offline analysis later on ... 102 102 103 103 \\ 104 104 105 105 * To ease the data analysis we IN ADDITION provide //ON REQUEST// the data from the FLASH DAQ as HDF5 format 106 -** ONLINE HDF5s: To make efficient use of the HDF5 files for analysis during the beamtime and afterwards we provide a [[very useful tool (Beamtime Daq Access)>>doc:FLASHUSER.Near-Online data analysis]]. Using this tool (working for Python and Matlab) one can get the data of parameters per run or for specific bunch ID intervals etc. without having to care from which subset of HDF5 files the data is read ... 107 -** Summary HDF5 files include complete runs. They will be put after the beamtime on the gpfs storage and are available from computers within DESY (for registered Beamtime participants) and also access 108 -** Intro to the [[HDF5 structure used at FLASH>>doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).The FLASH HDF5 structure.WebHome]]. This contains also a list of the most used Parameters saved at FLASH for analysis - including the HDF5 names, DOOCS and DAQ names ... 109 -** [[Short examples>>doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).The FLASH HDF5 structure.WebHome]] and [[user provided examples>>doc:FLASH.Collection of user codes]] on how to read HDF5 in Matlab 108 +** ONLINE HDF5s: Intro to the [[HDF5 structure used at FLASH>>doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).The FLASH HDF5 structure.WebHome]]. This contains also a list of the most used Parameters saved at FLASH for analysis - including the HDF5 names, DOOCS and DAQ names ... 109 +** [[Examples>>url:https://gitlab.desy.de/christopher.passow/flash-daq-hdf||shape="rect"]] and an [[API>>url:https://gitlab.desy.de/christopher.passow/fdh-builder||shape="rect"]] to make use of the online HDF5s 110 +** [[Short examples>>doc:FLASHUSER.Data Acquisition and controls.Data Access at FLASH (DAQ, gpfs,\.\.\.).Offline data analysis (DAQ).The FLASH HDF5 structure.WebHome]] and [[user provided examples>>doc:FLASH.OUTDATED - Collection of user codes]] on how to read HDF5 in Matlab (no longer recommended). 110 110 111 111 The HDF5 files (online and summary) are saved in the [["gpfs" system ~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://confluence.desy.de/display/ASAP3/Architecture||shape="rect"]]. it can be accessed from [[Windows and Linux computers at DESY~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://confluence.desy.de/display/ASAP3/Mounting+the+storage+system+at+the+beamline||shape="rect"]] by the persons ( logins) which are registered for the beamtime in DOOR ( functional accounts 112 112 ... ... @@ -131,12 +131,12 @@ 131 131 132 132 === Configuring the DAQ === 133 133 135 +[[image:attach:RCGUI_2.jpg||height="400"]] 136 +\\ 134 134 135 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/RCGUI_2.jpg~|~|alt="RCGUI_2.jpg" width="400" height="500"~]~]>>attach:RCGUI_2.jpg]] 136 - 137 -Using the jddd DAQ control panel one can start and stop runs but in order to configure the DAQ which data to save one has to use a a separate *DAQ run control * java application. Since it needs write access to DOOCS internal file systems, which can not be made available elsewhere one has to start the system on our DOOCS control computers [[flashlxuser1.desy.de>>url:http://flashlxuser1.desy.de||shape="rect"]]{{code language="none"}}{{/code}} or [[flashlxuser2.desy.de>>url:http://flashlxuser2.desy.de||shape="rect"]]{{code language="none"}}{{/code}}. 138 +Using the jddd DAQ control panel one can start and stop runs but in order to configure the DAQ which data to save one has to use a a separate *DAQ run control * java application. Since it needs write access to DOOCS internal file systems, which can not be made available elsewhere one has to start the system on our DOOCS control computers {{code language="none"}}flashlxuser1.desy.de, flashlxuser2.desy.de {{/code}} or {{code language="none"}}flashlxuser3.desy.de{{/code}}. 138 138 Log in with the beamline account (bl1user, bl2user, ..., fl24user...) either via X-Win32 from windows or via ssh from Linux machines. 139 -Once logged in to {{code language="none"}}flashlxuser1 {{/code}} or {{code language="none"}}flashlxuser2{{/code}} the DAQ run control can be started. Depending on the DAQ you want to use the commands are:140 +Once logged in to {{code language="none"}}flashlxuser1,2,3{{/code}} the DAQ run control can be started. Depending on the DAQ you want to use the commands are: 140 140 141 141 \\ 142 142 ... ... @@ -177,13 +177,11 @@ 177 177 178 178 Which DAQ to use is decided by the FLASH DAQ team according to the beamtime schedule. 179 179 180 - \\181 +[[image:attach:RCGUI_properties.jpg||height="400"]] 181 181 182 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/RCGUI_properties.jpg~|~|alt="RCGUI_properties.jpg" width="503" height="311"~]~]>>attach:RCGUI_properties.jpg]] 183 - 184 184 \\ 185 185 186 -Using the {{code language="none"}}Add{{/code}} and {{code language="none"}}Rem(ove){{/code}} buttons one can move the desired "subsystems" in the included side - meaning that they are saved. The "subsystems" contain typically several DOOCS parameters. E.g. {{code language="none"}}EXPERIMENT_MHZ_ADC_BL1{{/code}} contains all relevant DOOCS properties of the 4 MHZ ADC channels available at BL1. To get a detail led information about the saved parameters one can have a look to the "Show Properties in Subsystems" button . In addition, a list of all possible subsystems and their description can be found [[here>>doc:FLASHUSER.Configuring the user DAQs]].185 +Using the {{code language="none"}}Add{{/code}} and {{code language="none"}}Rem(ove){{/code}} buttons one can move the desired "subsystems" in the included side - meaning that they are saved. The "subsystems" contain typically several DOOCS parameters. E.g. {{code language="none"}}EXPERIMENT_MHZ_ADC_BL1{{/code}} contains all relevant DOOCS properties of the 4 MHZ ADC channels available at BL1. To get a detailed information about the saved parameters one can have a look to the "Show Properties in Subsystems" button . In addition, a list of all possible subsystems and their description can be found [[here>>doc:FLASHUSER.Configuring the user DAQs]]. 187 187 188 188 \\ 189 189 ... ... @@ -212,9 +212,8 @@ 212 212 213 213 === Load/Save the configuration === 214 214 214 +[[image:attach:whitelist.jpg||height="400"]] 215 215 216 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/whitelist.jpg~|~|alt="whitelist.jpg" width="532" height="370"~]~]>>attach:whitelist.jpg]] 217 - 218 218 Once a list of subsystems is defined and tested this parameter combination should then be saved in a so-called //white list//. By loading this white list one can then easily configure the DAQ after changes / restarts ... to the initially defined settings to save the correct data. 219 219 The whitelist can be saved/loaded with the Run Control GUI by: {{code language="none"}}File -> Group White List -> Save/Load{{/code}}. Note, while the top left rectangle's background of time and date is yellow, don't try any further controls of the GUI, you might confuse the program. It is busy reading the configuration from the run control database. The background changes back to grey when it has finished. 220 220 \\The filename convention for the White Lists are arranged in the way: ... ... @@ -236,7 +236,7 @@ 236 236 * 350 MB: Often a good compromise ... 237 237 * 100 MB: It is not preferred to have many "small" files for storing the data. For very small data rates this is an option to not wait too long till the next file is created. 238 238 239 -To choose the desired filesize one has to choose a run mode configuration in the RunControlGUI 237 +To choose the desired file size one has to choose a run mode configuration in the RunControlGUI 240 240 241 241 [[~[~[image:attach:image2020-1-17_13-39-38.png~|~|height="400"~]~]>>attach:image2020-1-17_13-39-38.png]] 242 242 ... ... @@ -261,16 +261,13 @@ 261 261 The jddd DAQ Control should be set up that it prints by default the relevant run information in the logbook associated to your beamline [[Logbooks>>doc:FLASH.Electronic Logbooks]] 262 262 263 263 Define logbook / and whitelist for display in the jddd DAQ control (jddd otherwise does not "know" which White list was used ... this has to be put in by hand ...up to now) 264 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/setting_parameters.jpg~|~|alt="setting_parameters.jpg" width="500" height="300"~]~]>>attach:setting_parameters.jpg]] 265 265 266 - \\263 +[[image:attach:setting_parameters.jpg||height="400"]] 267 267 268 268 \\ 269 269 270 270 \\ 271 271 272 -\\ 273 - 274 274 == In case something goes wrong: Troubleshooting == 275 275 276 276 \\ ... ... @@ -277,7 +277,7 @@ 277 277 278 278 === No //START// or //STOP// buttons are visible in the DAQ control panel === 279 279 280 -~* The jddd GUI only shows the Start and stop bu nnon if the DAQ is in the "Idle" state. sometimes the DAQ "just" gets stuck in the stopping phase. Then stopping again or starting form the not "Idle" state can help. For this goto the "Advanced" tab of the jddd DAQ control . there the START and STOP buttons are always available ... independent of the state of the DAQ. If this does not help you may have to restart the DAQ ...275 +~* The jddd GUI only shows the Start and stop button if the DAQ is in the "Idle" state. sometimes the DAQ "just" gets stuck in the stopping phase. Then stopping again or starting form the not "Idle" state can help. For this goto the "Advanced" tab of the jddd DAQ control . there the START and STOP buttons are always available ... independent of the state of the DAQ. If this does not help you may have to restart the DAQ ... 281 281 282 282 \\ 283 283 ... ... @@ -293,9 +293,11 @@ 293 293 294 294 === Data seems not properly saved === 295 295 291 +[[image:attach:RC_logfile.jpg||height="250"]] 296 296 297 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/RC_logfile.jpg~|~|alt="RC_logfile.jpg" width="518" height="300"~]~]>>attach:RC_logfile.jpg]]When checking the saved run with the (% class="twikiNewLink" %)DAQdataGUI(%%) it may happen that the property shows up in the data tree but no events are saved. Then (most likely) something is wrong with the sending of the data. 298 298 294 + When checking the saved run with the (% class="twikiNewLink" %)DAQdataGUI(%%) it may happen that the property shows up in the data tree but no events are saved. Then (most likely) something is wrong with the sending of the data. 295 + 299 299 * A very helpful tool is the {{code language="none"}}RC logfile{{/code}}. in the RCGUI on the lower right side there is a button to start an editor with the log file. besides lots of standard entries there is usually also a hint on where to find the problem ... 300 300 * check if the device is working properly. Is it connected? Can you see data in jddd / DOOCS ? . If not you have to fix the DOOCS part ... DAQ can only save what is properly implemented in DOOCS. 301 301 * If camera images are not properly saved ( e.g. only "0"s in the image matrix or the DAQ sender can not be switched to "on") a **restart of the camera server** usually helps. ... ... @@ -317,7 +317,7 @@ 317 317 \\ 318 318 319 319 * Generally there 3 ways to "restart" the DAQ 320 -** 1. The least interfer ring way is the "all to INITIALIZE" that tries to reset the DAQ processes ... helps for simple "hickups"317 +** 1. The least interfering way is the "all to INITIALIZE" that tries to reset the DAQ processes ... helps for simple "hickups" 321 321 ** 2. The "re-start DAQ" really reboots the whole DAQ process. The settings still should be as before ... this is the "Usual" restart 322 322 ** 3. In very hard and severe cases there is the ultimate restart button: "re-start DAQ (no RCSHM)" 323 323 ... ... @@ -327,26 +327,25 @@ 327 327 \\ 328 328 329 329 * if the DAQ gets stuck in the starting or stopping procedure one can try to initialize the DAQ or in the worst case restart it. 330 -** **to be able to restart the DAQ one has to run jddd on the {{code language="none"}}flashlxuser1{{/code}} or {{code language="none"}}flashlxuser 2{{/code}} (up to now ( 2020) the restat on our consoles (cons0...12) is NOTpossibleyet[[image:url:http://hasfweb.desy.de/pub/TWiki/SmiliesPlugin/frown.gif||alt="frown"]]) : log in at one of these machines with your beamline account (e.g. bl1user or fl24user). Start jddd with the {{code language="none"}}flash{{/code}} command. Click on "Photons" -> Experimental Hall "Photons main panel"**327 +** **to be able to restart the DAQ one has to run jddd on the {{code language="none"}}flashlxuser1,flashlxuser2{{/code}} or {{code language="none"}}flashlxuser3{{/code}} (up to now ( 2021) the restat on our consoles (cons0...12) is NOT reliably possible ) : log in at one of these machines with your beamline account (e.g. bl1user or fl24user). Start jddd with the {{code language="none"}}flash{{/code}} command. Click on "Photons" -> Experimental Hall "Photons main panel"** 331 331 ** The DAQ "expert" panel can be reached from the User DAQ control panel. 332 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/DAQ_expert.jpg~|~|alt="DAQ_expert.jpg" width="400" height="350"~]~]>>attach:DAQ_expert.jpg]] 333 333 330 + [[image:attach:DAQ_expert.jpg||height="400"]] 334 334 \\ 335 335 336 -\\ 337 - 338 338 * 339 339 ** Then you see the following "DAQ expert panel": 340 340 ** first one may try the "all to INITIALIZE" button. it starts a script window and asks for the passwd (the beamline accounts (blxuser) should have the according rights. vuvfuser has it for sure. The script sets all subcomponents to initialize. It is helpful if one subcomponent got stuck. 341 341 337 + [[image:attach:UserDAQ_status.jpg||height="400"]] 338 +\\ 342 342 343 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/UserDAQ_status.jpg~|~|alt="UserDAQ_status.jpg" width="500" height="400"~]~]>>attach:UserDAQ_status.jpg]] 344 - 345 345 \\ 346 346 347 347 * If this does not help you have to "re-start DAQ". This completely restarts all processes and takes a while. A script window appears and shows what steps are actually done. At the end is sais: "Cleanup finished". 348 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/DAQ_restart_msg.jpg~|~|alt="DAQ_restart_msg.jpg" width="400" height="350"~]~]>>attach:DAQ_restart_msg.jpg]] 349 349 344 + [[image:attach:DAQ_restart_msg.jpg||height="400"]] 345 + 350 350 \\ 351 351 352 352 * For the "re-start DAQ" the DAQ should come up in the same state as before. Meaning that the subsystems (ADCs, cameras ..) are still loaded and displayed. If this is not the case you can try to load your white list and start a new run. If the data is saved correctly you are done. ... ... @@ -356,10 +356,12 @@ 356 356 * **IF the DAQ still does not work properly** the final option is the: "re-start DAQ (no RCSHM)". This button does the same as the "re-start DAQ" but the Run Controller shared memory is **not** re-stored. It means that after the DAQ is back no run configuration is selected. 357 357 ** in the jddd control the list of subsystems sais "empty" 358 358 ** in the RCGUI in the lower part it sais "RUN mode is not set" 359 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/DAQjddd/restart_RCM_no_runmode.jpg~|~|alt="restart_RCM_no_runmode.jpg" width="400" height="400"~]~]>>attach:restart_RCM_no_runmode.jpg]] 360 360 356 + [[image:attach:restart_RCM_no_runmode.jpg||height="400"]] 361 361 \\ 362 362 359 +\\ 360 + 363 363 * 364 364 ** one has to go to the "Run Modes" tab and select the run mode {{code language="none"}}FLASH1_EXP{{/code}} by clicking on it and choose the desired file size (stored settings) 365 365 ** then one has to go back to the {{code language="none"}}Subsystems{{/code}} . initially all subsystems are included. ... ... @@ -389,7 +389,7 @@ 389 389 390 390 OR one can do the hard way: 391 391 392 -On flashlxuser1 or 2start RCGUIFL1USER1 or appropriate to the DAQ you want to reconfigure. Select the tab "Run Modes". To then reload or re-init the run control database you need the expert menu entry:390 +On flashlxuser1,2 or 3 start RCGUIFL1USER1 or appropriate to the DAQ you want to reconfigure. Select the tab "Run Modes". To then reload or re-init the run control database you need the expert menu entry: 393 393 394 394 {{code language="none"}}Options -> "Show Expert Menu"{{/code}} 395 395 ... ... @@ -415,8 +415,10 @@ 415 415 416 416 The red flags next to the different stream indicators tell something about data base errors 417 417 418 - [[image:url:https://mail.desy.de/service/home/~~/?auth=co&loc=de&id=154203&part=2.2||width="788" height="140"]]416 +\\ 419 419 418 +[[image:attach:2021-02-10 15_23_20-How to save data in the User DAQ - FS-FLASH USER - DESY Confluence.png||width="600"]] 419 + 420 420 upper flag: There was a problem to read run catalogue 421 421 422 422 lower flag: There was a problem to read dccp catalogue.