Changes for page The FLASH HDF5 structure
Last modified by sndueste on 2025/09/10 11:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -120,10 +120,13 @@ 120 120 === FLASH1 === 121 121 122 122 123 -In the Shutdown 2024 / 2025 the complete photon diagnostic and experiment control was renewed and thus the Doocs names and also some HDF5 names had to be changed. The 123 +In the Shutdown 2024 / 2025 the complete photon diagnostic and experiment control was renewed and thus the Doocs names and also some HDF5 names had to be changed. The new naming will be documented here as soon as the systems are online again. 124 124 125 - ====Beamlineinfo(FLASH1)====125 +The previously used naming scheme (2024 and before) can be found here: 126 126 127 +{{expand expanded="false" title="FLASH1 Naming scheme used until 2024"}} 128 +==== (% id="cke_bm_8853497S" style="display:none" %) (%%)Beamline info (FLASH1) ==== 129 + 127 127 {{code language="none"}}/FL1/Beamlines/Attenuator/pressure{{/code}} 128 128 //always saved (PBD)// 129 129 DOOCS prop : {{code language="none"}}FLASH.FEL/GAS_DOSING/FL1.ATTENUATOR/PRESSURE{{/code}} ... ... @@ -244,8 +244,8 @@ 244 244 245 245 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Average energy/energy tunnel{{/code}} 246 246 //always saved (PBD)// 247 -(% style="color:#000000" %)DOOCS prop : 248 -(% style="color:#000000" %)DAQ channel: 250 +(% style="color:#000000" %)DOOCS prop : {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} (%%) 251 +(% style="color:#000000" %)DAQ channel: {{code language="none"}}FLASH.FEL/XGM.PHOTONFLUX/FL1.TUNNEL/PHOTONFLUX.UJ{{/code}} 249 249 250 250 desc : calibrated average SASE Energy/pulse measured in the TUNNEL upstream the gas attenuator 251 251 units : microJ ... ... @@ -254,8 +254,8 @@ 254 254 {{code language="none"}}/FL1/Photon Diagnostic/GMD/Pulse resolved energy/energy tunnel{{/code}} 255 255 //always saved (PBD)// 256 256 257 -(% style="color:#000000" %)DOOCS prop : 258 -{{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}} 260 +(% style="color:#000000" %)DOOCS prop : (%%) 261 +(% style="color:#000000" %){{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}}DAQ channel: {{code language="none"}}FLASH.FEL/XGM.INTENSITY/FL1.TUNNEL/INTENSITY.TD{{/code}} 259 259 260 260 desc : Energy per pulse measured in the Tunnel. In addition measurement errors and beam position are included for EACH pulse in the pulse train !! (see below) 261 261 units : a.u. (more or less µJ but need to be calibrated with the "Average energy" for good precision)** [[see here for help>>doc:FS-FLASH USER tmp.jddd-linked help pages.Calibrating the pulse resolved (electron) data from GMD.WebHome]]** ... ... @@ -275,8 +275,7 @@ 275 275 The pulse energy and the error are plotted for the first bunch of the pulse trains saved in this 276 276 file 277 277 278 - 279 -[[image:attach:image2021-2-9_10-51-6.png||height="250"]] 281 + [[image:image2021-2-9_10-51-6.png]] 280 280 281 281 282 282 {{/info}} ... ... @@ -468,8 +468,8 @@ 468 468 469 469 //always saved (PBD)// 470 470 (% style="color:#172b4d" %)**FL1.SFELC**(%%) 471 -(% style="color:#000000" %)channel: FLASH.SDIAG/BAM/(% style="color:#172b4d" %)FL1.SFELC(% style="color:#000000" %)/ARRIVAL_TIME.ABSOLUTE.SA1.COMP 472 -{{code language="none"}} DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIME.ABSOLUTE.SA1.COMPDAQ {{/code}}(% style="letter-spacing:0.0px" %)desc: Electron bunch arrival time measured with the BAM before the undulator (pulse resolved data). This one was newly installed in 2020.. The property contains only the arrival time of the bunches sent to FL1 (e.g. if there are 30 bunches in FL1 the first 30 values are the arrival time the remaining numbers still may have arbitrary numbers looking like a signal which they are not). These are the same values as the "raw" data below - just "cleaned". The values show a very good correlation to the arrival time of the XUV pulses in the experiment (see help). 473 +(% style="color:#000000" %)channel: FLASH.SDIAG/BAM/(% style="color:#172b4d" %)FL1.SFELC(% style="color:#000000" %)/ARRIVAL_TIME.ABSOLUTE.SA1.COMP(%%) 474 +(% style="color:#000000" %){{code language="none"}} DOOCS prop : FLASH.SDIAG/BAM//ARRIVAL_TIME.ABSOLUTE.SA1.COMPDAQ {{/code}}(% style="letter-spacing:0.0px" %)desc: Electron bunch arrival time measured with the BAM before the undulator (pulse resolved data). This one was newly installed in 2020.. The property contains only the arrival time of the bunches sent to FL1 (e.g. if there are 30 bunches in FL1 the first 30 values are the arrival time the remaining numbers still may have arbitrary numbers looking like a signal which they are not). These are the same values as the "raw" data below - just "cleaned". The values show a very good correlation to the arrival time of the XUV pulses in the experiment (see help). 473 473 units: fs (bigger numbers (typically) indicate later arrival times of the electrons). 474 474 475 475 ... ... @@ -545,8 +545,11 @@ 545 545 units: nm 546 546 547 547 [[Contents>>doc:||anchor="Contents"]] 550 +{{/expand}} 548 548 552 +==== ==== 549 549 554 + 550 550 ==== Timing information, rep rate etc. (FLASH1) ==== 551 551 552 552 ===== bunch repetition rate =====