Last modified by sndueste on 2023/06/15 14:33

From version 1.1
edited by sndueste
on 2020/09/25 17:09
Change comment: There is no comment for this version
To version 3.1
edited by sndueste
on 2021/02/10 12:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,8 +2,10 @@
2 2  
3 3  There are 2 mirror protection servers ( one for the 2 mirrors in the tunnel and one for the experimental hall)
4 4  
5 -[[image:attach:Clipboard12.jpg||thumbnail="true" height="250"]]
5 +\\
6 6  
7 +[[image:attach:image2020-9-25_17-12-45.png||height="250"]]
8 +
7 7  \\
8 8  
9 9  The server checks that for the set wavelength the coating of the mirrors is appropriate. IF NOT the tunnel protection server will close PS1 and the hall protection server will close PS2. The closing is combined with a warning indicating the problem.
... ... @@ -23,3 +23,22 @@
23 23  If the protection server, wavelength server or mirror moving server is unavailable or has some errors the message  [[image:attach:image2020-9-25_17-9-19.png||thumbnail="true" height="50"]] will be displayed.
24 24  
25 25  \\
28 +
29 +\\
30 +
31 +== Expert stuff: ==
32 +
33 +FLASH.UTIL/MIRROR.PROTECTION/FL2.HALL/ACTION indicates actions the server will do, 0=ok, >0 will be close
34 +
35 +0 = ok
36 +1 = closing absorbler
37 +2 = absorber already closed
38 +3 = absorber control disabled
39 +
40 +\\
41 +
42 +\\
43 +
44 +If parameters like TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH.USED  are not readable  → generate warning
45 +