Changes for page Gotthard related stuff
Last modified by sndueste on 2023/09/25 09:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. sndueste1 +XWiki.palutke - Content
-
... ... @@ -5,7 +5,6 @@ 5 5 * [[Data sheet of a macro objective>>attach:MP-E_65mm_F2.8_1-5x_Instruction_DE.pdf]] 6 6 * [[FLASH-GH-Meeting_10.10.2014.pdf by Steffen>>attach:FLASH-GH-Meeting_10.10.2014.pdf]] 7 7 * [[attach:READ_ME_GOTTHARD_detector.pdf]]: READ_ME_GOTTHARD_detector.pdf (Server information is outdated, see below) 8 -* some investigation related to read out noise for different exposure times [[attach:GOTTHARD noise evaluation and exposure time dependence (002).pdf]] 9 9 10 10 \\ 11 11 ... ... @@ -12,8 +12,8 @@ 12 12 Ethernet connections: 13 13 14 14 (% style="list-style-type: square;" %) 15 -* gbit port 16 -* base-T 14 +* gbit port <~-~--> Server PC (hasfl2det01 at FLASH2, no server currently at FLASH1) 15 +* base-T <~-~--> Office net 17 17 18 18 == How to use the Detector and save in DAQ == 19 19 ... ... @@ -34,37 +34,10 @@ 34 34 35 35 \\ 36 36 37 -== Operation hints (June 2023): == 38 - 39 -(% style="list-style-type: square;" %) 40 -* **Where is the GOTTHARD GUI:** FLASH2 - Panel: Infrastructure tab → Miscellaneous tab → FLASH2 GOTTHARD ctrl button 41 -* **Never change a running system:** Do not change parameters while the Detector is running/taking data, The detector will crash. 42 -* Furthermore the module will crash if recieving to much light (e.g. illuminating with flash light during data dating. 43 -* **Checking/switching server:** The server is reachable from the GOTTHARD GUI (lower left corner find the status of the server PC "hasfl2det01") click it to open server/watchdog control. The server is otherwise found under FLASH.SYSTEM → HASFL2DET01.WATCH. Open control of SVR.GOTTHARD (for start/stop/reboot) 44 - 45 -(% style="list-style-type: square;" %) 46 -* **Robooting the GOTTHARD** (if it has crashed): 47 -(% style="list-style-type: square;" %) 48 -** soft reboot: 1. open console on linux DESY PC, 2. type "telnet (Hostname/IP)" e.g. "telnet cfeld-gotthard02" , 3. you are logged on the GOTTHARD module as /root, type "reboot", 4. wait until server/GUI has reconnected to the module 49 -** hard reset: power down the GOTTHARD, wait some seconds, Repower the module, wait for reconnection to server/GUI 50 -* **In case of a crashes** (no data taking, no reaction on input: Reboot the detector) or if GUI input returns error: Check connection (Power/Data), check GOTTHARD server 51 -* **Permantent operation:** Activate check box for continous run to trigger automated restart of the module after reaching the set number of short or after sefl-stopping due to hickups. The restart needs about 1-2 seconds. During this time no data is taken. 52 -* **Background**: Check "Take" stores the actual detector image~: Uncheck this again. Than this stored image is online subtracted from all images in the GUI when checking "subtract". The DAQ only stores raw data (NOT the background subtracted images) 53 - 54 -Using burst mode (standard operation as of June 2023) 55 - 56 -(% style="list-style-type: square;" %) 57 -* Do not change the delay in the GOTTHARD GUI. The Alignment to the FEL pulses are done by adjusting the FLASH trigger: FL2EXP1/RTM.TRG6, it can be opened from the GOTTHARD GUI or from FLASH2 → Beamlines → FL26 → Exp. control → Patch Panel26-2 → MTCA Trigger 2 58 -* Exposure range is 2**00ns < Exposure < ~~1/3 * Frame periode** 59 -* The periode is:** 9968ns for 100kHz, 4984 for 200kHz, 1993 for 500kHz** 60 -* The number of** frames must be lower than 125, for stable operation 120** 61 -* Number of Shots: Number of trigger events before self stopping, select large number for permanent operation 62 - 63 63 == Modules and their exchange == 64 64 65 65 Two (Three) modules available (physically at FLASH): 66 66 67 -(% class="wrapped relative-table" style="width: 64.2451%;" %) 68 68 |=((( 69 69 hostname 70 70 )))|=((( ... ... @@ -71,8 +71,6 @@ 71 71 Status 72 72 )))|=((( 73 73 Sensor 74 -)))|=(% colspan="1" %)((( 75 -Sensor image 76 76 )))|=((( 77 77 config file 78 78 ))) ... ... @@ -79,33 +79,18 @@ 79 79 |((( 80 80 cfeld-gotthard02 81 81 )))|((( 82 - **standard**/online/working52 +standard/online/working 83 83 )))|((( 84 -(% class="content-wrapper" %) 85 -((( 86 86 two small areas of damaged pixels 87 -))) 88 -)))|(% colspan="1" %)((( 89 -(% class="content-wrapper" %) 90 -((( 91 -[[image:attach:cfeld-gotthard02.jpg||height="250"]] 92 -))) 93 93 )))|((( 94 94 bchip_mpc1922Receiver.config_cfeld-gotthard02 95 95 ))) 96 96 |((( 97 97 hasdslabgh 98 - 99 -"gotthard dgt01" 100 100 )))|((( 101 101 working 102 102 )))|((( 103 103 first 1/3 is blind, strong base line offset in the center and a further blind bunch and the end 104 -)))|(% colspan="1" %)((( 105 -(% class="content-wrapper" %) 106 -((( 107 -[[image:attach:hasdslabgh.jpg||height="250"]] 108 -))) 109 109 )))|((( 110 110 bchip_mpc1922Receiver.config 111 111 ))) ... ... @@ -112,18 +112,19 @@ 112 112 |((( 113 113 cfeld-gotthard01 114 114 )))|((( 115 -was working (2018) , backilluminated! the sensor front is Al-shielded for x-rays70 +was working (2018) 116 116 )))|((( 117 117 ? 118 -)))|(% colspan="1" %)((( 119 -\\ 120 120 )))|((( 121 121 bchip_mpc1922Receiver_petra.config 122 122 ))) 123 123 124 -\\ 77 +(% style="list-style-type: square;" %) 78 +* cfeld-gotthard02: standard/online/working 79 +* hasdslabgh: Flash1 module (lots of damaged pixels, working) 80 +* cfeld-gotthard01: back iluminated, spare part from PETRA (in principle working) 125 125 126 -To change a module the respective config file has to be selected. However changing it will crash the server, thus, it is not possible to change on the fly. Connact Sören if there is the need to exchange a module. However, the differences in the configs are only the hostname. ( **To be tested: On the fly might work, if one edits the config-file itself after switching of the server instead of selecting another config file in the GUI.But how to transport this information to the GUI? → Display the first line of the config file!**) The config files are located at the **hasfl2det01: /export/doocs/server/gotthard_server/cfgs/**82 +To change a module the respective config file has to be selected. However changing it will crash the server, thus, it is not possible to change on the fly. Connact Sören if there is the need to exchange a module. However, the differences in the configs are only the hostname. (To be tested: On the fly might work, if one edits the config-file itself after switching of the server instead of selecting another config file in the GUI.) The config files are located at the **hasfl2det01: /export/doocs/server/gotthard_server/cfgs/** 127 127 128 128 \\ 129 129 ... ... @@ -130,101 +130,3 @@ 130 130 == GOTTHARD Server == 131 131 132 132 The server for GOTTHARD (FLASH2) runs on **hasfl2det01**. Its watchdog and control (svr.GOTTHARD) can be found under** FLASH.SYSTEMS - HASFL2DET01.** 133 - 134 -\\ 135 - 136 -== Main Parameters and limits == 137 - 138 -(% class="wrapped" %) 139 -|=((( 140 -Parameter 141 -)))|=((( 142 -Design 143 -)))|=(% colspan="1" %)((( 144 -Real /tested 145 -))) 146 -|((( 147 -Max Frames 148 -)))|((( 149 -125 150 -)))|(% colspan="1" %)((( 151 -120 152 -))) 153 -|((( 154 -Max. exposition time 155 -)))|((( 156 -~~2/3 of period time 157 -)))|(% colspan="1" %)((( 158 -\\ 159 -))) 160 -|((( 161 -Min. period time 162 -)))|((( 163 -ca. 930 ns 164 -)))|(% colspan="1" %)((( 165 -\\ 166 -))) 167 -|((( 168 -Max repetition frequ. 169 -)))|((( 170 -1 MHz 171 -)))|(% colspan="1" %)((( 172 -833 kHz (software limited) 173 -))) 174 - 175 -\\ 176 - 177 -== Soft reset a GOTTHARD Module == 178 - 179 -(% style="list-style-type: square;" %) 180 -* Open console on Linux PC (connected to DESY net) 181 -* write "telnet cfeld-gotthard02" (or the respective Host name or IP of the module) 182 -(% style="list-style-type: square;" %) 183 -** you should be connected to the GOTTHARD onboard system → </root: 184 -* type: "reboot" 185 -(% style="list-style-type: square;" %) 186 -** the module reboots (wait ~~1-2 min), the telnat connection will be cut due to reboot. 187 - 188 -\\ 189 - 190 -== Triggering the Gotthard with a burst trigger == 191 - 192 -it is also possible to trigger the Gotthard not only with 10 Hz but with a burst trigger 193 - 194 -here are some Info from PIS (June 2023) 195 - 196 - 197 - 198 -{{view-file att--filename="Flash_G1.pdf" height="250"/}} 199 - 200 -I think one does not need to set it in GUI when running in continuous mode. In G1, whether the detector is running in burst or continuous mode depends on the setting of the "number of frames" in trigger mode. If the number of frames sets to 1, it will be in continuous mode (1 trigger -> 1 frame). 201 - 202 -Since G1 accepts triggers from the lemo connector, one can also use the bunch train trigger. The spacing of the trigger train needs to be larger than 3.2 ms, which is the readout time of G1. 203 - 204 -Regarding the detector setting (assuming it is 200 kHz pulse rate, 100 pulses per train): 205 - 206 -* timing mode: trigger 207 -* number of frames: 1 208 -* number of triggers: M x N (M is the number of trains and N is the pulses per train, one can also take a bit more frames per train to track the pedestal/dark) 209 -* period: < 5 us (1/200 kHz = 5 us, the period needs to be slightly smaller than 5 us since the detection of the trigger only starts after the period is reached) 210 -* exposure time: > 93 ns and smaller than period 211 - 212 -Alignment: One of the four lemo connectors on G1 outputs its exposure window. Using an oscilloscope, one can use a photodiode under the beam and align the pulses from the diode and the exposure window of G1 by fine tuning the exposure time of G1 and/or the setting of "delay after trigger" from the detector, or "delay time" of the wave-generator (if a wave-generator is used to generate the triggers for every pulse). After this, one can do a fine scan of trigger delay to find an optimal setting with highest signal after putting G1 under the beam. 213 - 214 -\\ 215 - 216 -by: 217 - 218 -Dr. Jiaguo Zhang 219 - 220 -Paul Scherrer Institut 221 - 222 -Forschungsstrasse 111 223 - 224 -5232 Villigen PSI 225 - 226 -Switzerland 227 - 228 -\\ 229 - 230 -\\