Changes for page Gotthard related stuff
Last modified by sndueste on 2023/09/25 09:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,8 +11,8 @@ 11 11 Ethernet connections: 12 12 13 13 (% style="list-style-type: square;" %) 14 -* gbit port <~-~--> Server PC (hasfl2det01 at FLASH2, no server currently at FLASH1) 15 -* base-T <~-~--> Office net 14 +* gbit port <~-~--> Server PC (hasfl2det01 at FLASH2, no server currently at FLASH1) 15 +* base-T <~-~--> Office net 16 16 17 17 == How to use the Detector and save in DAQ == 18 18 ... ... @@ -33,6 +33,28 @@ 33 33 34 34 \\ 35 35 36 +== Operation hints (June 2023): == 37 + 38 +(% style="list-style-type: square;" %) 39 +* **Where is the GOTTHARD GUI:** FLASH2 - Panel: Infrastructure tab → Miscellaneous tab → FLASH2 GOTTHARD ctrl button 40 +* **Never change a running system:** Do not change parameters while the Detector is running/taking data, The detector will crash. 41 +* Furthermore the module will crash if recieving to much light (e.g. illuminating with flash light during data dating. 42 +* **Checking/switching server:** The server is reachable from the GOTTHARD GUI (lower left corner find the status of the server PC "hasfl2det01") click it to open server/watchdog control. The server is otherwise found under FLASH.SYSTEM → HASFL2DET01.WATCH. Open control of SVR.GOTTHARD (for start/stop/reboot) 43 + 44 +(% style="list-style-type: square;" %) 45 +* **Robooting the GOTTHARD** (if it has crashed): 46 +(% style="list-style-type: square;" %) 47 +** soft reboot: 1. open console on linux DESY PC, 2. type "telnet (Hostname/IP)" e.g. "telnet cfeld-gotthard02" , 3. you are logged on the GOTTHARD module as /root, type "reboot", 4. wait until server/GUI has reconnected to the module 48 +** hard reset: power down the GOTTHARD, wait some seconds, Repower the module, wait for reconnection to server/GUI 49 +* **In case of a crashes** (no data taking, no reaction on input: Reboot the detector) or if GUI input returns error: Check connection (Power/Data), check GOTTHARD server 50 + 51 +Using burst mode (standard operation as of June 2023) 52 + 53 +(% style="list-style-type: square;" %) 54 +* Do not change the delay in the GOTTHARD GUI. The Alignment to the FEL pulses are done by adjusting the FLASH trigger: FL2EXP1/RTM.TRG6, it can be opened from the GOTTHARD GUI or from FLASH2 → Beamlines → FL26 → Exp. control → Patch Panel26-2 → MTCA Trigger 2 55 +* Exposure range is 100ns < Exposure < ~~1/3 * Frame periode 56 +* The periode is: 9968ns for 100kHz, 57 + 36 36 == Modules and their exchange == 37 37 38 38 Two (Three) modules available (physically at FLASH): ... ... @@ -101,3 +101,101 @@ 101 101 == GOTTHARD Server == 102 102 103 103 The server for GOTTHARD (FLASH2) runs on **hasfl2det01**. Its watchdog and control (svr.GOTTHARD) can be found under** FLASH.SYSTEMS - HASFL2DET01.** 126 + 127 +\\ 128 + 129 +== Main Parameters and limits == 130 + 131 +(% class="wrapped" %) 132 +|=((( 133 +Parameter 134 +)))|=((( 135 +Design 136 +)))|=(% colspan="1" %)((( 137 +Real /tested 138 +))) 139 +|((( 140 +Max Frames 141 +)))|((( 142 +125 143 +)))|(% colspan="1" %)((( 144 +120 145 +))) 146 +|((( 147 +Max. exposition time 148 +)))|((( 149 +~~2/3 of period time 150 +)))|(% colspan="1" %)((( 151 +\\ 152 +))) 153 +|((( 154 +Min. period time 155 +)))|((( 156 +ca. 930 ns 157 +)))|(% colspan="1" %)((( 158 +\\ 159 +))) 160 +|((( 161 +Max repetition frequ. 162 +)))|((( 163 +1 MHz 164 +)))|(% colspan="1" %)((( 165 +833 kHz (software limited) 166 +))) 167 + 168 +\\ 169 + 170 +== Soft reset a GOTTHARD Module == 171 + 172 +(% style="list-style-type: square;" %) 173 +* Open console on Linux PC (connected to DESY net) 174 +* write "telnet cfeld-gotthard02" (or the respective Host name or IP of the module) 175 +(% style="list-style-type: square;" %) 176 +** you should be connected to the GOTTHARD onboard system → </root: 177 +* type: "reboot" 178 +(% style="list-style-type: square;" %) 179 +** the module reboots (wait ~~1-2 min), the telnat connection will be cut due to reboot. 180 + 181 +\\ 182 + 183 +== Triggering the Gotthard with a burst trigger == 184 + 185 +it is also possible to trigger the Gotthard not only with 10 Hz but with a burst trigger 186 + 187 +here are some Info from PIS (June 2023) 188 + 189 + 190 + 191 +{{view-file att--filename="Flash_G1.pdf" height="250"/}} 192 + 193 +I think one does not need to set it in GUI when running in continuous mode. In G1, whether the detector is running in burst or continuous mode depends on the setting of the "number of frames" in trigger mode. If the number of frames sets to 1, it will be in continuous mode (1 trigger -> 1 frame). 194 + 195 +Since G1 accepts triggers from the lemo connector, one can also use the bunch train trigger. The spacing of the trigger train needs to be larger than 3.2 ms, which is the readout time of G1. 196 + 197 +Regarding the detector setting (assuming it is 200 kHz pulse rate, 100 pulses per train): 198 + 199 +* timing mode: trigger 200 +* number of frames: 1 201 +* number of triggers: M x N (M is the number of trains and N is the pulses per train, one can also take a bit more frames per train to track the pedestal/dark) 202 +* period: < 5 us (1/200 kHz = 5 us, the period needs to be slightly smaller than 5 us since the detection of the trigger only starts after the period is reached) 203 +* exposure time: > 93 ns and smaller than period 204 + 205 +Alignment: One of the four lemo connectors on G1 outputs its exposure window. Using an oscilloscope, one can use a photodiode under the beam and align the pulses from the diode and the exposure window of G1 by fine tuning the exposure time of G1 and/or the setting of "delay after trigger" from the detector, or "delay time" of the wave-generator (if a wave-generator is used to generate the triggers for every pulse). After this, one can do a fine scan of trigger delay to find an optimal setting with highest signal after putting G1 under the beam. 206 + 207 +\\ 208 + 209 +by: 210 + 211 +Dr. Jiaguo Zhang 212 + 213 +Paul Scherrer Institut 214 + 215 +Forschungsstrasse 111 216 + 217 +5232 Villigen PSI 218 + 219 +Switzerland 220 + 221 +\\ 222 + 223 +\\