1 | * [[LINK to detailled infos from MSK~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://mskwiki/index.php?title=BAM-DAQ_Channels||shape="rect"]] | ||
2 | |||
3 | \\ | ||
4 | |||
5 | * the relevant data is the Arrivaltime FLASH.SDIAG/BAM/4DBC3/LOW_CHARGE_ARRIVAL_TIME | ||
6 | |||
7 | \\ | ||
8 | |||
9 | * There are now (since March 2017) LOW and HIGH charge channels. for now the LOW_CHARGE Channel is the relavant one. | ||
10 | |||
11 | \\ | ||
12 | |||
13 | * bigger numbers indicate later arrivaltime of the electrons | ||
14 | |||
15 | \\ | ||
16 | |||
17 | * the arrivaltime sould be within -20 ps and +20 ps . otherwise there might be a problem ... | ||
18 | |||
19 | \\ | ||
20 | |||
21 | * There is a BAM status parameter: FLASH.SDIAG/BAM/4DBC3/BAM_STATUS.1 (the 1 indicates FLASH1) | ||
22 | ** bit 0 (value: 1) = data is valid, | ||
23 | ** bit 1 (value: 2) = at least 1 bunch is present, | ||
24 | ** bit 2 (value: 4) = calibration is on, | ||
25 | ** bit 3 (value: 8) = internal feedback is on, | ||
26 | ** bit 4 (value: 16) = tuning mode is on | ||
27 | |||
28 | \\ | ||
29 | |||
30 | * if DBC3 is not working then also 3DBC2 can be used. there is a linear correlation between BC2 and BC3 | ||
31 | |||
32 | (from Marie: der groesste Drift-Beitrag kommt immer aus dem Injektor (also alles zw. Injektorlaser und ACC39) Einfluss von ACC23 ist deutlich kleiner. Im Mittel hat man einen linearen Zusammenhang zw. Ankunftszeit BC2 zu BC3.) | ||
33 | |||
34 | \\ | ||
35 | |||
36 | \\ | ||
37 | |||
38 | === more Info: === | ||
39 | |||
40 | \\ | ||
41 | |||
42 | * [[talk by Marie (2011)>>attach:FLASH-seminar-2011_BAM_study_results.pdf]] | ||
43 | * contact: Marie Kristin Czwalinna | ||
44 | |||
45 | \\ | ||
46 | |||
47 | == Streak camera info == | ||
48 | |||
49 | \\ | ||