Changes for page Detectors
Last modified by fwilde on 2024/01/12 12:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,13 +8,13 @@ 8 8 )))|=(% style="text-align: center;width: 22.957%;" %)((( 9 9 KIT CMOS 10 10 )))|=(% style="text-align: center;width: 21.1828%;" %)((( 11 -PCO edge 4.2 11 +(PCO edge 4.2) 12 12 )))|=(% style="width: 4.83871%;text-align: center;" %)((( 13 -Ximea CB500MG-CM 13 +(Ximea CB500MG-CM) 14 14 )))|=(% style="width: 4.78495%;text-align: center;" %)((( 15 15 Ximea CB120MG-CM 16 16 )))|=(% style="width: 1.55914%;text-align: center;" %)((( 17 -XIMEA GSENS6060 17 +(XIMEA GSENS6060) 18 18 ))) 19 19 |(% style="width: 23.9247%;" colspan="2" %)((( 20 20 Sensor ... ... @@ -104,9 +104,9 @@ 104 104 )))|(% style="width: 4.83871%;text-align: center;" %)((( 105 105 7.29 x 5.52 mm 106 106 )))|(% style="width: 4.78495%;text-align: center;" %)((( 107 - \\107 +4.51 x 3.38 mm 108 108 )))|(% style="width: 1.55914%;text-align: center;" %)((( 109 - \\109 +12.28 x 12.28 mm 110 110 ))) 111 111 |(% style="width: 13.5484%;" %)((( 112 112 eff. px size ... ... @@ -119,9 +119,9 @@ 119 119 )))|(% style="width: 4.83871%;text-align: center;" %)((( 120 120 0.9 µm 121 121 )))|(% style="width: 4.78495%;text-align: center;" %)((( 122 - \\122 +1.1 µm 123 123 )))|(% style="width: 1.55914%;text-align: center;" %)((( 124 - \\124 +2 µm 125 125 ))) 126 126 |(% style="width: 10.3763%;" rowspan="2" %)((( 127 127 10x Magn ... ... @@ -136,9 +136,9 @@ 136 136 )))|(% style="width: 4.83871%;text-align: center;" %)((( 137 137 3.64 x 2.76 mm 138 138 )))|(% style="width: 4.78495%;text-align: center;" %)((( 139 - \\139 +2.25 x 1.69 mm 140 140 )))|(% style="width: 1.55914%;text-align: center;" %)((( 141 - \\141 +6.14 x 6.14 mm 142 142 ))) 143 143 |(% style="width: 13.5484%;" %)((( 144 144 eff. px size ... ... @@ -151,9 +151,9 @@ 151 151 )))|(% style="width: 4.83871%;text-align: center;" %)((( 152 152 0.46 µm 153 153 )))|(% style="width: 4.78495%;text-align: center;" %)((( 154 - \\154 +0.55 µm 155 155 )))|(% style="width: 1.55914%;text-align: center;" %)((( 156 - \\156 +1 µm 157 157 ))) 158 158 |(% style="width: 10.3763%;" rowspan="2" %)((( 159 159 20x Magn ... ... @@ -168,9 +168,9 @@ 168 168 )))|(% style="width: 4.83871%;text-align: center;" %)((( 169 169 1.82 x 1.38 mm 170 170 )))|(% style="width: 4.78495%;text-align: center;" %)((( 171 - \\171 +1.13 x 0.84 mm 172 172 )))|(% style="width: 1.55914%;text-align: center;" %)((( 173 - \\173 +3.07 x 3.07 mm 174 174 ))) 175 175 |(% style="width: 13.5484%;" %)((( 176 176 eff. px size ... ... @@ -183,9 +183,9 @@ 183 183 )))|(% style="width: 4.83871%;text-align: center;" %)((( 184 184 0.23 µm 185 185 )))|(% style="width: 4.78495%;text-align: center;" %)((( 186 - \\186 +0.28 µm 187 187 )))|(% style="width: 1.55914%;text-align: center;" %)((( 188 - \\188 +0.5 µm 189 189 ))) 190 190 |(% style="width: 10.3763%;" rowspan="2" %)((( 191 191 40x Magn ... ... @@ -200,9 +200,9 @@ 200 200 )))|(% style="width: 4.83871%;text-align: center;" %)((( 201 201 0.91 x 0.69 mm 202 202 )))|(% style="width: 4.78495%;text-align: center;" %)((( 203 - \\203 +0.56 x 0.42 mm 204 204 )))|(% style="width: 1.55914%;text-align: center;" %)((( 205 - \\205 +1.54 x1.54 mm 206 206 ))) 207 207 |(% style="width: 13.5484%;" %)((( 208 208 eff. px size ... ... @@ -215,15 +215,21 @@ 215 215 )))|(% style="width: 4.83871%;text-align: center;" %)((( 216 216 0.11 µm 217 217 )))|(% style="width: 4.78495%;text-align: center;" %)((( 218 - \\218 +0.14 µm 219 219 )))|(% style="width: 1.55914%;text-align: center;" %)((( 220 - \\220 +0.25 µm 221 221 ))) 222 222 223 -\\ 223 +{{info}} 224 +The PCO edge and all Ximea detectors are in commissioning and will be released to user operation soon. (Detectors in brackets are not yet in user operation). 225 +{{/info}} 224 224 225 225 {{info}} 226 226 The magnification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly. 227 227 228 -** Due to the resolving power of the microscopethe spatial resolutionof the system islimited to ~~1µm, regardless of the effective pixel size!**230 +**The resolving power of the microscope is limited to ~~1µm, regardless of the effective pixel size!** 229 229 {{/info}} 232 + 233 +{{info}} 234 +The speed of each camera can be enhanced by using lower digitalization modes and / or setting ROIs or binning. **If you need faster image acquisition, please contact the beamline staff**. 235 +{{/info}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -13 79960281 +153511035 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/13 7996028/Detectors1 +https://confluence.desy.de/spaces/P5I/pages/153511035/Detectors