Changes for page Detectors
Last modified by fwilde on 2024/01/12 12:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,6 @@ 1 -{{layout}} 2 -{{layout-section ac:type="two_right_sidebar"}} 3 -{{layout-cell}} 4 -= {{id name="Detectors-Overview"/}}Overview = 1 +Availabe detectors with properties in conjunction with the optical microscope. 5 5 6 -(% class="relative-table" style="width: 62.5109%;" %)3 +(% class="relative-table wrapped" style="width: 91.54316%;" %) 7 7 |=(% colspan="2" %)((( 8 8 \\ 9 9 )))|=(% style="text-align: center;" %)((( ... ... @@ -139,107 +139,10 @@ 139 139 0.16 µm 140 140 ))) 141 141 142 -The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly. 143 - 144 144 \\ 145 145 146 -= {{id name="Detectors-EHDSC09000CCDcamera"/}}EHD SC09000 CCD camera = 141 +{{info}} 142 +The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly. 147 147 148 -There are two EHD SciCam SC09000 scientific CCD cameras at P05. One has an integrated 65 mm shutter (currently only the housing, since the shutter was deinstalled) and one without a shutter. 149 - 150 -(% class="relative-table wrapped" style="width: 57.8859%;" %) 151 -|=((( 152 -Parameter 153 -)))|=((( 154 -Value 155 -))) 156 -|((( 157 -Sensor 158 -)))|((( 159 -KAF-09000 160 -))) 161 -|((( 162 -Chip size 163 -)))|((( 164 -(% class="content-wrapper" %) 165 -((( 166 -3056 x 3056 pixel 167 -))) 168 -))) 169 -|((( 170 -Pixel size 171 -)))|((( 172 -12 µm 173 -))) 174 -|((( 175 -Chip diagonal 176 -)))|((( 177 -51.9 mm 178 -))) 179 -|((( 180 -Linear Full Well 181 -)))|((( 182 -110000 e^^-^^ 183 -))) 184 -|((( 185 -PQE 186 -)))|((( 187 -68% 188 -))) 189 -|((( 190 -Interface 191 -)))|((( 192 -USB 2.0 193 -))) 194 -|((( 195 -Digital Resolution 196 -)))|((( 197 -16 Bit 198 -))) 199 -|((( 200 -Max. readout speed 201 -)))|((( 202 -1 MHz, 8 MHz 203 -))) 204 -|((( 205 -Typ. System noise 206 -)))|((( 207 -9e^^-^^ rms @ 1 MHz 208 -))) 209 -|((( 210 -Typ. Max Cooling Temp. 211 -)))|((( 212 -50°C below ambient 213 -))) 214 -|((( 215 -Typ. dark current 216 -)))|((( 217 -<0.01 e^^-^^/pixel/s @ -35°C 218 -))) 219 -|((( 220 -Temp. stability 221 -)))|((( 222 -0.1 °C 223 -))) 224 -|((( 225 -CCD to flange distance 226 -)))|((( 227 -24.96mm (Version with shutter), 19.51mm (Version without shuter) 228 -))) 229 - 230 -== {{id name="Detectors-DetailedKAF09000sensorspecifications"/}}Detailed KAF 09000 sensor specifications == 231 - 232 -{{view-file att--filename="ccd_9000.pdf" display="thumbnail" height="150"/}} 233 - 234 -== {{id name="Detectors-CameraHousingDrawings"/}}Camera Housing Drawings == 235 - 236 -{{view-file att--filename="ML_65MM_AC-D-1.pdf" display="thumbnail" height="150"/}}{{view-file att--filename="ML_65mm(NS)_AC-D-1.pdf" display="thumbnail" height="150"/}} 237 -{{/layout-cell}} 238 - 239 -{{layout-cell}} 240 - 241 - 242 -{{toc/}} 243 -{{/layout-cell}} 244 -{{/layout-section}} 245 -{{/layout}} 144 +**Due to the resolving power of the microscope the spatial resolution of the system is limited to ~~1µm, regardless of the effictive pixel size!** 145 +{{/info}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 - 843154521 +137996014 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/ 84315452/Detectors1 +https://confluence.desy.de/spaces/P5I/pages/137996014/Detectors