Changes for page Detectors

Last modified by fwilde on 2024/01/12 12:00

From version 4.1
edited by fwilde
on 2018/02/01 11:37
Change comment: There is no comment for this version
To version 12.1
edited by fwilde
on 2018/02/01 14:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,6 @@
1 -{{layout}}
2 -{{layout-section ac:type="two_right_sidebar"}}
3 -{{layout-cell}}
4 -= {{id name="Detectors-Overview"/}}Overview =
1 +Availabe detectors with properties in conjunction with the optical microscope.
5 5  
6 -(% class="relative-table" style="width: 62.5109%;" %)
3 +(% class="relative-table wrapped" style="width: 91.54316%;" %)
7 7  |=(% colspan="2" %)(((
8 8  \\
9 9  )))|=(% style="text-align: center;" %)(((
... ... @@ -139,107 +139,10 @@
139 139  0.16 µm
140 140  )))
141 141  
142 -The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly.
143 -
144 144  \\
145 145  
146 -= {{id name="Detectors-EHDSC09000CCDcamera"/}}EHD SC09000 CCD camera =
141 +{{info}}
142 +The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly.
147 147  
148 -There are two EHD SciCam SC09000 scientific CCD cameras at P05. One has an integrated 65 mm shutter (currently only the housing, since the shutter was deinstalled) and one without a shutter.
149 -
150 -(% class="relative-table wrapped" style="width: 57.8859%;" %)
151 -|=(((
152 -Parameter
153 -)))|=(((
154 -Value
155 -)))
156 -|(((
157 -Sensor
158 -)))|(((
159 -KAF-09000
160 -)))
161 -|(((
162 -Chip size
163 -)))|(((
164 -(% class="content-wrapper" %)
165 -(((
166 -3056 x 3056 pixel
167 -)))
168 -)))
169 -|(((
170 -Pixel size
171 -)))|(((
172 -12 µm
173 -)))
174 -|(((
175 -Chip diagonal
176 -)))|(((
177 -51.9 mm
178 -)))
179 -|(((
180 -Linear Full Well
181 -)))|(((
182 -110000 e^^-^^
183 -)))
184 -|(((
185 -PQE
186 -)))|(((
187 -68%
188 -)))
189 -|(((
190 -Interface
191 -)))|(((
192 -USB 2.0
193 -)))
194 -|(((
195 -Digital Resolution
196 -)))|(((
197 -16 Bit
198 -)))
199 -|(((
200 -Max. readout speed
201 -)))|(((
202 -1 MHz, 8 MHz
203 -)))
204 -|(((
205 -Typ. System noise
206 -)))|(((
207 -9e^^-^^ rms @ 1 MHz
208 -)))
209 -|(((
210 -Typ. Max Cooling Temp.
211 -)))|(((
212 -50°C below ambient
213 -)))
214 -|(((
215 -Typ. dark current
216 -)))|(((
217 -<0.01 e^^-^^/pixel/s @ -35°C
218 -)))
219 -|(((
220 -Temp. stability
221 -)))|(((
222 -0.1 °C
223 -)))
224 -|(((
225 -CCD to flange distance
226 -)))|(((
227 -24.96mm (Version with shutter),  19.51mm (Version without shuter)
228 -)))
229 -
230 -== {{id name="Detectors-DetailedKAF09000sensorspecifications"/}}Detailed KAF 09000 sensor specifications ==
231 -
232 -{{view-file att--filename="ccd_9000.pdf" display="thumbnail" height="150"/}}
233 -
234 -== {{id name="Detectors-CameraHousingDrawings"/}}Camera Housing Drawings ==
235 -
236 -{{view-file att--filename="ML_65MM_AC-D-1.pdf" display="thumbnail" height="150"/}}{{view-file att--filename="ML_65mm(NS)_AC-D-1.pdf" display="thumbnail" height="150"/}}
237 -{{/layout-cell}}
238 -
239 -{{layout-cell}}
240 -
241 -
242 -{{toc/}}
243 -{{/layout-cell}}
244 -{{/layout-section}}
245 -{{/layout}}
144 +**Due to the resolving power of the microscope the spatial resolution of the system is limited to ~~1µm, regardless of the effictive pixel size!**
145 +{{/info}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -84315452
1 +137996014
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/P5I/pages/84315452/Detectors
1 +https://confluence.desy.de/spaces/P5I/pages/137996014/Detectors