Changes for page Detectors

Last modified by fwilde on 2024/01/12 12:00

From version 5.1
edited by fwilde
on 2018/02/01 11:41
Change comment: There is no comment for this version
To version 10.1
edited by fwilde
on 2018/02/01 11:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,13 +1,6 @@
1 -{{info}}{{/info}}
1 +Availabe detectors with properties in conjunction with the optical microscope.
2 2  
3 -{{layout}}
4 -{{layout-section ac:type="two_right_sidebar"}}
5 -{{layout-cell}}
6 -\\
7 -
8 -= {{id name="Detectors-Overview"/}}Overview =
9 -
10 -(% class="relative-table" style="width: 62.5109%;" %)
3 +(% class="relative-table wrapped" style="width: 91.54316%;" %)
11 11  |=(% colspan="2" %)(((
12 12  \\
13 13  )))|=(% style="text-align: center;" %)(((
... ... @@ -143,107 +143,10 @@
143 143  0.16 µm
144 144  )))
145 145  
146 -The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly.
147 -
148 148  \\
149 149  
150 -= {{id name="Detectors-EHDSC09000CCDcamera"/}}EHD SC09000 CCD camera =
141 +{{info}}
142 +The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly.
151 151  
152 -There are two EHD SciCam SC09000 scientific CCD cameras at P05. One has an integrated 65 mm shutter (currently only the housing, since the shutter was deinstalled) and one without a shutter.
153 -
154 -(% class="relative-table wrapped" style="width: 57.8859%;" %)
155 -|=(((
156 -Parameter
157 -)))|=(((
158 -Value
159 -)))
160 -|(((
161 -Sensor
162 -)))|(((
163 -KAF-09000
164 -)))
165 -|(((
166 -Chip size
167 -)))|(((
168 -(% class="content-wrapper" %)
169 -(((
170 -3056 x 3056 pixel
171 -)))
172 -)))
173 -|(((
174 -Pixel size
175 -)))|(((
176 -12 µm
177 -)))
178 -|(((
179 -Chip diagonal
180 -)))|(((
181 -51.9 mm
182 -)))
183 -|(((
184 -Linear Full Well
185 -)))|(((
186 -110000 e^^-^^
187 -)))
188 -|(((
189 -PQE
190 -)))|(((
191 -68%
192 -)))
193 -|(((
194 -Interface
195 -)))|(((
196 -USB 2.0
197 -)))
198 -|(((
199 -Digital Resolution
200 -)))|(((
201 -16 Bit
202 -)))
203 -|(((
204 -Max. readout speed
205 -)))|(((
206 -1 MHz, 8 MHz
207 -)))
208 -|(((
209 -Typ. System noise
210 -)))|(((
211 -9e^^-^^ rms @ 1 MHz
212 -)))
213 -|(((
214 -Typ. Max Cooling Temp.
215 -)))|(((
216 -50°C below ambient
217 -)))
218 -|(((
219 -Typ. dark current
220 -)))|(((
221 -<0.01 e^^-^^/pixel/s @ -35°C
222 -)))
223 -|(((
224 -Temp. stability
225 -)))|(((
226 -0.1 °C
227 -)))
228 -|(((
229 -CCD to flange distance
230 -)))|(((
231 -24.96mm (Version with shutter),  19.51mm (Version without shuter)
232 -)))
233 -
234 -== {{id name="Detectors-DetailedKAF09000sensorspecifications"/}}Detailed KAF 09000 sensor specifications ==
235 -
236 -{{view-file att--filename="ccd_9000.pdf" display="thumbnail" height="150"/}}
237 -
238 -== {{id name="Detectors-CameraHousingDrawings"/}}Camera Housing Drawings ==
239 -
240 -{{view-file att--filename="ML_65MM_AC-D-1.pdf" display="thumbnail" height="150"/}}{{view-file att--filename="ML_65mm(NS)_AC-D-1.pdf" display="thumbnail" height="150"/}}
241 -{{/layout-cell}}
242 -
243 -{{layout-cell}}
244 -
245 -
246 -{{toc/}}
247 -{{/layout-cell}}
248 -{{/layout-section}}
249 -{{/layout}}
144 +**Due to the resolving power of the microscope the optical resolution of the system is limited to ~~1µm, regardless the effictive pixel size!**
145 +{{/info}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -84315456
1 +84315648
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/P5I/pages/84315456/Detectors
1 +https://confluence.desy.de/spaces/P5I/pages/84315648/Detectors