Changes for page Detectors
Last modified by fwilde on 2024/01/12 12:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,13 +1,6 @@ 1 - {{info}}{{/info}}1 +Availabe detectors with properties in conjunction with the optical microscope. 2 2 3 -{{layout}} 4 -{{layout-section ac:type="two_right_sidebar"}} 5 -{{layout-cell}} 6 -\\ 7 - 8 -= {{id name="Detectors-Overview"/}}Overview = 9 - 10 -(% class="relative-table" style="width: 62.5109%;" %) 3 +(% class="relative-table wrapped" style="width: 91.54316%;" %) 11 11 |=(% colspan="2" %)((( 12 12 \\ 13 13 )))|=(% style="text-align: center;" %)((( ... ... @@ -143,107 +143,10 @@ 143 143 0.16 µm 144 144 ))) 145 145 146 -The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly. 147 - 148 148 \\ 149 149 150 -= {{id name="Detectors-EHDSC09000CCDcamera"/}}EHD SC09000 CCD camera = 141 +{{info}} 142 +The magification values may vary about +/-5%. Thus the FOV and eff. pix. sizes vary accordingly. 151 151 152 -There are two EHD SciCam SC09000 scientific CCD cameras at P05. One has an integrated 65 mm shutter (currently only the housing, since the shutter was deinstalled) and one without a shutter. 153 - 154 -(% class="relative-table wrapped" style="width: 57.8859%;" %) 155 -|=((( 156 -Parameter 157 -)))|=((( 158 -Value 159 -))) 160 -|((( 161 -Sensor 162 -)))|((( 163 -KAF-09000 164 -))) 165 -|((( 166 -Chip size 167 -)))|((( 168 -(% class="content-wrapper" %) 169 -((( 170 -3056 x 3056 pixel 171 -))) 172 -))) 173 -|((( 174 -Pixel size 175 -)))|((( 176 -12 µm 177 -))) 178 -|((( 179 -Chip diagonal 180 -)))|((( 181 -51.9 mm 182 -))) 183 -|((( 184 -Linear Full Well 185 -)))|((( 186 -110000 e^^-^^ 187 -))) 188 -|((( 189 -PQE 190 -)))|((( 191 -68% 192 -))) 193 -|((( 194 -Interface 195 -)))|((( 196 -USB 2.0 197 -))) 198 -|((( 199 -Digital Resolution 200 -)))|((( 201 -16 Bit 202 -))) 203 -|((( 204 -Max. readout speed 205 -)))|((( 206 -1 MHz, 8 MHz 207 -))) 208 -|((( 209 -Typ. System noise 210 -)))|((( 211 -9e^^-^^ rms @ 1 MHz 212 -))) 213 -|((( 214 -Typ. Max Cooling Temp. 215 -)))|((( 216 -50°C below ambient 217 -))) 218 -|((( 219 -Typ. dark current 220 -)))|((( 221 -<0.01 e^^-^^/pixel/s @ -35°C 222 -))) 223 -|((( 224 -Temp. stability 225 -)))|((( 226 -0.1 °C 227 -))) 228 -|((( 229 -CCD to flange distance 230 -)))|((( 231 -24.96mm (Version with shutter), 19.51mm (Version without shuter) 232 -))) 233 - 234 -== {{id name="Detectors-DetailedKAF09000sensorspecifications"/}}Detailed KAF 09000 sensor specifications == 235 - 236 -{{view-file att--filename="ccd_9000.pdf" display="thumbnail" height="150"/}} 237 - 238 -== {{id name="Detectors-CameraHousingDrawings"/}}Camera Housing Drawings == 239 - 240 -{{view-file att--filename="ML_65MM_AC-D-1.pdf" display="thumbnail" height="150"/}}{{view-file att--filename="ML_65mm(NS)_AC-D-1.pdf" display="thumbnail" height="150"/}} 241 -{{/layout-cell}} 242 - 243 -{{layout-cell}} 244 - 245 - 246 -{{toc/}} 247 -{{/layout-cell}} 248 -{{/layout-section}} 249 -{{/layout}} 144 +**Due to the resolving power of the microscope the optical resolution of the system is limited to ~~1µm, regardless the effictive pixel size!** 145 +{{/info}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -84315 4561 +84315648 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/84315 456/Detectors1 +https://confluence.desy.de/spaces/P5I/pages/84315648/Detectors