Changes for page Load frame
Last modified by fwilde on 2023/10/12 12:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +3,8 @@ 1 -== {{id name="Loadframe-TOC"/}}TOC == 2 - 3 3 == {{id name="Loadframe-"/}} == 4 4 5 5 {{toc/}} 6 6 7 -= ={{id name="Loadframe-Overview"/}}Overview ==5 += {{id name="Loadframe-Overview"/}}Overview = 8 8 9 9 [[image:attach:DSC_0006.JPG||width="400"]] 10 10 ... ... @@ -12,7 +12,7 @@ 12 12 * Load cells 20N, 50N, 100N, 200N, 500N and 1000N available 13 13 * Fully integrated into control and logging system 14 14 15 -= ={{id name="Loadframe-Actuator"/}}Actuator ==13 += {{id name="Loadframe-Actuator"/}}Actuator = 16 16 17 17 [[image:attach:DSC_0020.JPG||height="250"]][[image:attach:DSC_0021.JPG||height="250"]] 18 18 ... ... @@ -56,7 +56,7 @@ 56 56 ))) 57 57 ))) 58 58 59 -= ={{id name="Loadframe-Loadcells"/}}Load cells ==57 += {{id name="Loadframe-Loadcells"/}}Load cells = 60 60 61 61 Two types of load cells are available with different diameters with the following force range 62 62 ... ... @@ -108,7 +108,7 @@ 108 108 thread: M4 (max len 5 mm) 109 109 ))) 110 110 111 -= ={{id name="Loadframe-Loadframeassembly"/}}Load frame assembly ==109 += {{id name="Loadframe-Loadframeassembly"/}}Load frame assembly = 112 112 113 113 Considering different applications (high forces, low forces, pushing or pulling) the assembly follows slightly different paths. Generally, assembling the load frame can be broken down into these steps: 114 114 ... ... @@ -117,7 +117,7 @@ 117 117 * Mount sample tube (choose the tube type according to your application) 118 118 * Mount pusher 119 119 120 -== ={{id name="Loadframe-Largeloadcellinstallation"/}}Large load cell installation ===118 +== {{id name="Loadframe-Largeloadcellinstallation"/}}Large load cell installation == 121 121 122 122 For the large load cell a specific base plate has to be used 123 123 ... ... @@ -141,7 +141,7 @@ 141 141 142 142 Mount bridge and guide - there are two different types of tube, so assembly depends on your choice of tube: 143 143 144 -=== ={{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ====142 +=== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring === 145 145 146 146 (% class="wrapped" %) 147 147 |(% style="text-align: center;" %)((( ... ... @@ -168,7 +168,7 @@ 168 168 Tube with thread ring 169 169 ))) 170 170 171 -=== ={{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ====169 +=== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread === 172 172 173 173 (% class="wrapped" %) 174 174 |(% style="text-align: center;" %)((( ... ... @@ -195,7 +195,7 @@ 195 195 Tube with internal thread 196 196 ))) 197 197 198 -== ={{id name="Loadframe-Smallloadcellinstallation"/}}Small load cell installation ===196 +== {{id name="Loadframe-Smallloadcellinstallation"/}}Small load cell installation == 199 199 200 200 For the small load cell a specific base plate has to be used 201 201 ... ... @@ -219,7 +219,7 @@ 219 219 220 220 Mount pin guide and bridge - there are two different types of tube, so assembly depends on your choice of tube: 221 221 222 -=== ={{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ====220 +=== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring === 223 223 224 224 (% class="wrapped" %) 225 225 |((( ... ... @@ -239,7 +239,7 @@ 239 239 Tube with thread ring 240 240 ))) 241 241 242 -=== ={{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ====240 +=== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread === 243 243 244 244 (% class="wrapped" %) 245 245 |(% style="text-align: center;" %)((( ... ... @@ -273,14 +273,83 @@ 273 273 Tube with internal thread 274 274 ))) 275 275 276 -= ={{id name="Loadframe-Samplemounting"/}}Samplemounting==274 += {{id name="Loadframe-Tubes"/}}Tubes = 277 277 276 +{{info title="Tubes"}} 277 +There are different tubes available at the beamline. Should the tube be unsuitable for your sample, a new tube can be manufactured. Please contact the beamline staff well in advance of your beamtime. 278 +{{/info}} 279 + 280 +(% class="wrapped" %) 281 +|(% style="text-align: center;" %)((( 282 +(% class="content-wrapper" %) 283 +((( 284 +[[image:attach:DSC_0028.JPG||height="250"]] 285 +))) 286 +))) 287 +|(% style="text-align: center;" %)((( 288 +Different Tubes with lengths of ~~80 mm and 140 mm 289 +))) 290 + 291 += {{id name="Loadframe-Samplemounting"/}}Sample mounting = 292 + 278 278 {{info title="Pins and clamps"}} 279 279 Depending on your application, sample installation may vary. There are a selection of pushing pins and pulling clamps available at the beamline which will be presented in this section. Nevertheless these pins or clamps may be unsuitable for your sample. In this case a suitable pin or clamp can be manufactured. Please contact the beamline staff well in advance of your beamtime. 280 280 {{/info}} 281 281 282 -== {{id name="Loadframe-Reference"/}}Reference == 297 +(% class="wrapped" %) 298 +|=(% colspan="2" %)((( 299 +Pushing 300 +)))|=(% colspan="2" %)((( 301 +Pulling 302 +))) 303 +|((( 304 +Bottom push pin 305 +)))|((( 306 +(% class="content-wrapper" %) 307 +((( 308 +[[image:attach:DSC_0045.JPG||height="250"]] 309 +))) 310 +)))|((( 311 +Bottom pull thread 312 +)))|((( 313 +(% class="content-wrapper" %) 314 +((( 315 +[[image:attach:DSC_0041.JPG||height="250"]] 316 +))) 317 +))) 318 +|((( 319 +Top push pin 320 +)))|((( 321 +(% class="content-wrapper" %) 322 +((( 323 +[[image:attach:DSC_0047.JPG||height="250"]] 324 +))) 325 +)))|((( 326 +Principle of pull installation 327 +)))|((( 328 +(% class="content-wrapper" %) 329 +((( 330 +[[image:attach:DSC_0049.JPG||height="250"]] 331 +))) 332 +))) 333 +|((( 334 +Top push pin 335 +)))|((( 336 +(% class="content-wrapper" %) 337 +((( 338 +[[image:attach:DSC_0048.JPG||height="250"]] 339 +))) 340 +)))|((( 341 +Pull clamps for low forces 342 +)))|((( 343 +(% class="content-wrapper" %) 344 +((( 345 +[[image:attach:DSC_0050.JPG||thumbnail="true" height="250"]] 346 +))) 347 +))) 283 283 349 += {{id name="Loadframe-Reference"/}}Reference = 350 + 284 284 Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]] 285 285 286 286 \\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -32697557 01 +326975578 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/32697557 0/Load frame1 +https://confluence.desy.de/spaces/P5I/pages/326975578/Load frame