Changes for page Load frame

Last modified by fwilde on 2023/10/12 12:40

From version 25.1
edited by fwilde
on 2023/10/12 12:20
Change comment: There is no comment for this version
To version 18.1
edited by fwilde
on 2023/10/05 18:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,18 +1,18 @@
1 +== {{id name="Loadframe-TOC"/}}TOC ==
1 1  
3 +== {{id name="Loadframe-"/}} ==
2 2  
3 3  {{toc/}}
4 4  
5 -= {{id name="Loadframe-Overview"/}}Overview =
7 +== {{id name="Loadframe-Overview"/}}Overview ==
6 6  
7 7  [[image:attach:DSC_0006.JPG||width="400"]]
8 8  
9 -\\
10 -
11 11  * Forces up to 1 kN (both pushing or pulling)
12 12  * Load cells 20N, 50N, 100N, 200N, 500N and 1000N available
13 13  * Fully integrated into control and logging system
14 14  
15 -= {{id name="Loadframe-Actuator"/}}Actuator =
15 +== {{id name="Loadframe-Actuator"/}}Actuator ==
16 16  
17 17  [[image:attach:DSC_0020.JPG||height="250"]][[image:attach:DSC_0021.JPG||height="250"]]
18 18  
... ... @@ -33,25 +33,30 @@
33 33  ? mm
34 34  )))
35 35  |(((
36 +min speed
37 +)))|(((
38 +? µm/s
39 +)))
40 +|(((
36 36  max. speed
37 37  )))|(((
38 -5000 µm/s
43 +? µm/s
39 39  )))
40 40  |(((
41 41  Step width
42 42  )))|(((
43 -1/20 µm
48 +? µm
44 44  )))
45 45  |(((
46 -fine pitch thread
51 +fine pitch hread
47 47  )))|(((
48 48  (% class="content-wrapper" %)
49 49  (((
50 -M(8 x 1.0) x 45 ???
55 +M8 x 0.5 ???
51 51  )))
52 52  )))
53 53  
54 -= {{id name="Loadframe-Loadcells"/}}Load cells =
59 +== {{id name="Loadframe-Loadcells"/}}Load cells ==
55 55  
56 56  Two types of load cells are available with different diameters with the following force range
57 57  
... ... @@ -100,10 +100,10 @@
100 100  |(((
101 101  thread: M8 (max  len 15 mm)
102 102  )))|(((
103 -thread: M4 (max len 6 mm)
108 +thread: M4 (max len 5 mm)
104 104  )))
105 105  
106 -= {{id name="Loadframe-Loadframeassembly"/}}Load frame assembly =
111 +== {{id name="Loadframe-Loadframeassembly"/}}Load frame assembly ==
107 107  
108 108  Considering different applications (high forces, low forces, pushing or pulling) the assembly follows slightly different paths. Generally, assembling the load frame can be broken down into these steps:
109 109  
... ... @@ -112,7 +112,7 @@
112 112  * Mount sample tube (choose the tube type according to your application)
113 113  * Mount pusher
114 114  
115 -== {{id name="Loadframe-Largeloadcellinstallation"/}}Large load cell installation ==
120 +=== {{id name="Loadframe-Largeloadcellinstallation"/}}Large load cell installation ===
116 116  
117 117  For the large load cell a specific base plate has to be used
118 118  
... ... @@ -131,12 +131,12 @@
131 131  |(% style="text-align: center;" %)(((
132 132  Base plate with load cell
133 133  )))|(% style="text-align: center;" %)(((
134 -Load cell with pin (M5 gaused for pulling
139 +Load cell with pin used for pulling
135 135  )))
136 136  
137 137  Mount bridge and guide - there are two different types of tube, so assembly depends on your choice of tube:
138 138  
139 -=== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ===
144 +==== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ====
140 140  
141 141  (% class="wrapped" %)
142 142  |(% style="text-align: center;" %)(((
... ... @@ -163,7 +163,7 @@
163 163  Tube with thread ring
164 164  )))
165 165  
166 -=== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ===
171 +==== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ====
167 167  
168 168  (% class="wrapped" %)
169 169  |(% style="text-align: center;" %)(((
... ... @@ -190,33 +190,8 @@
190 190  Tube with internal thread
191 191  )))
192 192  
193 -=== {{id name="Loadframe-Pin"/}}Pin ===
198 +=== {{id name="Loadframe-Smallloadcellinstallation"/}}Small load cell installation ===
194 194  
195 -(% class="wrapped" %)
196 -|(% colspan="2" %)(((
197 -(% class="content-wrapper" %)
198 -(((
199 -[[image:attach:loadcell_pin_large.JPG||height="250"]]
200 -)))
201 -)))
202 -|(((
203 -Total length
204 -)))|(((
205 -56 mm
206 -)))
207 -|(((
208 -Thread at load cell
209 -)))|(((
210 -M8 x 6
211 -)))
212 -|(((
213 -Thread top part
214 -)))|(((
215 -M5 x 14
216 -)))
217 -
218 -== {{id name="Loadframe-Smallloadcellinstallation"/}}Small load cell installation ==
219 -
220 220  For the small load cell a specific base plate has to be used
221 221  
222 222  (% class="wrapped" %)
... ... @@ -239,7 +239,7 @@
239 239  
240 240  Mount pin guide and bridge - there are two different types of tube, so assembly depends on your choice of tube:
241 241  
242 -=== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ===
222 +==== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ====
243 243  
244 244  (% class="wrapped" %)
245 245  |(((
... ... @@ -255,15 +255,11 @@
255 255  )))
256 256  |(((
257 257  Pin guide, no bridge necessary
258 -
259 -Distance top load cell - top bridge surface: 23.5mm (+ 6 mm thread of load cell)
260 -
261 -For own
262 262  )))|(((
263 263  Tube with thread ring
264 264  )))
265 265  
266 -=== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ===
242 +==== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ====
267 267  
268 268  (% class="wrapped" %)
269 269  |(% style="text-align: center;" %)(((
... ... @@ -297,38 +297,12 @@
297 297  Tube with internal thread
298 298  )))
299 299  
300 -=== {{id name="Loadframe-Pin"/}}Pin ===
276 +== {{id name="Loadframe-Tubes"/}}Tubes ==
301 301  
302 -(% class="wrapped" %)
303 -|(% colspan="2" %)(((
304 -(% class="content-wrapper" %)
305 -(((
306 -[[image:attach:loadcell_pin_small.JPG||height="250"]]
307 -)))
308 -)))
309 -|(((
310 -Total length
311 -)))|(((
312 -80 mm
313 -)))
314 -|(((
315 -Thread at load cell
316 -)))|(((
317 -M4 x 4
318 -)))
319 -|(((
320 -Thread top part
321 -)))|(((
322 -M5 x 35
323 -)))
324 -
325 -= {{id name="Loadframe-Tubes"/}}Tubes =
326 -
327 327  {{info title="Tubes"}}
328 328  There are different tubes available at the beamline. Should the tube be unsuitable for your sample, a new tube can be manufactured. Please contact the beamline staff well in advance of your beamtime.
329 329  {{/info}}
330 330  
331 -(% class="wrapped" %)
332 332  |(% style="text-align: center;" %)(((
333 333  (% class="content-wrapper" %)
334 334  (((
... ... @@ -339,7 +339,7 @@
339 339  Different Tubes with lengths of ~~80 mm and 140 mm
340 340  )))
341 341  
342 -= {{id name="Loadframe-Samplemounting"/}}Sample mounting =
292 +== {{id name="Loadframe-Samplemounting"/}}Sample mounting ==
343 343  
344 344  {{info title="Pins and clamps"}}
345 345  Depending on your application, sample installation may vary. There are a selection of pushing pins and pulling clamps available at the beamline which will be presented in this section. Nevertheless these pins or clamps may be unsuitable for your sample. In this case a suitable pin or clamp can be manufactured. Please contact the beamline staff well in advance of your beamtime.
... ... @@ -397,7 +397,7 @@
397 397  )))
398 398  )))
399 399  
400 -= {{id name="Loadframe-Reference"/}}Reference =
350 +== {{id name="Loadframe-Reference"/}}Reference ==
401 401  
402 402  Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]]
403 403  
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -326982927
1 +326975573
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/P5I/pages/326982927/Load frame
1 +https://confluence.desy.de/spaces/P5I/pages/326975573/Load frame