Changes for page Load frame

Last modified by fwilde on 2023/10/12 12:40

From version 25.1
edited by fwilde
on 2023/10/12 12:20
Change comment: There is no comment for this version
To version 28.1
edited by fwilde
on 2023/10/12 12:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -190,7 +190,7 @@
190 190  Tube with internal thread
191 191  )))
192 192  
193 -=== {{id name="Loadframe-Pin"/}}Pin ===
193 +=== {{id name="Loadframe-Loadcellpinforpulling"/}}Load cell pin for pulling ===
194 194  
195 195  (% class="wrapped" %)
196 196  |(% colspan="2" %)(((
... ... @@ -214,6 +214,11 @@
214 214  )))|(((
215 215  M5 x 14
216 216  )))
217 +|(((
218 +Pin guide in brigde diameter
219 +)))|(((
220 +6 mm
221 +)))
217 217  
218 218  == {{id name="Loadframe-Smallloadcellinstallation"/}}Small load cell installation ==
219 219  
... ... @@ -297,7 +297,7 @@
297 297  Tube with internal thread
298 298  )))
299 299  
300 -=== {{id name="Loadframe-Pin"/}}Pin ===
305 +=== {{id name="Loadframe-Loadcellpinforpulling"/}}Load cell pin for pulling ===
301 301  
302 302  (% class="wrapped" %)
303 303  |(% colspan="2" %)(((
... ... @@ -321,6 +321,11 @@
321 321  )))|(((
322 322  M5 x 35
323 323  )))
329 +|(((
330 +Pin guide in brigde diameter
331 +)))|(((
332 +6 mm
333 +)))
324 324  
325 325  = {{id name="Loadframe-Tubes"/}}Tubes =
326 326  
... ... @@ -336,7 +336,7 @@
336 336  )))
337 337  )))
338 338  |(% style="text-align: center;" %)(((
339 -Different Tubes with lengths of ~~80 mm and 140 mm
349 +Different Tubes with lengths of 80 mm, 140 mm and 160 mm
340 340  )))
341 341  
342 342  = {{id name="Loadframe-Samplemounting"/}}Sample mounting =
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -326982927
1 +326982947
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/P5I/pages/326982927/Load frame
1 +https://confluence.desy.de/spaces/P5I/pages/326982947/Load frame