Changes for page Load frame
Last modified by fwilde on 2023/10/12 12:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,10 +8,11 @@ 8 8 9 9 == {{id name="Loadframe-Actuator"/}}Actuator == 10 10 11 - The actuator is a customized PiMicos MA-35 actuator with a maximum load of 1000 N.11 +\\ 12 12 13 13 [[image:attach:DSC_0020.JPG||height="250"]][[image:attach:DSC_0021.JPG||height="250"]] 14 14 15 +(% class="wrapped" %) 15 15 |=((( 16 16 PIMicos MA-35 17 17 )))|=((( ... ... @@ -43,17 +43,26 @@ 43 43 ? µm 44 44 ))) 45 45 |((( 46 - Thread47 +fine pitch hread 47 47 )))|((( 49 +(% class="content-wrapper" %) 50 +((( 48 48 M8 x 0.5 ??? 49 49 ))) 53 +))) 50 50 51 51 == {{id name="Loadframe-Loadcells"/}}Load cells == 52 52 53 53 Two types of load cells are available with different diameters with the following force range 54 54 55 -(% class="relative-table" style="width: 8.27815%;" %) 56 -|=((( 59 +(% class="relative-table wrapped" style="width: 23.2261%;" %) 60 +|(% colspan="2" %)((( 61 +(% class="content-wrapper" %) 62 +((( 63 +[[image:attach:DSC_0031.JPG||align="center" height="250"]] 64 +))) 65 +))) 66 +|=(% style="text-align: center;" %)((( 57 57 large 58 58 )))|=(% style="text-align: center;" %)((( 59 59 small ... ... @@ -88,7 +88,99 @@ 88 88 )))|(% style="text-align: center;" %)((( 89 89 1000 N 90 90 ))) 101 +|((( 102 +thread: M8 (max len 15 mm) 103 +)))|((( 104 +thread: M4 (max len 5 mm) 105 +))) 91 91 107 +== {{id name="Loadframe-Loadframeassembly"/}}Load frame assembly == 108 + 109 +Considering different applications (high forces, low forces, pushing or pulling) the assembly follows slightly different paths. Generally, assembling the load frame can be broken down into these steps: 110 + 111 +* Install a base plate on the rotation stage (use spacers, decide which plate to use) 112 +* Mount load cell on base plate with desired pin or clamp (depending on push or pull experiments) 113 +* Mount sample tube (choose the tube type according to your application) 114 +* Mount pusher 115 + 116 +=== {{id name="Loadframe-Largeloadcellinstallation"/}}Large load cell installation === 117 + 118 +For the large load cell a specific base plate has to be used (see image) 119 + 120 +(% class="wrapped" %) 121 +|(% style="text-align: center;" %)((( 122 +(% class="content-wrapper" %) 123 +((( 124 +[[image:attach:DSC_0032.JPG||alt="Base plate with load cell" title="Base plate with load cell" height="250"]] 125 +))) 126 +)))|(% style="text-align: center;" %)((( 127 +(% class="content-wrapper" %) 128 +((( 129 +[[image:attach:DSC_0033.JPG||height="250"]] 130 +))) 131 +))) 132 +|(% style="text-align: center;" %)((( 133 +Base plate with load cell 134 +)))|(% style="text-align: center;" %)((( 135 +Load cell with pin used for pulling 136 +))) 137 + 138 +Mount bridge and guide - there are two different types of tube, so assaembly depends on your choice of tube: 139 + 140 +==== {{id name="Loadframe-Tubewiththreadring"/}}Tube with thread ring ==== 141 + 142 +(% class="wrapped" %) 143 +|(% style="text-align: center;" %)((( 144 +(% class="content-wrapper" %) 145 +((( 146 +[[image:attach:DSC_0034.JPG||height="250"]] 147 +))) 148 +)))|(% style="text-align: center;" %)((( 149 +(% class="content-wrapper" %) 150 +((( 151 +[[image:attach:DSC_0035.JPG||height="250"]] 152 +))) 153 +)))|(% style="text-align: center;" %)((( 154 +(% class="content-wrapper" %) 155 +((( 156 +[[image:attach:DSC_0036.JPG||height="250"]] 157 +))) 158 +))) 159 +|(% style="text-align: center;" %)((( 160 +Bridge 161 +)))|(% style="text-align: center;" %)((( 162 +Brigde and pin guide 163 +)))|(% style="text-align: center;" %)((( 164 +Tube with thread ring 165 +))) 166 + 167 +==== {{id name="Loadframe-Tubewithinternalthread"/}}Tube with internal thread ==== 168 + 169 +(% class="wrapped" %) 170 +|(% style="text-align: center;" %)((( 171 +(% class="content-wrapper" %) 172 +((( 173 +[[image:attach:DSC_0034.JPG||height="250"]] 174 +))) 175 +)))|(% style="text-align: center;" %)((( 176 +(% class="content-wrapper" %) 177 +((( 178 +[[image:attach:DSC_0037.JPG||thumbnail="true" height="250"]] 179 +))) 180 +)))|(% style="text-align: center;" %)((( 181 +(% class="content-wrapper" %) 182 +((( 183 +[[image:attach:DSC_0038.JPG||height="250"]] 184 +))) 185 +))) 186 +|(% style="text-align: center;" %)((( 187 +Bridge 188 +)))|(% style="text-align: center;" %)((( 189 +Bridge and pin guide 190 +)))|(% style="text-align: center;" %)((( 191 +Tube wigth internal thread 192 +))) 193 + 92 92 == {{id name="Loadframe-Reference"/}}Reference == 93 93 94 94 Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]]
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -32697547 51 +326975547 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/32697547 5/Load frame1 +https://confluence.desy.de/spaces/P5I/pages/326975547/Load frame