Changes for page Load frame
Last modified by fwilde on 2023/10/12 12:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,6 @@ 1 1 == {{id name="Loadframe-Overview"/}}Overview == 2 2 3 -[[image:attach:DSC_0006.JPG|| width="400"]]3 +[[image:attach:DSC_0006.JPG||height="400"]] 4 4 5 5 * Forces up to 1 kN (both pushing or pulling) 6 6 * Load cells 20N, 50N, 100N, 200N, 500N and 1000N available ... ... @@ -8,93 +8,8 @@ 8 8 9 9 == {{id name="Loadframe-Actuator"/}}Actuator == 10 10 11 - [[image:attach:DSC_0020.JPG||height="250"]][[image:attach:DSC_0021.JPG||height="250"]]11 +The actuator is a customized PiMicos MA-35 actuator with a maximum load of 1000 N. 12 12 13 -(% class="wrapped" %) 14 -|=((( 15 -PIMicos MA-35 16 -)))|=((( 17 -\\ 18 -))) 19 -|((( 20 -max. load (in travel direction) 21 -)))|((( 22 -1000N 23 -))) 24 -|((( 25 -Travel range 26 -)))|((( 27 -? mm 28 -))) 29 -|((( 30 -min speed 31 -)))|((( 32 -? µm/s 33 -))) 34 -|((( 35 -max. speed 36 -)))|((( 37 -? µm/s 38 -))) 39 -|((( 40 -Step width 41 -)))|((( 42 -? µm 43 -))) 44 -|((( 45 -Thread 46 -)))|((( 47 -M8 x 0.5 ??? 48 -))) 13 +More information: Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]] 49 49 50 -== {{id name="Loadframe-Loadcells"/}}Load cells == 51 - 52 -Two types of load cells are available with different diameters with the following force range 53 - 54 -(% class="relative-table wrapped" style="width: 19.0161%;" %) 55 -|(% colspan="2" %)((( 56 -[[image:attach:DSC_0031.JPG||height="250"]] 57 -))) 58 -|=(% style="text-align: center;" %)((( 59 -large 60 -)))|=(% style="text-align: center;" %)((( 61 -small 62 -))) 63 -|(% style="text-align: center;" %)((( 64 -20 N 65 -)))|(% style="text-align: center;" %)((( 66 -- 67 -))) 68 -|(% style="text-align: center;" %)((( 69 -50 N 70 -)))|(% style="text-align: center;" %)((( 71 -- 72 -))) 73 -|(% style="text-align: center;" %)((( 74 -100 N 75 -)))|(% style="text-align: center;" %)((( 76 -- 77 -))) 78 -|(% style="text-align: center;" %)((( 79 -200 N 80 -)))|(% style="text-align: center;" %)((( 81 -200 N 82 -))) 83 -|(% style="text-align: center;" %)((( 84 -- 85 -)))|(% style="text-align: center;" %)((( 86 -500 N 87 -))) 88 -|(% style="text-align: center;" %)((( 89 -- 90 -)))|(% style="text-align: center;" %)((( 91 -1000 N 92 -))) 93 - 94 -== {{id name="Loadframe-Loadcellinstallation"/}}Load cell installation == 95 - 96 -== {{id name="Loadframe-Reference"/}}Reference == 97 - 98 -Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]] 99 - 100 100 \\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -3269754 831 +326975450 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/3269754 83/Load frame1 +https://confluence.desy.de/spaces/P5I/pages/326975450/Load frame