Changes for page Load frame

Last modified by fwilde on 2023/10/12 12:40

From version 9.1
edited by fwilde
on 2023/10/05 17:08
Change comment: There is no comment for this version
To version 5.1
edited by fwilde
on 2023/10/05 16:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,6 @@
1 1  == {{id name="Loadframe-Overview"/}}Overview ==
2 2  
3 -[[image:attach:DSC_0006.JPG||width="400"]]
3 +[[image:attach:DSC_0006.JPG||height="400"]]
4 4  
5 5  * Forces up to 1 kN (both pushing or pulling)
6 6  * Load cells 20N, 50N, 100N, 200N, 500N and 1000N available
... ... @@ -8,93 +8,8 @@
8 8  
9 9  == {{id name="Loadframe-Actuator"/}}Actuator ==
10 10  
11 -[[image:attach:DSC_0020.JPG||height="250"]][[image:attach:DSC_0021.JPG||height="250"]]
11 +The actuator is a customized PiMicos MA-35 actuator with a maximum load of 1000 N.
12 12  
13 -(% class="wrapped" %)
14 -|=(((
15 -PIMicos MA-35
16 -)))|=(((
17 -\\
18 -)))
19 -|(((
20 -max. load (in travel direction)
21 -)))|(((
22 -1000N
23 -)))
24 -|(((
25 -Travel range
26 -)))|(((
27 -? mm
28 -)))
29 -|(((
30 -min speed
31 -)))|(((
32 -? µm/s
33 -)))
34 -|(((
35 -max. speed
36 -)))|(((
37 -? µm/s
38 -)))
39 -|(((
40 -Step width
41 -)))|(((
42 -? µm
43 -)))
44 -|(((
45 -Thread
46 -)))|(((
47 -M8 x 0.5 ???
48 -)))
13 +More information: Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]]
49 49  
50 -== {{id name="Loadframe-Loadcells"/}}Load cells ==
51 -
52 -Two types of load cells are available with different diameters with the following force range
53 -
54 -(% class="relative-table wrapped" style="width: 19.0161%;" %)
55 -|(% colspan="2" %)(((
56 -[[image:attach:DSC_0031.JPG||height="250"]]
57 -)))
58 -|=(% style="text-align: center;" %)(((
59 -large
60 -)))|=(% style="text-align: center;" %)(((
61 -small
62 -)))
63 -|(% style="text-align: center;" %)(((
64 -20 N
65 -)))|(% style="text-align: center;" %)(((
66 --
67 -)))
68 -|(% style="text-align: center;" %)(((
69 -50 N
70 -)))|(% style="text-align: center;" %)(((
71 --
72 -)))
73 -|(% style="text-align: center;" %)(((
74 -100 N
75 -)))|(% style="text-align: center;" %)(((
76 --
77 -)))
78 -|(% style="text-align: center;" %)(((
79 -200 N
80 -)))|(% style="text-align: center;" %)(((
81 -200 N
82 -)))
83 -|(% style="text-align: center;" %)(((
84 --
85 -)))|(% style="text-align: center;" %)(((
86 -500 N
87 -)))
88 -|(% style="text-align: center;" %)(((
89 --
90 -)))|(% style="text-align: center;" %)(((
91 -1000 N
92 -)))
93 -
94 -== {{id name="Loadframe-Loadcellinstallation"/}}Load cell installation ==
95 -
96 -== {{id name="Loadframe-Reference"/}}Reference ==
97 -
98 -Moosmann et al. "A load frame for in situ tomography at PETRA III", Proc. SPIE 11113, Developments in X-Ray Tomography XII, 1111318 (2019); [[https:~~/~~/doi.org/10.1117/12.2530445>>url:https://doi.org/10.1117/12.2530445||rel="nofollow" shape="rect"]]
99 -
100 100  \\
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -326975483
1 +326975450
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/P5I/pages/326975483/Load frame
1 +https://confluence.desy.de/spaces/P5I/pages/326975450/Load frame