Changes for page IDL cheat sheet
Last modified by fwilde on 2025/03/28 19:55
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,7 @@ 31 31 relative [ mm ] 32 32 ))) 33 33 |((( 34 -##**s_pos, 1**## 34 +##**s_pos_lateral, 1**## 35 35 )))|((( 36 36 move sample stage in x-direction by 1 mm, regardless of position of rotation axis 37 37 )))|((( ... ... @@ -125,9 +125,9 @@ 125 125 move sample to "change" position 126 126 ))) 127 127 |((( 128 -##**set_s_in_pos (, 0)**##128 +##**set_s_in_pos, 0**## 129 129 )))|((( 130 -set s_in position to current stage position, or optionally to e.g.0.0 mm130 +set s_in position to 0.0 mm 131 131 ))) 132 132 |((( 133 133 ##**set_s_out_dist, 10**## ... ... @@ -144,16 +144,14 @@ 144 144 description 145 145 ))) 146 146 |((( 147 -##**save_magn_set(, name_add) 148 -**## 147 +##**save_magn_set, 'dmm_11000ev_cmos_10x'**## 149 149 )))|((( 150 -save current magnification set , optionally add something to the automatically generated name149 +save current magnification set 151 151 ))) 152 152 |((( 153 -##**restore_magn_set(, name) 154 -**## 152 +##**restore_magn_set, 'dmm_11000ev_cmos_10x'**## 155 155 )))|((( 156 -restore lastmagnification set,or optionally load a filewitha specificname154 +restore magnification set with the name 'dmm_11000ev_cmos_10x' 157 157 ))) 158 158 159 159 == {{id name="IDLcheatsheet-Detectorpositioning"/}}Detector positioning == ... ... @@ -167,23 +167,23 @@ 167 167 motion 168 168 ))) 169 169 |((( 170 -##** o_ccd_dist, 5**##168 +##**pressure_on**## 171 171 )))|((( 172 - move detectorinydirection relativeby 5mm170 +enable detector y movement 173 173 )))|((( 174 - relative [ mm ]172 +\\ 175 175 ))) 176 176 |((( 177 -##** goto_o_ccd_dist,30**##175 +##**o_ccd_dist, 5**## 178 178 )))|((( 179 -move detector in y direction absoilute to 30 mm177 +move detector in y direction 180 180 )))|((( 181 - \\179 +relative [ mm ] 182 182 ))) 183 183 |((( 184 -##**p os_o_ccd_dist()**##182 +##**pressure_off**## 185 185 )))|((( 186 - returncurrentof theamerastagedistance184 +disable detector movement 187 187 )))|((( 188 188 \\ 189 189 ))) ... ... @@ -289,7 +289,7 @@ 289 289 absolute [ deg ] 290 290 ))) 291 291 |((( 292 -##**reflex_opt _single**##290 +##**reflex_opt**## 293 293 )))|((( 294 294 move 2nd crystal pitch to optimal flux position 295 295 )))|((( ... ... @@ -387,17 +387,17 @@ 387 387 prints an overview of the beamline interlock status 388 388 ))) 389 389 |((( 390 -##** oh_break_ics**##388 +##**ics_break_oh**## 391 391 )))|((( 392 392 closes all P05 beamshutters and breaks OH door interlock. P06 beamshutter must be closed for this command to work! 393 393 ))) 394 394 |((( 395 -##** eh1_break_ics**##393 +##**ics_break_eh1**## 396 396 )))|((( 397 397 closes EH1 beamshutter (and EH2 beamshutter if open) and breaks EH1 door interlock 398 398 ))) 399 399 |((( 400 -##** eh2_break_ics**##398 +##**ics_break_eh2**## 401 401 )))|((( 402 402 closes EH2 beshutter and breaks EH2 door interlock 403 403 )))
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 - 3658350541 +179783466 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/P5I/pages/ 365835054/IDL cheat sheet1 +https://confluence.desy.de/spaces/P5I/pages/179783466/IDL cheat sheet