Changes for page IDL cheat sheet

Last modified by fwilde on 2025/03/28 19:55

From version 57.1
edited by fwilde
on 2024/06/13 14:51
Change comment: There is no comment for this version
To version 49.1
edited by fwilde
on 2020/10/10 12:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,4 +1,4 @@
1 -== {{id name="IDLcheatsheet-eCoordinatesystem"/}}eCoordinate system ==
1 +== {{id name="IDLcheatsheet-Coordinatesystem"/}}Coordinate system ==
2 2  
3 3  Right-handed coordinate system with y-direction along the x-ray beam.
4 4  
... ... @@ -31,7 +31,7 @@
31 31  relative [ mm ]
32 32  )))
33 33  |(((
34 -##**s_pos, 1**##
34 +##**s_pos_lateral, 1**##
35 35  )))|(((
36 36  move sample stage in x-direction by 1 mm, regardless of position of rotation axis
37 37  )))|(((
... ... @@ -125,9 +125,9 @@
125 125  move sample to "change" position
126 126  )))
127 127  |(((
128 -##**set_s_in_pos(, 0)**##
128 +##**set_s_in_pos, 0**##
129 129  )))|(((
130 -set s_in position to current stage position, or optionally to e.g. 0.0 mm
130 +set s_in position to 0.0 mm
131 131  )))
132 132  |(((
133 133  ##**set_s_out_dist, 10**##
... ... @@ -144,16 +144,14 @@
144 144  description
145 145  )))
146 146  |(((
147 -##**save_magn_set(, name_add)
148 -**##
147 +##**save_magn_set, 'dmm_11000ev_cmos_10x'**##
149 149  )))|(((
150 -save current magnification set, optionally add something to the automatically generated name
149 +save current magnification set
151 151  )))
152 152  |(((
153 -##**restore_magn_set(, name)
154 -**##
152 +##**restore_magn_set, 'dmm_11000ev_cmos_10x'**##
155 155  )))|(((
156 -restore last magnification set, or optionally load a file with a specific name
154 +restore magnification set with the name 'dmm_11000ev_cmos_10x'
157 157  )))
158 158  
159 159  == {{id name="IDLcheatsheet-Detectorpositioning"/}}Detector positioning ==
... ... @@ -167,23 +167,23 @@
167 167  motion
168 168  )))
169 169  |(((
170 -##**o_ccd_dist, 5**##
168 +##**pressure_on**##
171 171  )))|(((
172 -move detector in y direction relative by 5 mm
170 +enable detector y movement
173 173  )))|(((
174 -relative [ mm ]
172 +\\
175 175  )))
176 176  |(((
177 -##**goto_o_ccd_dist, 30**##
175 +##**o_ccd_dist, 5**##
178 178  )))|(((
179 -move detector in y direction absoilute to 30 mm
177 +move detector in y direction
180 180  )))|(((
181 -\\
179 +relative [ mm ]
182 182  )))
183 183  |(((
184 -##**pos_o_ccd_dist()**##
182 +##**pressure_off**##
185 185  )))|(((
186 -return current of the camera stage distance
184 +disable detector movement
187 187  )))|(((
188 188  \\
189 189  )))
... ... @@ -254,59 +254,8 @@
254 254  save a as 32-bit float tiff in /gpfs/...
255 255  )))
256 256  
257 -== {{id name="IDLcheatsheet-Macrosmotion+images"/}}Macros motion  + images ==
255 +\\
258 258  
259 -These macros make images with predefined and internally saved values (like exposure time or display scale). Some move an axis first and then make an image (again with internally saved options likeexposure time, and image type). **Use these macros to quickly align you samples.**
260 -
261 -(% class="relative-table wrapped" style="width: 114.69%;" %)
262 -|=(((
263 -IDL command
264 -)))|=(((
265 -description
266 -)))
267 -|(((
268 -**{{code language="none"}}qt (, t=100, scale=[0,4096]){{/code}}**
269 -)))|(((
270 -Quick **transmission** image at the current position. Options: set new exposure time, set new scale for image display,
271 -)))
272 -|(((
273 -**{{code language="none"}}qa (, t=100, scale=[0,2], /ref, /here){{/code}}**
274 -)))|(((
275 -Quick **absorption** image at s_in position. Options: set new exposure time, set new scale for image display, make new reference image, make image at current position.
276 -)))
277 -|(((
278 -**{{code language="none"}}qp (, t=100, scale=[0,2], /ref, /here){{/code}}**
279 -)))|(((
280 -Quick **phase** image at s_in position. Options: set new exposure time, set new scale for image display, make new reference image, make image at current position
281 -)))
282 -|(((
283 -**{{code language="none"}}qr (, t=100, scale=[0,4096]){{/code}}
284 -**
285 -)))|(((
286 -Quick **reference image**. Options: set new exposure time,  set new scale for image display,
287 -)))
288 -|(((
289 -**{{code language="none"}}side, 90 (, t=100, /ref, /rel, /here, imgtype='a') {{/code}}**
290 -)))|(((
291 -**Rotate** (absolute degrees) and make an image at the new position. Options: set new exposure time, make new reference image, make image at current position, set image type ('a': absorption, 't': transmission, 'p' phase)
292 -)))
293 -|(((
294 -**{{code language="none"}}sshift, 2 (, t=100, /ref, /here, imgtype='a'){{/code}}**
295 -)))|(((
296 -Move **sample stage laterally** (relative, mm) and make an image at the new position. Options: set exposure time, make new reference image, , make image at current position, set image type ('a': absorption, 't': transmission, 'p' phase)
297 -)))
298 -|(((
299 -##**sz, 2 (, t=100, /ref, /here, imgtype='a')**##
300 -)))|(((
301 -Move **rotation stage up or down** (relative, mm) and make an image at the new position. Options: set exposure time, make reference image, make image at current position, set image type ('a': absorption, 't': transmission, 'p' phase)
302 -)))
303 -|(((
304 -**{{code language="none"}}zx, 2 (, t=100, /ref, /here, imgtype='a'){{/code}}
305 -**
306 -)))|(((
307 -Move **rotation stage left or right** (relative, mm) and make an image at the new position. Options: set exposure time, make reference image, make image at current position, set image type ('a': absorption, 't': transmission, 'p' phase)
308 -)))
309 -
310 310  \\
311 311  
312 312  {{info title="Monochromator positioning"}}
... ... @@ -340,7 +340,7 @@
340 340  absolute [ deg ]
341 341  )))
342 342  |(((
343 -##**reflex_opt_single**##
290 +##**reflex_opt**##
344 344  )))|(((
345 345  move 2nd crystal pitch to optimal flux position
346 346  )))|(((
... ... @@ -438,68 +438,17 @@
438 438  prints an overview of the beamline interlock status
439 439  )))
440 440  |(((
441 -##**oh_break_ics**##
388 +##**ics_break_oh**##
442 442  )))|(((
443 443  closes all P05 beamshutters and breaks OH door interlock. P06 beamshutter must be closed for this command to work!
444 444  )))
445 445  |(((
446 -##**eh1_break_ics**##
393 +##**ics_break_eh1**##
447 447  )))|(((
448 448  closes EH1 beamshutter (and EH2 beamshutter  if open) and breaks EH1 door interlock
449 449  )))
450 450  |(((
451 -##**eh2_break_ics**##
398 +##**ics_break_eh2**##
452 452  )))|(((
453 453  closes EH2 beshutter and breaks EH2 door interlock
454 454  )))
455 -
456 -== {{id name="IDLcheatsheet-Helpermacros"/}}Helper macros ==
457 -
458 -The helper macros may help to align a sample quickly. Mainly, these are motion commands which subsequently make an image with predefined values.
459 -
460 -(% class="wrapped" %)
461 -|=(((
462 -IDL command
463 -)))|=(((
464 -description
465 -)))
466 -|(((
467 -helper_object, /info
468 -)))|(((
469 -show predefined values
470 -)))
471 -|(((
472 -\\
473 -)))|(((
474 -\\
475 -)))
476 -|(((
477 -\\
478 -)))|(((
479 -\\
480 -)))
481 -|(((
482 -\\
483 -)))|(((
484 -\\
485 -)))
486 -|(((
487 -\\
488 -)))|(((
489 -\\
490 -)))
491 -|(((
492 -\\
493 -)))|(((
494 -\\
495 -)))
496 -|(((
497 -\\
498 -)))|(((
499 -\\
500 -)))
501 -|(((
502 -\\
503 -)))|(((
504 -\\
505 -)))
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -365835135
1 +179783466
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/P5I/pages/365835135/IDL cheat sheet
1 +https://confluence.desy.de/spaces/P5I/pages/179783466/IDL cheat sheet