... ... @@ -2,10 +2,8 @@
2 2  
3 3  There are 2 mirror protection servers ( one for the 2 mirrors in the tunnel and one for the experimental hall)
4 4  
5 -\\
5 +[[image:attach:Clipboard12.jpg||thumbnail="true" height="250"]]
6 6  
7 -[[image:attach:image2020-9-25_17-12-45.png||width="400"]] [[image:attach:image2021-2-10_18-8-7.png||width="400"]]
8 -
9 9  \\
10 10  
11 11  The server checks that for the set wavelength the coating of the mirrors is appropriate. IF NOT the tunnel protection server will close PS1 and the hall protection server will close PS2. The closing is combined with a warning indicating the problem.
... ... @@ -14,43 +14,14 @@
14 14  
15 15  If everything is set properly and the possible wavelength is  < 5.5 nm  (checked by electron energy) this will be indicated in the tunnel view
16 16  
17 -[[image:attach:image2021-2-10_18-4-17.png||height="150"]]
15 +[[image:attach:image2020-9-25_17-6-26.png||height="150"]]
18 18  
19 19  \\
20 20  
21 -If the protection server is not active this will be indicated when PS1 is closed [[image:attach:image2021-2-10_17-55-57.png||thumbnail="true" width="150"]]
19 +If the protection server is not active this will be indicated when PS1 is closed [[image:attach:image2020-9-25_17-8-9.png||thumbnail="true" height="50"]] and even more if it is open[[image:attach:image2020-9-25_17-7-58.png||thumbnail="true" height="50"]]
22 22  
23 -and even more if it is open[[image:attach:image2021-2-10_17-54-19.png||thumbnail="true" width="150"]]
24 -
25 -If the protection server, wavelength server or mirror moving server is unavailable or has some errors the message[[image:attach:image2021-2-10_17-51-59.png||thumbnail="true" width="150"]] will be displayed. IN the right lower corner it also shows the reason. clicking on the warning one gets to the protection overview:
26 -
27 27  \\
28 28  
29 -[[image:attach:image2021-2-10_18-6-39.png||height="250"]]
23 +If the protection server, wavelength server or mirror moving server is unavailable or has some errors the message  [[image:attach:image2020-9-25_17-9-19.png||thumbnail="true" height="50"]] will be displayed.
30 30  
31 31  \\
32 -
33 -\\
34 -
35 -== Expert stuff: ==
36 -
37 -FLASH.UTIL/MIRROR.PROTECTION/FL2.HALL/ACTION indicates actions the server will do, 0=ok, >0 will be close
38 -
39 -0 = ok
40 -1 = closing absorbler
41 -2 = absorber already closed
42 -3 = absorber control disabled
43 -
44 -\\
45 -
46 -\\
47 -
48 -If parameters like TTF2.FEEDBACK/FL2.WAVELENGTHCONTROL/FLASH2/WAVELENGTH.USED  are not readable  → generate warning
49 -
50 -\\
51 -
52 -warning conditions:
53 -
54 -[[image:attach:2021-02-10 17_48_21-XFCE.png||thumbnail="true" height="250"]]
55 -
56 -\\